Literature DB >> 373475

Comparison of Marlex mesh and microporous teflon sheets when used for hernia repair in the experimental animal.

M P Elliott, G L Juler.   

Abstract

A new prosthetic material, microporous expanded Teflon (PTFE) was compared with Marlex mesh in the experimental animal. Triangular pieces of each material were placed beneath the transversalis fascia in the right and left groins of seven white New Zealand rabbits (mean weight, 8 kg). The animals were sacrificed are two week intervals. PTFE was found to retain its position and shape without local or peritoneal reaction. By contrast, Marlex mesh showed marked inflammatory reaction and scarring with complete distortion of the graft. Microscopically, PTFE was completely invaded by fibroblast at eight weeks, with flat orientation of graft to the fibrous tissue forming a "neofascia". In contrast, Marlex mesh lacked fibroblastic incorporation of the graft with marked scarring and distortion. These findings suggest that PTFE could be a useful fascial buttress in inguinal hernia repair where Marlex mesh is now used.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 373475     DOI: 10.1016/0002-9610(79)90063-1

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  13 in total

1.  Does contraction of mesh following tension free hernioplasty effect testicular or femoral vessel blood flow?

Authors:  S G Taylor; A Hair; G M Baxter; P J O'Dwyer
Journal:  Hernia       Date:  2001-03       Impact factor: 4.739

2.  Endoscopic patch repair of inguinal hernia in a female patient.

Authors:  L W Popp
Journal:  Surg Endosc       Date:  1990       Impact factor: 4.584

Review 3.  The use of mesh in gynecologic surgery.

Authors:  C B Iglesia; D E Fenner; L Brubaker
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1997

Review 4.  Surgical perspectives regarding application of biomaterials for the management of large congenital diaphragmatic hernia defects.

Authors:  Amulya K Saxena
Journal:  Pediatr Surg Int       Date:  2018-04-02       Impact factor: 1.827

5.  Evaluation of implant/host tissue interactions following intraperitoneal implantation of porcine dermal collagen prosthesis in the rat.

Authors:  Ronald N Kaleya
Journal:  Hernia       Date:  2005-10-22       Impact factor: 4.739

6.  Gamma-interferon inhibits collagen synthesis in vivo in the mouse.

Authors:  R D Granstein; G F Murphy; R J Margolis; M H Byrne; E P Amento
Journal:  J Clin Invest       Date:  1987-04       Impact factor: 14.808

7.  Comparison of PTFE, pericardium bovine and fascia lata for repair of incisional hernia in rat model, experimental study.

Authors:  S Kapan; M Kapan; E Goksoy; I Karabicak; H Oktar
Journal:  Hernia       Date:  2002-12-11       Impact factor: 4.739

Review 8.  Safety considerations for synthetic sling surgery.

Authors:  Jerry G Blaivas; Rajveer S Purohit; Matthew S Benedon; Gabriel Mekel; Michael Stern; Mubashir Billah; Kola Olugbade; Robert Bendavid; Vladimir Iakovlev
Journal:  Nat Rev Urol       Date:  2015-08-18       Impact factor: 14.432

9.  Repair of large abdominal wall defects with expanded polytetrafluoroethylene (PTFE).

Authors:  J J Bauer; B A Salky; I M Gelernt; I Kreel
Journal:  Ann Surg       Date:  1987-12       Impact factor: 12.969

10.  Comparison of prosthetic materials for abdominal wall reconstruction in the presence of contamination and infection.

Authors:  G L Brown; J D Richardson; M A Malangoni; G R Tobin; D Ackerman; H C Polk
Journal:  Ann Surg       Date:  1985-06       Impact factor: 12.969

View more