Literature DB >> 3757528

Continuous Fick cardiac output compared to thermodilution cardiac output.

G G Davies, P J Jebson, B M Glasgow, D R Hess.   

Abstract

A system has been developed to monitor continuously the components of the oxygen Fick equation: oxygen consumption by a gas exchange analyzer and arteriovenous oxygen difference by pulse and fiberoptic oximetry. A computer-based system was developed which calculates cardiac output and other variables every 20 sec. Continuous Fick (CF) cardiac output was compared to thermodilution (TD) cardiac output in 21 ventilated post-cardiac surgery patients. A total of 237 simultaneous cardiac output measurements had a range between 2 and 11 L/min. The correlation between CF and TD cardiac outputs was r = .86, with an equation of TD cardiac output = 0.92 CF cardiac output + 1.16. There was a significant (p less than .001) difference between the two methods of cardiac output estimation. The CF method was consistently lower than TD; this difference was greater at lower flows. CF cardiac output measurement is practical; it offers distinct advantages in viewing cardiac output together with oxygen demand and oxygen extraction.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3757528     DOI: 10.1097/00003246-198610000-00010

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  8 in total

1.  Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography.

Authors:  Philip J Peyton
Journal:  J Clin Monit Comput       Date:  2012-02-18       Impact factor: 2.502

2.  Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation.

Authors:  J Lynch; H Kaemmerer
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

3.  Frequently repeated Fick cardiac output measurements during anesthesia.

Authors:  M Doi; K Morita; K Ikeda
Journal:  J Clin Monit       Date:  1990-04

4.  Analysis of the accuracy of continuous thermodilution cardiac output measurement. Comparison with intermittent thermodilution and Fick cardiac output measurement.

Authors:  L Jacquet; G Hanique; D Glorieux; P Matte; M Goenen
Journal:  Intensive Care Med       Date:  1996-10       Impact factor: 17.440

5.  Abstracts of scientific papers: Seventh Medical Monitoring Technology Conference. March 9-12, 1987, Vail, Colorado.

Authors: 
Journal:  J Clin Monit       Date:  1987-10

6.  Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine.

Authors:  G G Davies; J Mendenhall; T Symreng
Journal:  J Clin Monit       Date:  1988-04

7.  Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods.

Authors:  C K Mahutte; M B Jaffe
Journal:  J Clin Monit       Date:  1995-03

Review 8.  Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.

Authors:  C F Wippermann; R G Huth; F X Schmidt; J Thul; M Betancor; D Schranz
Journal:  Intensive Care Med       Date:  1996-05       Impact factor: 17.440

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.