The effect of changes in inspiratory time on neonatal triggered ventilation.

C J Upton1, A D Milner, G M Stokes.   

Abstract

Nine preterm infants with hyaline membrane disease were studied using a ventilator triggered from abdominal movement. It was possible to alter respiratory rate over a short space of time by adjustments of the inspiratory time setting. There was a marked inverse relationship between inspiratory time and both ventilator and baby's respiratory rate--mean baby respiratory rate was 62 breaths/min at an inspiratory time of 0.2 s and 45 breaths/min at 0.8 s. This drop was statistically significant (P less than 0.005). Mean tidal volume changed little over this range. This interaction meant that mean minute ventilation was optimal at inspiratory times of 0.2 to 0.4 s, being 269 and 258 ml/kg per minute, respectively, but at 0.8 s fell to 213 ml/kg per minute (P less than 0.05).

Entities:  

Mesh:

Year:  1990        PMID: 2373119     DOI: 10.1007/bf02034755

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  9 in total

1.  Patient triggered ventilation in premature neonates.

Authors:  A Mehta
Journal:  Arch Dis Child       Date:  1988-09       Impact factor: 3.791

2.  Synchronous mechanical ventilation of the neonate.

Authors:  M South; C J Morley
Journal:  Arch Dis Child       Date:  1986-12       Impact factor: 3.791

3.  Manipulation of ventilator settings to prevent active expiration against positive pressure inflation.

Authors:  D Field; A D Milner; I E Hopkin
Journal:  Arch Dis Child       Date:  1985-11       Impact factor: 3.791

4.  Patient-triggered ventilation prevents pneumothorax in premature babies.

Authors:  R D Clifford; G Whincup; R Thomas
Journal:  Lancet       Date:  1988-03-05       Impact factor: 79.321

5.  Patient-triggered ventilation in the newborn.

Authors:  A Mehta; B M Wright; K Callan; T E Stacey
Journal:  Lancet       Date:  1986-07-05       Impact factor: 79.321

6.  Interaction of spontaneous respiration with artificial ventilation in preterm babies.

Authors:  A Greenough; C Morley; J Davis
Journal:  J Pediatr       Date:  1983-11       Impact factor: 4.406

7.  Inspiratory time and tidal volume during intermittent positive pressure ventilation.

Authors:  D Field; A D Milner; I E Hopkin
Journal:  Arch Dis Child       Date:  1985-03       Impact factor: 3.791

8.  Patient triggered ventilation in premature neonates.

Authors:  A Greenough; F Greenall
Journal:  Arch Dis Child       Date:  1988-01       Impact factor: 3.791

9.  Neonatal patient triggered ventilation.

Authors:  A Greenough; J Pool
Journal:  Arch Dis Child       Date:  1988-04       Impact factor: 3.791

  9 in total
  8 in total

1.  International randomised controlled trial of patient triggered ventilation in neonatal respiratory distress syndrome.

Authors:  J H Baumer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-01       Impact factor: 5.747

Review 2.  New modes of mechanical ventilation in the preterm newborn: evidence of benefit.

Authors:  Nelson Claure; Eduardo Bancalari
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-09-05       Impact factor: 5.747

3.  Patient triggered ventilation using a flow triggered system.

Authors:  M F Hird; A Greenough
Journal:  Arch Dis Child       Date:  1991-10       Impact factor: 3.791

4.  Non-invasive neurally adjusted ventilatory assist in rabbits with acute lung injury.

Authors:  Jennifer Beck; Lukas Brander; Arthur S Slutsky; Maureen C Reilly; Michael S Dunn; Christer Sinderby
Journal:  Intensive Care Med       Date:  2007-10-25       Impact factor: 17.440

5.  Evaluation of triggering systems for patient triggered ventilation for neonates ventilator-dependent beyond 10 days of age.

Authors:  V Chan; A Greenough
Journal:  Eur J Pediatr       Date:  1992-11       Impact factor: 3.183

6.  Randomised controlled trial of weaning by patient triggered ventilation or conventional ventilation.

Authors:  V Chan; A Greenough
Journal:  Eur J Pediatr       Date:  1993-01       Impact factor: 3.183

Review 7.  Long versus short inspiratory times in neonates receiving mechanical ventilation.

Authors:  C O F Kamlin; P G Davis
Journal:  Cochrane Database Syst Rev       Date:  2004-10-18

Review 8.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.