Literature DB >> 3729623

Mechanical stresses on closed cusps of porcine bioprosthetic valves: correlation with sites of calcification.

H N Sabbah, M S Hamid, P D Stein.   

Abstract

The purpose of this study was to (1) evaluate the magnitude and distribution of mechanical stresses on closed leaflets of porcine bioprosthetic valves (PBVs) by using a nonlinear, finite-element model, and (2) determine if a relationship exists between the magnitude of stresses at various sites on the leaflet and the incidence of calcification at those sites. Mechanical stresses were found to be highest near the commissures and lowest at the base of the leaflet. At a pressure of 100 mm Hg applied to the closed valve, the maximal principal normal stress was 160 kPa near the commissures, 140 kPa in the body of the leaflet, 70 kPa at the free margin, and 60 kPa near the base. Similarly, the maximal shear stress, at an applied pressure of 100 mm Hg, was 80 kPa near the commissures, 70 kPa in the body of the leaflet, 50 kPa at the free margin, and 40 kPa near the base. This distribution of mechanical stresses on the PBV leaflet coincided with the incidence of calcification of the various regions of the leaflet. Calcification was found most frequently near the commissures, less frequently in the body of the leaflet and free margin, and least frequently at the base. These observations suggest a possible causative relation between the magnitude of mechanical stresses and the site of calcification of PBV leaflets.

Entities:  

Mesh:

Year:  1986        PMID: 3729623     DOI: 10.1016/s0003-4975(10)61845-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

Review 1.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

Review 2.  Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications.

Authors:  Manuela Lopera Higuita; Leigh G Griffiths
Journal:  Tissue Eng Part B Rev       Date:  2019-11-27       Impact factor: 6.389

3.  Stentless bioprostheses have ideal haemodynamics, even in the small aortic root.

Authors:  L H Baur; Y Houdas; K H Peels; J Braun; B van Straten; A Prat; A P Kappetein; M Wolters-Geldoff; E E van der Wall; A V Bruschke; H A Huysmans
Journal:  Int J Card Imaging       Date:  2000-10

4.  Imaging analysis of collagen fiber networks in cusps of porcine aortic valves: effect of their local distribution and alignment on valve functionality.

Authors:  Mor Mega; Gil Marom; Rotem Halevi; Ashraf Hamdan; Danny Bluestein; Rami Haj-Ali
Journal:  Comput Methods Biomech Biomed Engin       Date:  2015-09-25       Impact factor: 1.763

5.  The effect of decellularisation on the real time mechanical fatigue of porcine aortic heart valve roots.

Authors:  Amisha Desai; Eileen Ingham; Helen E Berry; John Fisher; Louise M Jennings
Journal:  PLoS One       Date:  2022-04-01       Impact factor: 3.240

Review 6.  Mechanotransduction in the Cardiovascular System: From Developmental Origins to Homeostasis and Pathology.

Authors:  Gloria Garoffolo; Maurizio Pesce
Journal:  Cells       Date:  2019-12-11       Impact factor: 6.600

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.