Literature DB >> 3783194

Pulse oximetry during cardiac catheterization in children with congenital heart disease.

A M Lynn, A Bosenberg.   

Abstract

One hundred and five children with congenital heart disease were monitored by pulse oximetry during cardiac catheterization. Excellent correlation (r = 0.95) was found between oxygen saturation values obtained with pulse oximetry and those obtained from arterial blood in 133 data pairs. This correlation was described by the regression equation y = 0.91x + 8.1. The correlation was also excellent in 47 data pairs with saturation values of less than 90% (r = 0.94, y = 0.93x + 6.0) from 36 cyanotic children. The clinical usefulness of pulse oximetry in the early recognition of decreased pulmonary blood flow or partial airway obstruction was demonstrated. Early diagnosis of changes in oxygenation was especially helpful in children with cyanotic congenital heart disease, in whom small changes in arterial oxygen tension may cause large changes in oxygen saturation.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3783194     DOI: 10.1007/bf02851170

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  6 in total

1.  Noninvasive detection of profound arterial desaturations using a pulse oximetry device.

Authors:  F G Mihm; B D Halperin
Journal:  Anesthesiology       Date:  1985-01       Impact factor: 7.892

2.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

3.  Infrared heat lamps interfere with pulse oximeters.

Authors:  T D Brooks; D A Paulus; W E Winkle
Journal:  Anesthesiology       Date:  1984-11       Impact factor: 7.892

4.  Physiological and clinical significance of PtcO2 and PtcCO2 measurements.

Authors:  W C Shoemaker; D Vidyasagar
Journal:  Crit Care Med       Date:  1981-10       Impact factor: 7.598

5.  Comparison of a pulse oximeter with an ear oximeter and an in-vitro oximeter.

Authors:  N Mackenzie
Journal:  J Clin Monit       Date:  1985-07

6.  Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension.

Authors:  S Fanconi; P Doherty; J F Edmonds; G A Barker; D J Bohn
Journal:  J Pediatr       Date:  1985-09       Impact factor: 4.406

  6 in total
  2 in total

Review 1.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 2.  Pulse oximetry: a review with emphasis on applications in dentistry.

Authors:  W W Schratz
Journal:  Anesth Prog       Date:  1987 May-Jun
  2 in total