Literature DB >> 3795108

Rapid resetting of rabbit aortic baroreceptors and reflex heart rate responses by directional changes in blood pressure.

S L Burke, P K Dorward, P I Korner.   

Abstract

In both anaesthetized and conscious rabbits, perivascular balloon inflations slowly raised or lowered mean arterial pressure (M.A.P.), at 1-2 mmHg/s, from resting to various plateau pressures. Deflations then returned the M.A.P. to resting. 'Steady-state' curves relating M.A.P. to unitary aortic baroreceptor firing, integrated aortic nerve activity and heart rate were derived during the primary and return pressure changes and they formed typical hysteresis loops. In single units, return M.A.P.-frequency curves were shifted in the same direction as the primary pressure changes by an average 0.37 mmHg per mmHg change in M.A.P. Shifts were linearly related to the changes in M.A.P. between resting and plateau levels for all pressure rises and for falls less than 30 mmHg. They were established within 30 s and were quantitatively similar to the rapid resetting of baroreceptor function curves found 15 min-2 h after a change in resting M.A.P. (Dorward, Andresen, Burke, Oliver & Korner, 1982). Unit threshold pressures were shifted within 20 s to the same extent as the over-all curve shift to which they contributed. In the whole aortic nerve, return M.A.P.-integrated activity curves were shifted to same degree as unit function curves in both anaesthetized and conscious rabbits. Simultaneous shifts of return reflex M.A.P.-heart rate curves were also seen in conscious rabbits within 30 s. During M.A.P. falls, receptor and reflex hysteresis was similar, but during M.A.P. rises, reflex shifts were double baroreceptor shifts, suggesting the involvement of other pressure-sensitive receptors. We conclude that hysteresis shifts in baroreceptor function curves, which follow the reversal of slow ramp changes in blood pressure are a form of rapid resetting. They are accompanied by rapid resetting of reflex heart rate responses. We regard this as an important mechanism in blood pressure control which produces relatively high-gain reflex responses, during slow directional pressure changes, over a wider range of absolute pressure levels than would otherwise be possible.

Entities:  

Mesh:

Year:  1986        PMID: 3795108      PMCID: PMC1182871          DOI: 10.1113/jphysiol.1986.sp016226

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  19 in total

1.  Mechanism of the carotid sinus in experimental hypertension.

Authors:  P KEZDI
Journal:  Circ Res       Date:  1962-07       Impact factor: 17.367

2.  Characteristics of single carotid sinus baroreceptor fibers and whole nerve activity in the normotensive and the renal hypertensive dog.

Authors:  P Sleight; J L Robinson; D E Brooks; P M Rees
Journal:  Circ Res       Date:  1977-12       Impact factor: 17.367

Review 3.  Role of cardiac vagal C-fibers in cardiovascular control.

Authors:  P Thorén
Journal:  Rev Physiol Biochem Pharmacol       Date:  1979       Impact factor: 5.545

Review 4.  Vagal sensory receptors and their reflex effects.

Authors:  A S Paintal
Journal:  Physiol Rev       Date:  1973-01       Impact factor: 37.312

5.  Characteristics of single aortic and right subclavian baroreceptor fiber activity in rabbits with chronic renal hypertension.

Authors:  J E Angell-James
Journal:  Circ Res       Date:  1973-02       Impact factor: 17.367

6.  Aortic baroreceptor activity in normal and hypertensive rabbits.

Authors:  H Aars
Journal:  Acta Physiol Scand       Date:  1968-03

7.  Time course of baroreceptor resetting in short-term hypotension in the rat.

Authors:  H C Salgado; E M Krieger
Journal:  Am J Physiol       Date:  1978-05

8.  Individual and combined actions of calcium, sodium, and potassium ions on baroreceptors in the rat.

Authors:  M C Andresen; S Kuraoka; A M Brown
Journal:  Circ Res       Date:  1979-12       Impact factor: 17.367

9.  A comparison of aortic baroreceptor discharge in normotensive and spontaneously hypertensive rats.

Authors:  A M Brown; W R Saum; F H Tuley
Journal:  Circ Res       Date:  1976-10       Impact factor: 17.367

10.  Operational sensitivity and acute resetting of aortic baroreceptors in dogs.

Authors:  H M Coleridge; J C Coleridge; M P Kaufman; A Dangel
Journal:  Circ Res       Date:  1981-05       Impact factor: 17.367

View more
  3 in total

1.  Mechanical and neural contributions to hysteresis in the cardiac vagal limb of the arterial baroreflex.

Authors:  Péter Studinger; Richard Goldstein; J Andrew Taylor
Journal:  J Physiol       Date:  2007-07-19       Impact factor: 5.182

2.  Acute adaptation and resetting of the baroreflex control of vascular resistance in the canine hindquarters and mesentery.

Authors:  H I Chen; K C Chang; H C Liu; C H Lin
Journal:  Pflugers Arch       Date:  1993-08       Impact factor: 3.657

3.  High-pass filter characteristics of the baroreflex--a comparison of frequency domain and pharmacological methods.

Authors:  Istvan Bonyhay; Marcelo Risk; Roy Freeman
Journal:  PLoS One       Date:  2013-11-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.