Literature DB >> 3804860

Collection of airborne micro-organisms on Nuclepore filters, estimation and analysis--CAMNEA method.

U Palmgren, G Ström, G Blomquist, P Malmberg.   

Abstract

The total number of airborne micro-organisms collected on Nuclepore filters was determined by acridine orange staining and epifluorescence microscopy. The viable fraction of the total numbers varied significantly when actinomycete and fungal spores from different environments were stored on the filter surface for 1 week, although the microflora composition was not altered. A high correlation between viable and total counts was noted in environments where the airborne flora was dominated by fungal spores, while a low correlation was found for airborne bacteria. Peak values of the total counts registered in some work environments varied between 10(7) and 10(11) micro-organisms/m3. Size analysis showed a dominating fraction of respirable micro-organisms (aerodynamical diameter less than 5 micron). The investigation shows that it is of the utmost importance to combine viable counts with total count enumeration in the study of exposure to micro-organisms in work-related situations.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3804860     DOI: 10.1111/j.1365-2672.1986.tb04303.x

Source DB:  PubMed          Journal:  J Appl Bacteriol        ISSN: 0021-8847


  24 in total

1.  Exposure assessment and lung function in pig and poultry farmers.

Authors:  K Radon; C Weber; M Iversen; B Danuser; S Pedersen; D Nowak
Journal:  Occup Environ Med       Date:  2001-06       Impact factor: 4.402

2.  Comparison of bioaerosol sampling methods in barns housing swine.

Authors:  P S Thorne; M S Kiekhaefer; P Whitten; K J Donham
Journal:  Appl Environ Microbiol       Date:  1992-08       Impact factor: 4.792

3.  Relationship between bacterial counts and endotoxin concentrations in the air of wastewater treatment plants.

Authors:  S Laitinen; A Nevalainen; M Kotimaa; J Liesivuori; P J Martikainen
Journal:  Appl Environ Microbiol       Date:  1992-11       Impact factor: 4.792

4.  Assessment of the total inflammatory potential of bioaerosols by using a granulocyte assay.

Authors:  Michael Timm; Anne Mette Madsen; Jørgen Vinsløv Hansen; Lise Moesby; Erik Wind Hansen
Journal:  Appl Environ Microbiol       Date:  2009-10-16       Impact factor: 4.792

5.  Carbon dioxide (CO2) demand-controlled ventilation in university computer classrooms and possible effects on headache, fatigue and perceived indoor environment: an intervention study.

Authors:  Dan Norbäck; Klas Nordström; Zhuohui Zhao
Journal:  Int Arch Occup Environ Health       Date:  2012-03-16       Impact factor: 3.015

6.  Seasonal variations of indoor microbial exposures and their relation to temperature, relative humidity, and air exchange rate.

Authors:  Mika Frankel; Gabriel Bekö; Michael Timm; Sine Gustavsen; Erik Wind Hansen; Anne Mette Madsen
Journal:  Appl Environ Microbiol       Date:  2012-09-21       Impact factor: 4.792

7.  The mitochondrial toxin produced by Streptomyces griseus strains isolated from an indoor environment is valinomycin.

Authors:  M A Andersson; R Mikkola; R M Kroppenstedt; F A Rainey; J Peltola; J Helin; K Sivonen; M S Salkinoja-Salonen
Journal:  Appl Environ Microbiol       Date:  1998-12       Impact factor: 4.792

8.  Species-specific fungal DNA in airborne dust as surrogate for occupational mycotoxin exposure?

Authors:  Anne Straumfors Halstensen
Journal:  Int J Mol Sci       Date:  2008-12-10       Impact factor: 6.208

9.  Influence of horse stable environment on human airways.

Authors:  Lena Elfman; Miia Riihimäki; John Pringle; Robert Wålinder
Journal:  J Occup Med Toxicol       Date:  2009-05-25       Impact factor: 2.646

10.  Airborne fungal and bacterial components in PM1 dust from biofuel plants.

Authors:  Anne Mette Madsen; Vivi Schlünssen; Tina Olsen; Torben Sigsgaard; Hediye Avci
Journal:  Ann Occup Hyg       Date:  2009-07-20
View more