Literature DB >> 3885869

Inspiratory time and tidal volume during intermittent positive pressure ventilation.

D Field, A D Milner, I E Hopkin.   

Abstract

We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

Mesh:

Year:  1985        PMID: 3885869      PMCID: PMC1777205          DOI: 10.1136/adc.60.3.259

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  3 in total

1.  Effect of alterations in mechanical ventilator settings on pulmonary gas exchange in hyaline membrane disease.

Authors:  E O Reynolds
Journal:  Arch Dis Child       Date:  1971-04       Impact factor: 3.791

2.  High and conventional rates of positive pressure ventilation.

Authors:  D Field; A D Milner; I E Hopkin
Journal:  Arch Dis Child       Date:  1984-12       Impact factor: 3.791

3.  Nebulised therapy in acute severe bronchiolitis in infancy.

Authors:  G M Stokes; A D Milner; I G Hodges; R L Henry; M C Elphick
Journal:  Arch Dis Child       Date:  1983-04       Impact factor: 3.791

  3 in total
  7 in total

1.  International randomised controlled trial of patient triggered ventilation in neonatal respiratory distress syndrome.

Authors:  J H Baumer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-01       Impact factor: 5.747

2.  The effect of changes in inspiratory time on neonatal triggered ventilation.

Authors:  C J Upton; A D Milner; G M Stokes
Journal:  Eur J Pediatr       Date:  1990-06       Impact factor: 3.183

3.  Mechanical ventilation of the newborn.

Authors:  W Tarnow-Mordi; A Wilkinson
Journal:  Br Med J (Clin Res Ed)       Date:  1986-03-01

4.  Randomised controlled trial of two methods of weaning from high frequency positive pressure ventilation.

Authors:  A Greenough; J Pool; H Gamsu
Journal:  Arch Dis Child       Date:  1989-06       Impact factor: 3.791

5.  Manipulation of ventilator settings to prevent active expiration against positive pressure inflation.

Authors:  D Field; A D Milner; I E Hopkin
Journal:  Arch Dis Child       Date:  1985-11       Impact factor: 3.791

6.  High frequency ventilation in the neonatal period.

Authors:  A Greenough; A D Milner
Journal:  Eur J Pediatr       Date:  1987-09       Impact factor: 3.183

Review 7.  Respiratory support using patient triggered ventilation in the neonatal period.

Authors:  A Greenough; A D Milner
Journal:  Arch Dis Child       Date:  1992-01       Impact factor: 3.791

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.