A new enzymatic colorimetric method for the determination of creatinine in serum and urine (Creatinine PAP, Cat. No. 839434 and 836885, Boehringer Mannheim GmbH, Mannheim, FRG) was evaluated in 16 clinical chemistry laboratories and the manufacturer's testing laboratory. The test is based on the enzymatic degradation of creatinine and its reaction products by creatininase, creatinase and sarcosine oxidase. The H2O2 produced by the oxidation of sarcosine is determined using a modified Trinder reaction. The test can be carried out either manually or in mechanized analysers which enable the pipetting of a starter reagent to be made. The following results were obtained: Depending on the analyte concentration (range 40 to 1240 mumol/l), medians for the coefficients of variation were: 4.6-0.9% within-run and 6.4-2.8% between-day. At 546 nm the linear measuring range extended from 13 mumol/l (detection limit) to 1780 mumol/l, at 510 nm from 9 to 890 mumol/l. Recoveries in aqueous and human serum based standards as well as method comparisons with Fuller's earth methods and an enzymatic UV test indicate a high accuracy of this new enzymatic method in serum and urine. No interference was observed with haemolysed and lipaemic sera. This also applied to anticoagulants and to 36 drugs at therapeutic concentrations, with the exception of calcium dobesilate, which led to decreased values. Icteric samples containing 120-310 mumol/l bilirubin invariably led to decreased creatinine values (10-50 mumol/l lower). In a collaborative study substantially better interlaboratory agreement was observed with the new colorimetric enzymatic test than with the comparison methods (enzymatic UV test and various Jaffe procedures). In conclusion, this new enzymatic colorimetric test permits a precise and specific determination of creatinine in serum and urine. It makes a considerable contribution to improving the interlaboratory comparability of creatinine determinations and is suitable for routine use.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3806017

Source DB:  PubMed          Journal:  J Clin Chem Clin Biochem        ISSN: 0340-076X


  12 in total

1.  Evaluation of an enzymatic method for determining creatinine in plasma.

Authors:  H Crocker; M D Shephard; G H White
Journal:  J Clin Pathol       Date:  1988-05       Impact factor: 3.411

Review 2.  Molecular Probes, Chemosensors, and Nanosensors for Optical Detection of Biorelevant Molecules and Ions in Aqueous Media and Biofluids.

Authors:  Joana Krämer; Rui Kang; Laura M Grimm; Luisa De Cola; Pierre Picchetti; Frank Biedermann
Journal:  Chem Rev       Date:  2022-01-07       Impact factor: 60.622

3.  A meta-analysis of genome-wide data from five European isolates reveals an association of COL22A1, SYT1, and GABRR2 with serum creatinine level.

Authors:  Cristian Pattaro; Alessandro De Grandi; Veronique Vitart; Caroline Hayward; Andre Franke; Yurii S Aulchenko; Asa Johansson; Sarah H Wild; Scott A Melville; Aaron Isaacs; Ozren Polasek; David Ellinghaus; Ivana Kolcic; Ute Nöthlings; Lina Zgaga; Tatijana Zemunik; Carsten Gnewuch; Stefan Schreiber; Susan Campbell; Nick Hastie; Mladen Boban; Thomas Meitinger; Ben A Oostra; Peter Riegler; Cosetta Minelli; Alan F Wright; Harry Campbell; Cornelia M van Duijn; Ulf Gyllensten; James F Wilson; Michael Krawczak; Igor Rudan; Peter P Pramstaller
Journal:  BMC Med Genet       Date:  2010-03-11       Impact factor: 2.103

4.  Comparison between the enzymatic vitros assay for creatinine determination and three other methods adapted on the Olympus analyzer.

Authors:  S Badiou; A M Dupuy; B Descomps; J P Cristolead
Journal:  J Clin Lab Anal       Date:  2003       Impact factor: 2.352

5.  Sarcosine oxidase: structure, function, and the application to creatinine determination.

Authors:  H Suzuki
Journal:  Amino Acids       Date:  1994-02       Impact factor: 3.520

6.  Adjustment of creatinine clearance improves accuracy of Calvert's formula for carboplatin dosing.

Authors:  Y Ando; H Minami; H Saka; M Ando; S Sakai; K Shimokata
Journal:  Br J Cancer       Date:  1997       Impact factor: 7.640

7.  Strong Negative Interference by Calcium Dobesilate in Sarcosine Oxidase Assays for Serum Creatinine Involving the Trinder Reaction.

Authors:  Xiuzhi Guo; Li'an Hou; Xinqi Cheng; Tianjiao Zhang; Songlin Yu; Huiling Fang; Liangyu Xia; Zhihong Qi; Xuzhen Qin; Lin Zhang; Qian Liu; Li Liu; Shuling Chi; Yingying Hao; Ling Qiu
Journal:  Medicine (Baltimore)       Date:  2015-06       Impact factor: 1.889

8.  Negative interferences by calcium dobesilate in the detection of five serum analytes involving Trinder reaction-based assays.

Authors:  Xiuzhi Guo; Li'an Hou; Yicong Yin; Jie Wu; Fang Zhao; Liangyu Xia; Xinqi Cheng; Qian Liu; Li Liu; Ermu Xu; Ling Qiu
Journal:  PLoS One       Date:  2018-02-12       Impact factor: 3.240

9.  LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers' 24 Hour Urine.

Authors:  Hongwei Hou; Wei Xiong; Xiaotao Zhang; Dongkui Song; Gangling Tang; Qingyuan Hu
Journal:  J Anal Methods Chem       Date:  2012-11-11       Impact factor: 2.193

10.  Hospital-based screening to detect patients with cadmium nephropathy in cadmium-polluted areas in Japan.

Authors:  Toru Sasaki; Hyogo Horiguchi; Akira Arakawa; Etsuko Oguma; Atsushi Komatsuda; Kenichi Sawada; Katsuyuki Murata; Kazuhito Yokoyama; Takehisa Matsukawa; Momoko Chiba; Yuki Omori; Norihiro Kamikomaki
Journal:  Environ Health Prev Med       Date:  2019-01-26       Impact factor: 3.674

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.