Literature DB >> 3818676

An in vitro simulation study of impulsive force transmission along the lower skeletal extremity.

M L Chu, S Yazdani-Ardakani, I A Gradisar, M J Askew.   

Abstract

Several investigators have revealed that a relationship exists between articular cartilage deterioration and the mechanical stress that results from transient impulsive forces created in the lower extremity during gait. This study is an investigation of the transmission of impulse waves through the lower extremity and the effect of knee pathology and prosthetic knee replacement on their transmission. An in vitro experiment is performed using human cadaver specimens that are instrumented with accelerometers. The distal end of the tibia is impacted with a vibration shaker to simulate heel strike. The results indicate that the normal knee joint is able to attenuate 59% of the transient peak force applied to it by the tibia. This attenuation capacity is reduced by knee pathology and decreases further with implantation of a knee prosthesis. The results indicate that abnormalities at the knee may increase the risk of degenerative changes at the ankle, hip and in the spine due to increased transient impulsive forces.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3818676     DOI: 10.1016/0021-9290(86)90115-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Kinematic and kinetic parameters associated with running in different shoes.

Authors:  P J McNair; R N Marshall
Journal:  Br J Sports Med       Date:  1994-12       Impact factor: 13.800

2.  Detection of Meniscal Tear Effects on Tibial Vibration Using Passive Knee Sound Measurements.

Authors:  Goktug C Ozmen; Mohsen Safaei; Beren Semiz; Daniel C Whittingslow; Jennifer L Hunnicutt; Sampath Prahalad; Regina Hash; John W Xerogeanes; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

3.  Vibration Characterization of the Human Knee Joint in Audible Frequencies.

Authors:  Mohsen Safaei; Nicholas B Bolus; Alper Erturk; Omer T Inan
Journal:  Sensors (Basel)       Date:  2020-07-25       Impact factor: 3.576

4.  Knee Joint Menisci Are Shock Absorbers: A Biomechanical In-Vitro Study on Porcine Stifle Joints.

Authors:  Andreas M Seitz; Jonas Schwer; Luisa de Roy; Daniela Warnecke; Anita Ignatius; Lutz Dürselen
Journal:  Front Bioeng Biotechnol       Date:  2022-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.