Literature DB >> 3490978

Fast dynamic study in cardiac positron CT using 13N-ammonia in man.

K Yoshida, T Himi, M Shukuya, Y Masuda, Y Inagaki, M Endo, N Fukuda, T Yamasaki, T Iinuma, Y Tateno.   

Abstract

Fast dynamic studies with positron computed tomography (PCT) of the heart have been relatively few because of the technical limitations of prevalently used PCT devices. In the present study, we used a high-sensitivity, whole-body multislice PCT device (POSITOLOGICA-II) and performed serial 6-s PCT scans after the intravenous bolus injection of 13N-ammonia in 15 cardiac patients and 5 normal subjects. On the first image (0-6 s), 13N activity was primarily in the right atrium and ventricle. On the third image (12-18 s), it was primarily in the left atrium and ventricle. These blood-pool images permit evaluation of size and configuration of ventricles and atria in cardiac patients and normal subjects. Clearance of 13N activity in the blood pools and lungs occurred primarily during the 1st min. Thereafter, the myocardial images were delineated. In patients with heart failure, delayed clearance of the tracer from the blood pools and lungs was observed. The results indicate that initial passage of the tracer through the heart can be observed with the use of fast dynamic PCT.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3490978     DOI: 10.1007/BF00251974

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Quantitation in positron emission computed tomography: 1. Effect of object size.

Authors:  E J Hoffman; S C Huang; M E Phelps
Journal:  J Comput Assist Tomogr       Date:  1979-06       Impact factor: 1.826

2.  Dynamic positron computed tomography of the heart with a high sensitivity positron camera and nitrogen-13 ammonia.

Authors:  N Tamaki; M Senda; Y Yonekura; H Saji; S Kodama; Y Konishi; T Ban; H Kambara; C Kawai; K Torizuka
Journal:  J Nucl Med       Date:  1985-06       Impact factor: 10.057

3.  Measurement of regional myocardial blood flow with N-13 ammonia and positron-emission tomography in intact dogs.

Authors:  A Shah; H R Schelbert; M Schwaiger; E Henze; H Hansen; C Selin; S C Huang
Journal:  J Am Coll Cardiol       Date:  1985-01       Impact factor: 24.094

4.  [A dynamic study of intravenously administered 13NH3 with positron computed tomography: investigation of normal subjects and patients with myocardial infarction].

Authors:  K Yoshida; H Imai; M Shukuya; Y Masuda; Y Inagaki; F Shishido; S Tamachi; H Ikehira; T Yamasaki; Y Tateno
Journal:  Kokyu To Junkan       Date:  1984-07

5.  Special characteristics and potential for dynamic function studies with PET.

Authors:  M M Ter-Pogossian
Journal:  Semin Nucl Med       Date:  1981-01       Impact factor: 4.446

6.  Regional assessment of myocardial metabolic integrity in vivo by positron-emission tomography with 11C-labeled palmitate.

Authors:  M M Ter-Pogossian; M S Klein; J Markham; R Roberts; B E Sobel
Journal:  Circulation       Date:  1980-02       Impact factor: 29.690

7.  N-13 ammonia as an indicator of myocardial blood flow.

Authors:  H R Schelbert; M E Phelps; S C Huang; N S MacDonald; H Hansen; C Selin; D E Kuhl
Journal:  Circulation       Date:  1981-06       Impact factor: 29.690

8.  Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography.

Authors:  H R Schelbert; G Wisenberg; M E Phelps; K L Gould; E Henze; E J Hoffman; A Gomes; D E Kuhl
Journal:  Am J Cardiol       Date:  1982-04-01       Impact factor: 2.778

9.  Noninvasive assessment of coronary stenoses with myocardial perfusion imaging during pharmacologic coronary vasodilatation. V. Detection of 47 percent diameter coronary stenosis with intravenous nitrogen-13 ammonia and emission-computed tomography in intact dogs.

Authors:  K L Gould; H R Schelbert; M E Phelps; E J Hoffman
Journal:  Am J Cardiol       Date:  1979-02       Impact factor: 2.778

10.  Measurements of regional tissue and blood-pool radiotracer concentrations from serial tomographic images of the heart.

Authors:  E Henze; S C Huang; O Ratib; E Hoffman; M E Phelps; H R Schelbert
Journal:  J Nucl Med       Date:  1983-11       Impact factor: 10.057

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.