Scanning electron microscopy of chronically stimulated platinum intracochlear electrodes.

R K Shepherd, M T Murray, M E Houghton, G M Clark.   

Abstract

Platinum electrodes were examined for evidence of corrosion using a scanning electron microscope (SEM). In vivo electrodes, stimulated using charge-balanced biphasic pulses for periods of up to 2000 h at charge densities of 0.18-0.32 microC mm-2 geom. per phase, were compared with in vitro electrodes stimulated in inorganic saline using similar stimulus parameters, and with in vivo control electrodes. The in vitro stimulated electrodes showed evidence of platinum corrosion at high charge density and aggregate charge injection. Significantly, the in vivo stimulated electrodes showed no evidence of stimulus induced corrosion. Indeed, their surfaces were similar to the in vivo control electrodes. In vitro electrochemical studies have demonstrated that proteins play a significant role in the inhibition of platinum dissolution: the present study has demonstrated an inhibitory effect in vivo. This may be due to the presence of proteins.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3840392     DOI: 10.1016/0142-9612(85)90019-5

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  Evaluation of focused multipolar stimulation for cochlear implants: a preclinical safety study.

Authors:  Robert K Shepherd; Andrew K Wise; Ya Lang Enke; Paul M Carter; James B Fallon
Journal:  J Neural Eng       Date:  2017-08       Impact factor: 5.379

2.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

Review 3.  Gels, jets, mosquitoes, and magnets: a review of implantation strategies for soft neural probes.

Authors:  Nicholas V Apollo; Brendan Murphy; Kayla Prezelski; Nicolette Driscoll; Andrew G Richardson; Timothy H Lucas; Flavia Vitale
Journal:  J Neural Eng       Date:  2020-09-11       Impact factor: 5.379

4.  Techniques for processing eyes implanted with a retinal prosthesis for localized histopathological analysis.

Authors:  David A X Nayagam; Ceara McGowan; Joel Villalobos; Richard A Williams; Cesar Salinas-LaRosa; Penny McKelvie; Irene Lo; Meri Basa; Justin Tan; Chris E Williams
Journal:  J Vis Exp       Date:  2013-08-02       Impact factor: 1.355

5.  Platinum corrosion products from electrode contacts of human cochlear implants induce cell death in cell culture models.

Authors:  Kirsten Wissel; Gudrun Brandes; Nils Pütz; Gian Luigi Angrisani; Jan Thieleke; Thomas Lenarz; Martin Durisin
Journal:  PLoS One       Date:  2018-05-15       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.