Literature DB >> 3873524

Dynamic positron computed tomography of the heart with a high sensitivity positron camera and nitrogen-13 ammonia.

N Tamaki, M Senda, Y Yonekura, H Saji, S Kodama, Y Konishi, T Ban, H Kambara, C Kawai, K Torizuka.   

Abstract

Dynamic positron computed tomography (PCT) of the heart was performed with a high-sensitivity, whole-body multislice PCT device and [13N]ammonia. Serial 15-sec dynamic study immediately after i.v. [13N]ammonia injection showed blood pool of the ventricular cavities in the first scan and myocardial images from the third scan in normal cases (n = 4). In patients with myocardial infarction (n = 8) and mitral valve disease (n = 2), tracer washout from the lung and myocardial peak time tended to be longer, suggesting presence of pulmonary congestion. PCT delineated tracer retention in the dorsal part of the lung. Serial 5-min late dynamic study in nine cases showed gradual increase in myocardial activity for 30 min in all normal segments and 42% of infarct segments, while less than 13% activity increase was observed in 50% of infarct segments. Thus, serial dynamic PCT with [13N]ammonia assessing tracer kinetics in the heart and lung is a valuable adjunct to the static myocardial perfusion imaging for evaluation of various cardiac disorders.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3873524

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

Review 1.  An overview of radiotracers in nuclear cardiology.

Authors:  W Acampa; C Di Benedetto; A Cuocolo
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

Review 2.  Management decisions in valvular heart disease: the role of radionuclide-based assessment of ventricular function and performance.

Authors:  J S Borer; D Wencker; C Hochreiter
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

3.  Myocardial positron computed tomography with 13N-ammonia at rest and during exercise.

Authors:  N Tamaki; Y Yonekura; M Senda; S A Kureshi; H Saji; S Kodama; Y Konishi; T Ban; H Kambara; C Kawai
Journal:  Eur J Nucl Med       Date:  1985

4.  Fast dynamic study in cardiac positron CT using 13N-ammonia in man.

Authors:  K Yoshida; T Himi; M Shukuya; Y Masuda; Y Inagaki; M Endo; N Fukuda; T Yamasaki; T Iinuma; Y Tateno
Journal:  Eur J Nucl Med       Date:  1986

5.  Dynamic positron emission tomography with 13N-ammonia in liver tumors.

Authors:  T Shibata; K Yamamoto; N Hayashi; Y Yonekura; T Nagara; H Saji; T Mukai; J Konishi
Journal:  Eur J Nucl Med       Date:  1988
  5 in total