Literature DB >> 3905849

autoSCAN-4 system for identification of gram-negative bacilli.

D L Rhoden, P B Smith, C N Baker, B Schable.   

Abstract

A production model of the autoSCAN-4 system (American MicroScan, Inc., Mahwah, N.J.) was tested with not more than 11 strains each of 73 groups or species of gram-negative bacilli from various Centers for Disease Control culture collections. The strains included typical and atypical strains of enteric fermenters, nonenteric fermenters, and nonfermenters. The autoSCAN-4 system identified 95.3% of all 405 cultures accurately: 95.4% of 307 members of the family Enterobacteriaceae, 96.6% of 29 nonenteric fermenters, and 94.2% of 69 nonfermenters. Manual readings of the same trays provided essentially the same results, with a maximum change of only +1.6% identification accuracy of members of the Enterobacteriaceae. These data were obtained by all required additional tests, including serology and computer consultation when indicated. Only 19 of the cultures tested were misidentified. These were distributed randomly throughout the various groups and species except that Edwardsiella tarda was usually missed because of poor H2S reactions in the test medium. Of six Yersinia enterocolitica isolates, two were not identified. Only one nonenteric fermenter, a Pasteurella sp., and four nonfermenters (three Pseudomonas sp. and one Centers for Disease Control group Ve-2) were misidentified.

Entities:  

Mesh:

Year:  1985        PMID: 3905849      PMCID: PMC271851          DOI: 10.1128/jcm.22.6.915-918.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

Review 1.  Automated systems for identification of microorganisms.

Authors:  C E Stager; J R Davis
Journal:  Clin Microbiol Rev       Date:  1992-07       Impact factor: 26.132

2.  Evaluation of the autoSCAN-W/A system for rapid (2-hour) identification of members of the family Enterobacteriaceae.

Authors:  C M O'Hara; J M Miller
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

3.  Reevaluation of the API 20E identification system versus conventional biochemicals for identification of members of the family Enterobacteriaceae: a new look at an old product.

Authors:  C M O'Hara; D L Rhoden; J M Miller
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

4.  Evaluation of autoSCAN-W/A automated microbiology system for the identification of non-glucose-fermenting gram-negative bacilli.

Authors:  F C Tenover; T S Mizuki; L G Carlson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

5.  Agreement between visual and automated UniScept API readings.

Authors:  C M O'Hara; D L Rhoden; P B Smith
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

6.  Evaluation of the 4-hour RapID NF Plus method for identification of 345 gram-negative nonfermentative rods.

Authors:  T T Kitch; M R Jacobs; P C Appelbaum
Journal:  J Clin Microbiol       Date:  1992-05       Impact factor: 5.948

7.  Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram-negative bacilli.

Authors:  A Robinson; Y S McCarter; J Tetreault
Journal:  J Clin Microbiol       Date:  1995-02       Impact factor: 5.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.