Doppler echocardiographic measurement of aortic valve area in aortic stenosis: a noninvasive application of the Gorlin formula.

P Teirstein, M Yeager, P G Yock, R L Popp.   

Abstract

Thirty adult patients with aortic stenosis had Doppler echocardiography within 1 day of cardiac catheterization. Noninvasive measurement of the mean transaortic pressure gradient was calculated by applying the simplified Bernoulli equation to the continuous wave Doppler transaortic velocity recording. Stroke volume was measured noninvasively by multiplying the systolic velocity integral of flow in the left ventricular outflow tract (obtained by pulsed Doppler ultrasonography) by the cross-sectional area of the left ventricular outflow tract (measured by two-dimensional echocardiography). Non-invasive measurement of aortic valve area was calculated by two methods. In method 1, the Gorlin equation was applied using Doppler-derived mean pressure gradient, cardiac output and systolic ejection period. Method 2 used the continuity equation. These noninvasive measurements were compared with invasive measurements using linear regression analysis, and mean pressure gradients correlated well (r = 0.92). Aortic valve area by either noninvasive method also correlated well with cardiac catheterization values (method 1, r = 0.87; method 2, r = 0.88). The sensitivity of Doppler detection of critical aortic stenosis was 0.86, with a specificity of 0.88 and a positive predictive value of 0.86. Cardiac output measured nonsimultaneously showed poor correlation (r = 0.51). Doppler echocardiography can distinguish critical from noncritical aortic stenosis with a high degree of accuracy. Measurement of aortic valve area aids interpretation of Doppler-derived mean pressure gradient data when the gradients are in an intermediate range (30 to 50 mm Hg).

Entities:  

Mesh:

Year:  1986        PMID: 3760380     DOI: 10.1016/s0735-1097(86)80382-5

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  12 in total

1.  Activated factor XI and tissue factor in aortic stenosis: links with thrombin generation.

Authors:  Joanna Luszczak; Anetta Undas; Matthew Gissel; Maria Olszowska; Saulius Butenas
Journal:  Blood Coagul Fibrinolysis       Date:  2011-09       Impact factor: 1.276

2.  Continuity equation and Gorlin formula compared with directly observed orifice area in native and prosthetic aortic valves.

Authors:  J B Chambers; D C Sprigings; T Cochrane; J Allen; R Morris; M M Black; G Jackson
Journal:  Br Heart J       Date:  1992-02

3.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

4.  Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis.

Authors:  Y Bernard; N Meneveau; A Vuillemenot; D Magnin; T Anguenot; F Schiele; J P Bassand
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

5.  Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.

Authors:  J L Fischer; T Haberer; D Dickson; L Henselmann
Journal:  Br Heart J       Date:  1995-03

6.  Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT.

Authors:  Sanjay Doddamani; Michael J Grushko; Amgad N Makaryus; Vineet R Jain; Ricardo Bello; Mark A Friedman; Robert J Ostfeld; Divya Malhotra; Lawrence M Boxt; Linda Haramati; Daniel M Spevack
Journal:  Int J Cardiovasc Imaging       Date:  2008-09-04       Impact factor: 2.357

7.  Accuracy of aortic stenosis severity assessment by Doppler echocardiography: importance of image quality.

Authors:  J Bartunek; D De Bacquer; A C Rodrigues; B De Bruyne
Journal:  Int J Card Imaging       Date:  1995-06

8.  Does diabetes accelerate the progression of aortic stenosis through enhanced inflammatory response within aortic valves?

Authors:  Joanna Natorska; Ewa Wypasek; Grzegorz Grudzień; Dorota Sobczyk; Grzegorz Marek; Grzegorz Filip; Jerzy Sadowski; Anetta Undas
Journal:  Inflammation       Date:  2012-06       Impact factor: 4.092

9.  Association of the C-Reactive Protein Gene (CRP) rs1205 C>T Polymorphism with Aortic Valve Calcification in Patients with Aortic Stenosis.

Authors:  Ewa Wypasek; Daniel P Potaczek; Anetta Undas
Journal:  Int J Mol Sci       Date:  2015-10-09       Impact factor: 5.923

10.  Mast cells in human stenotic aortic valves are associated with the severity of stenosis.

Authors:  E Wypasek; J Natorska; G Grudzień; G Filip; J Sadowski; A Undas
Journal:  Inflammation       Date:  2013-04       Impact factor: 4.092