Literature DB >> 3908654

Comparison of accuracy of multiunit one-piece castings.

B E Schiffleger, G J Ziebert, V B Dhuru, W A Brantley, K Sigaroudi.   

Abstract

An investigation was conducted to evaluate the accuracy of one-piece castings of FPDs consisting of three, four, and five units with a ceramometal alloy cast in a large circular ring. A three-piece aluminum mold with stainless steel dies simulating the various lengths of the FPDs was used. A total of 18 castings, six castings for each FPD, were fabricated. Marginal discrepancies of the castings on the dies and the length of the castings were compared before and after sectioning the castings at the connectors. The following conclusions were drawn from the study. Seating of the castings improved approximately 50% after sectioning, which indicates that the castings were distorted. The distortion was a three-dimensional phenomenon, with the greatest discrepancy on the mesiogingival surface of the anterior retainer and on the distolingual surface of the posterior retainer. The distortion was least for the three-unit FPDs and greatest for the five-unit FPDs. The lingual-facial diameter of the castings at the gingival axial line angle was significantly larger than the dies in most cases. The mesiodistal diameter of the castings at the gingival axial line angle was smaller than that of the dies but was only significant with the three-unit FPDs. Although the castings were slightly oversized or undersized, the primary reason the castings did not seat was warpage.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3908654     DOI: 10.1016/0022-3913(85)90467-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Computer-aided flapless implant surgery and immediate loading. A technical note.

Authors:  Alfonso Baruffaldi; Pier Paolo Poli; Andrea Baruffaldi; Lorenzo Giberti; Maurizio Pigozzo; Carlo Maiorana
Journal:  Oral Maxillofac Surg       Date:  2016-04-05

2.  Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins.

Authors:  Emanuely Ronconi da Fonseca; Paula Pereira Santana; Anuar Antonio Xible; Donald A Curtis; Stefania Carvalho Kano
Journal:  Int J Implant Dent       Date:  2019-09-18

3.  The influence of screw type, alloy and cylinder position on the marginal fit of implant frameworks before and after laser welding.

Authors:  Daniela Castilio; Ana Paula Ribeiro do Vale Pedreira; Paulo Henrique Orlato Rossetti; Leylha Maria Nunes Rossetti; Wellington Cardoso Bonachela
Journal:  J Appl Oral Sci       Date:  2006-04       Impact factor: 2.698

4.  Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible.

Authors:  Kyung-Hoi Heo; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.