Literature DB >> 3794113

Measurement of left ventricular stroke volume using continuous wave Doppler echocardiography of the ascending aorta and M-mode echocardiography of the aortic valve.

A Bouchard, S Blumlein, N B Schiller, S Schlitt, B F Byrd, T Ports, K Chatterjee.   

Abstract

A number of reports have described different Doppler echocardiographic methods to calculate left ventricular stroke volume and cardiac output, but the clinical application of the noninvasive measurements of cardiac function remains in the early stages of development. This slow dissemination may be partly explained by the varying success of these ultrasound methods in determining accurate left ventricular stroke volume. The purpose of this study was to improve the simplicity and accuracy of Doppler stroke volume determination so that it could be more easily applied to patient management. Stroke volume was measured using the product of the integral of aortic velocity obtained by continuous wave Doppler technique and the M-mode tracing of the aortic valve, validating the data against cardiac output obtained by thermodilution technique in 41 patients (r = 0.95, SEE = 7 cc). Intra- and interobserver variability was between 9 and 11%. The results of different sampling sites and the temporal relation between Doppler and thermodilution measurements were also studied. Analysis of 21 patients who had M-mode and two-dimensional echocardiographic studies of the aortic root revealed that the method using M-mode measurement of aortic valve area was most accurate in determining left ventricular stroke volume (r = 0.94, SEE = 10 cc), stroke volume being overestimated when area measurements of the ascending aorta were used. In conclusion, maximal ascending aortic velocity determined by continuous wave Doppler echocardiography with M-mode measurement of aortic valve area can be used to calculate left ventricular stroke volume and cardiac output. The simplicity and practicality of this method should enhance the clinical application of Doppler echocardiography as a noninvasive monitoring technique.

Entities:  

Mesh:

Year:  1987        PMID: 3794113     DOI: 10.1016/s0735-1097(87)80085-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  Validation of a skills assessment scoring system for transesophageal echocardiographic monitoring of hemodynamics.

Authors:  Cyril Charron; Gwenaël Prat; Vincent Caille; Guillaume Belliard; Montaine Lefèvre; Philippe Aegerter; Jean-Michel Boles; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2007-08-16       Impact factor: 17.440

2.  Biological aortic age derived from the arterial pressure waveform.

Authors:  Shigeki Shibata; Benjamin D Levine
Journal:  J Appl Physiol (1985)       Date:  2011-02-03

3.  Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.

Authors:  D B Northridge; I N Findlay; J Wilson; E Henderson; H J Dargie
Journal:  Br Heart J       Date:  1990-02

4.  Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

Authors:  T Stan Gregory; John Oshinski; Ehud J Schmidt; Raymond Y Kwong; William G Stevenson; Zion Tsz Ho Tse
Journal:  Circ Cardiovasc Imaging       Date:  2015-12       Impact factor: 7.792

5.  High Flow-Mediated Vasodilatation Predicts Pulmonary Edema in Liver Transplant Patients.

Authors:  Shyh-Ming Chen; Chao-Long Chen; Han-Tan Chai; Chee-Chien Yong; Hsien-Wen Hsu; Yu-Fan Cheng; Morgan Fu; Yu-Tung Anton Huang; Chi-Ling Hang
Journal:  Acta Cardiol Sin       Date:  2013-05       Impact factor: 2.672

6.  Echocardiographic assessment of cardiac function in shocked very low birthweight infants.

Authors:  A B Gill; A M Weindling
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

7.  Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support.

Authors:  W R Morrow; D J Murphy; D J Fisher; J C Huhta; L S Jefferson; E O Smith
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.