Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.

P D Wimberley, K Grønlund Pedersen, J Olsson, O Siggaard-Andersen.   

Abstract

Transcutaneous carbon dioxide tension (tc-pco2) at 37, 39, 41, 43, and 45 degrees C, and transcutaneous oxygen tension (tc-po2) at 41, 43, and 45 degrees C were measured simultaneously in 10 healthy adults during hyperventilation and inhalation of O2/CO2 gas. Nine electrodes were applied to each subject: Five CO2 electrodes, one O2 electrode, and three combined O2/CO2 electrodes. The CO2 electrodes had negligible temperature coefficients in the calibration gases, but the O2 electrodes showed an increase in po2 of 4.5% per degree C. With skin application, tc-pco2 increased approximately 4% per degrees C between 37 and 45 degrees C, which is close to the anaerobic temperature coefficient of pco2 in blood. The tc-po2 increases on the skin with increasing temperature appeared to be more dependent on changes in blood flow in skin, but in the temperature range 43 to 45 degrees C, tc-po2 showed the expected decrease in the temperature coefficient with increasing po2. The correlation between transcutaneous and capillary pco2 was close at all transcutaneous electrode temperatures, even 37 degrees C, provided the skin was preheated (via the electrode) to 45 degrees C. For tc-po2, an electrode temperature of at least 43 degrees C was necessary to produce a reasonable correlation between tc-po2 and capillary po2. The combined O2/CO2 electrodes measured slightly higher pco2 values than the single CO2 electrodes, but there were no differences in po2 readings, stabilization time, imprecision, or electrode drift between the two electrode types. The imprecision (CV, %) of tc-pco2 and tc-po2 measurements was approximately twice that of the corresponding capillary blood-gas measurements.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3930089

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Comparison of ear and chest probes in transcutaneous carbon dioxide pressure measurements during general anesthesia in adults.

Authors:  Tomoki Nishiyama; Yumiko Kohno; Keiko Koishi
Journal:  J Clin Monit Comput       Date:  2011-10-19       Impact factor: 2.502

2.  Dynamic model of oxygen transport for transcutaneous PO2 analysis.

Authors:  A Talbot; M R Neuman; G M Saidel; E Jacobsen
Journal:  Ann Biomed Eng       Date:  1996 Mar-Apr       Impact factor: 3.934

3.  Comparison of arterial, end-tidal and transcutaneous PCO2 during moderate exercise and external CO2 loading in humans.

Authors:  U Hoffmann; D Essfeld; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

4.  Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension.

Authors:  Tomoki Nishiyama; Shinji Nakamura; Koichi Yamashita
Journal:  J Anesth       Date:  2006       Impact factor: 2.078

5.  Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension.

Authors:  Line C Sørensen; Lene Brage-Andersen; Gorm Greisen
Journal:  Scand J Clin Lab Invest       Date:  2011-07-06       Impact factor: 1.713

Review 6.  Carbon Dioxide Sensing-Biomedical Applications to Human Subjects.

Authors:  Emmanuel Dervieux; Michaël Théron; Wilfried Uhring
Journal:  Sensors (Basel)       Date:  2021-12-28       Impact factor: 3.576

7.  Applicability of Transcutaneous Oxygen Tension Measurement in the Assessment of Chronic Limb-Threatening Ischemia.

Authors:  Bernard Leenstra; Joep Wijnand; Bart Verhoeven; Olivier Koning; Martin Teraa; Marianne C Verhaar; Gert J de Borst
Journal:  Angiology       Date:  2019-08-06       Impact factor: 3.619

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.