Literature DB >> 3920683

Electron contamination from different materials in high energy photon beams.

B Nilsson.   

Abstract

Relative lateral electron surface dose distributions from filters and air in high energy photon beams were determined using the Fermi-Eyges theory of multiple scattering. The model includes transmission and angular scattering in materials and in air. Backscatter from the phantom was also estimated. The variation of surface dose with different parameters such as atomic number, thickness and position of material, field size and photon energy was investigated. The calculated data show good agreement with experiment. For 60Co gamma rays, electron filters of medium atomic number give the lowest surface dose, whereas for higher energies a low to medium atomic number material should be used, especially for short material-phantom distances and large field sizes. The contribution to surface dose can be reduced by over 30% by placing a thin foil of high atomic number after a low to medium atomic number filter, thus scattering some electrons from the beam. For 60Co gamma rays the air is often the dominant source of contaminating electrons because of high multiple scatter loss at this energy, while for higher photon energies the beam flattening filter is the main electron source because of the small emission angle of the electrons and the small scattering power at high energies.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3920683     DOI: 10.1088/0031-9155/30/2/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams.

Authors:  Tülay P Meydanci; Gönül Kemikler
Journal:  Radiat Med       Date:  2008-11-22

2.  [Optimization of photon dose distributions with compensation].

Authors:  C Skalsky; L Bogner; M Herbst
Journal:  Strahlenther Onkol       Date:  1998-05       Impact factor: 3.621

3.  Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams.

Authors:  Hatice Bilge; Nurdan Ozbek; Murat Okutan; Aydin Cakir; Hilal Acar
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

4.  Projection imaging of photon beams by the Čerenkov effect.

Authors:  Adam K Glaser; Scott C Davis; David M McClatchy; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Surface buildup dose dependence on photon field delivery technique for IMRT.

Authors:  Shigeru Yokoyama; Peter L Roberson; Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2004-04-01       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.