Abstract

Cochlear damage from electrode insertion, a potential cause of further neural degeneration, is a major concern in the use of intracochlear electrodes. A study was undertaken to evaluate mechanisms by which damage may occur. Fresh human temporal bone preparations were created to allow direct intracochlear observation during round window insertion of a free-fitting multichannel intracochlear electrode array. The path taken by the electrode, point of first resistance, and any resulting damage were documented. Tips of study electrodes in this preparation tended to embed in the outer wall of the scala tympani. The integrity of the basilar partition was largely maintained during insertion when this was stopped at the point of first resistance. However, insertion beyond the point of first resistance typically resulted in widespread damage to intracochlear structures.

Entities:  

Mesh:

Year:  1987        PMID: 3796175     DOI: 10.1288/00005537-198701000-00011

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  15 in total

1.  Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants.

Authors:  Bryan E Pfingst; Li Xu
Journal:  J Assoc Res Otolaryngol       Date:  2003-11-20

2.  Factors associated with incomplete insertion of electrodes in cochlear implant surgery: a histopathologic study.

Authors:  Joonhan Lee; Joseph B Nadol; Donald K Eddington
Journal:  Audiol Neurootol       Date:  2010-06-19       Impact factor: 1.854

3.  Representations of Time-Varying Cochlear Implant Stimulation in Auditory Cortex of Awake Marmosets (Callithrix jacchus).

Authors:  Luke A Johnson; Charles C Della Santina; Xiaoqin Wang
Journal:  J Neurosci       Date:  2017-06-20       Impact factor: 6.167

Review 4.  The development of the Nucleus Freedom Cochlear implant system.

Authors:  James F Patrick; Peter A Busby; Peter J Gibson
Journal:  Trends Amplif       Date:  2006-12

5.  CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays.

Authors:  Thi Hau Vu; Chiara Perazzini; Mathilde Puechmaille; Aurélie Bachy; Aurélien Mulliez; Louis Boyer; Thierry Mom; Jean Gabrillargues
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-04-22       Impact factor: 2.503

6.  Selective Neuronal Activation by Cochlear Implant Stimulation in Auditory Cortex of Awake Primate.

Authors:  Luke A Johnson; Charles C Della Santina; Xiaoqin Wang
Journal:  J Neurosci       Date:  2016-12-07       Impact factor: 6.167

7.  Miniature pigs: a large animal model of cochlear implantation.

Authors:  Haijin Yi; Weiwei Guo; Wei Chen; Lei Chen; Jingying Ye; Shiming Yang
Journal:  Am J Transl Res       Date:  2016-12-15       Impact factor: 4.060

8.  Comparative study of two different perimodiolar and a straight cochlear implant electrode array: surgical and audiological outcomes.

Authors:  Octavio Garaycochea; Raquel Manrique-Huarte; Carlos Lazaro; Alicia Huarte; Carlos Prieto; Marta Alvarez de Linera-Alperi; Manuel Manrique
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-10-21       Impact factor: 2.503

Review 9.  Cochlear Implants and Children with Vestibular Impairments.

Authors:  Sharon L Cushing; Blake C Papsin
Journal:  Semin Hear       Date:  2018-07-20

10.  Role of electrode placement as a contributor to variability in cochlear implant outcomes.

Authors:  Charles C Finley; Timothy A Holden; Laura K Holden; Bruce R Whiting; Richard A Chole; Gail J Neely; Timothy E Hullar; Margaret W Skinner
Journal:  Otol Neurotol       Date:  2008-10       Impact factor: 2.311

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.