Influence of knowledge of peak flow on self assessment of asthma: studies with a coded peak flow meter.

C M Higgs, R B Richardson, D A Lea, G T Lewis, G Laszlo.   

Abstract

A portable peak flow meter based on a turbine transducer that can display results in code has been developed. Its performance compares well with the Wright peak flow meter. Records of subjective self assessment of asthma on a visual analogue scale and of peak flow (PEF) were compared in 12 subjects with asthma. PEF measurements were made with a coded meter for two weeks and an uncoded meter for two weeks in random order. The correlation between visual analogue scale score and PEF was invariably stronger when PEF was known. Changes in perception of asthma were measured by comparing the slopes and relative positions of the regressions of visual analogue on PEF. When PEF was uncoded awareness of asthma was significantly increased in five patients, predominantly those whose perception was poorest while they were using the coded meter, and decreased in only one patient. In two patients the results were unsuitable for this type of analysis. Knowledge of PEF therefore may influence subjective self assessment in patients with bronchial asthma. For objective studies of symptoms of asthma, PEF readings should be unknown to the patient. Perception of asthma may, however, be improved in patients with poor ability to detect changes in bronchial calibre by uncoded measurement of peak flow at home.

Entities:  

Mesh:

Year:  1986        PMID: 3787553      PMCID: PMC460428          DOI: 10.1136/thx.41.9.671

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  7 in total

1.  Some observations on peak expiratory flow.

Authors:  R J SHEPHARD
Journal:  Thorax       Date:  1962-03       Impact factor: 9.139

2.  Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.

Authors:  H G Oldham; M M Bevan; M McDermott
Journal:  Thorax       Date:  1979-12       Impact factor: 9.139

3.  Relationship between bronchial reactivity, airway caliber, and severity of asthma.

Authors:  A R Rubinfeld; M C Pain
Journal:  Am Rev Respir Dis       Date:  1977-03

4.  Pocket-sized device for measuring forced expiratory volume in one second and forced vital capacity.

Authors:  P J Chowienczyk; C P Lawson
Journal:  Br Med J (Clin Res Ed)       Date:  1982-07-03

5.  Calibration of some Wright peak flow meters.

Authors:  J Fisher; A Shaw
Journal:  Br J Anaesth       Date:  1980-04       Impact factor: 9.166

6.  Asthma mortality in Birmingham 1975-7: 53 deaths.

Authors:  L P Ormerod; D E Stableforth
Journal:  Br Med J       Date:  1980-03-08

7.  An electronic peak flow meter with optional coded display.

Authors:  R B Richardson; C M Higgs; D A Lea; G T Lewis; G Laszlo
Journal:  Clin Phys Physiol Meas       Date:  1984-08
  7 in total
  5 in total

1.  British Thoracic Society summer meeting. 11-13 July 1990, Birmingham. Abstracts.

Authors: 
Journal:  Thorax       Date:  1990-10       Impact factor: 9.139

2.  Alternative and complementary medicine for asthma.

Authors:  D J Lane; T V Lane
Journal:  Thorax       Date:  1991-11       Impact factor: 9.139

3.  Current perspectives on symptom perception in asthma: a biomedical and psychological review.

Authors:  S Rietveld; J F Brosschot
Journal:  Int J Behav Med       Date:  1999

4.  Accuracy of perception of severity of asthma: patients treated in general practice.

Authors:  A H Kendrick; C M Higgs; M J Whitfield; G Laszlo
Journal:  BMJ       Date:  1993-08-14

5.  Chronic asthma and hypnotherapy.

Authors:  C M Higgs
Journal:  J R Soc Med       Date:  1989-07       Impact factor: 18.000