Literature DB >> 3801298

A laboratory model for the evaluation of thromboembolic complications of small diameter vascular prostheses.

A G Nordestgaard, J A Buckels, S E Wilson.   

Abstract

Seventeen 2 mm and twenty-five 3 mm internal diameter petrafluoroethylene (PTFE) vascular prostheses were inserted as aortic interposition grafts in 42 rabbits. The 3 month patency with 2 mm grafts was disappointingly low at 24% whereas patency with 3 mm grafts was 82%, comparable to other studies of small diameter prostheses. Hind limb paralysis occurred in 18 animals and proved a reliable indicator of graft thrombosis. Unexpected and previously unreported lower limb ulceration occurred in nine of the 23 long term survivors. Angiographic studies indicated that these ulcers were due to distal embolization of loosely attached mural thrombi. These were found in four of eight patent grafts removed from animals with leg ulcers. Aortic grafting in the rabbit is an economic model for the study of thromboembolic phenomena in small diameter vascular prostheses and their modification by pharmacological agents.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3801298      PMCID: PMC2013122     

Source DB:  PubMed          Journal:  Br J Exp Pathol        ISSN: 0007-1021


  13 in total

1.  THROMBOPLASTIC AND FIBRINOLYTIC ACTIVITIES IN VESSELS OF ANIMALS.

Authors:  T ASTRUP; K BULUK
Journal:  Circ Res       Date:  1963-09       Impact factor: 17.367

2.  A new vascular prosthesis for a small caliber artery.

Authors:  H Matsumoto; T Hasegawa; K Fuse; M Yamamoto; M Saigusa
Journal:  Surgery       Date:  1973-10       Impact factor: 3.982

3.  Small vessel replacement with gore-tex (expanded polytetrafluoroethylene).

Authors:  A Florian; L H Cohn; G J Dammin; J J Collins
Journal:  Arch Surg       Date:  1976-03

4.  A small arterial substitute: expanded microporous polytetrafluoroethylene: patency versus porosity.

Authors:  C D Campbell; D Goldfarb; R Roe
Journal:  Ann Surg       Date:  1975-08       Impact factor: 12.969

5.  Gore-Tex (polytetrafluoroethylene) in canine coronary artery bypass.

Authors:  J B Hancock; P L Forshaw; M P Kaye
Journal:  J Thorac Cardiovasc Surg       Date:  1980-07       Impact factor: 5.209

6.  Microvascular synthetic grafts.

Authors:  H H Caffee
Journal:  Plast Reconstr Surg       Date:  1980-09       Impact factor: 4.730

7.  Evaluation of a microvascular prosthesis of microporous polytetrafluoroethylene in rats.

Authors:  J Fonegra; E Chignier; G Clendinnen; R Eloy
Journal:  Surg Gynecol Obstet       Date:  1982-05

8.  Heparin and small caliber polytetrafluoroethylene grafts in the carotid arteries of rats.

Authors:  K J Barry; R M Scott; E M Keough
Journal:  J Microsurg       Date:  1981

9.  Minute vascular replacements.

Authors:  B A Christie; V Ketharanathan; L J Perloff
Journal:  Arch Surg       Date:  1982-10

10.  Platelet--arterial synthetic graft interaction and its modification.

Authors:  A D Callow; R Connolly; T F O'Donnell; R Gembarowicz; E Keough; K Ramberg-Laskaris; C R Valeri
Journal:  Arch Surg       Date:  1982-11
View more
  1 in total

1.  Non-equilibrium organosilane plasma polymerization for modulating the surface of PTFE towards potential blood contact applications.

Authors:  Vineeth M Vijayan; Bernabe S Tucker; Patrick T J Hwang; Pratheek S Bobba; Ho-Wook Jun; Shane A Catledge; Yogesh K Vohra; Vinoy Thomas
Journal:  J Mater Chem B       Date:  2020-04-08       Impact factor: 6.331

  1 in total