An analysis of noise propagation in computed T2, pseudodensity, and synthetic spin-echo images.

J R MacFall, S J Riederer, H Z Wang.   

Abstract

Methods are reviewed for estimating the transverse relaxation time T2 and the pseudodensity (PD) from spin-echo measurements acquired at an arbitrary set of echo times [TEi]. Least-squares fitting is applied to the logarithmically processed signals for the case in which the weights are proportional to the inverse of the logarithmically transformed signal variances (the minimum variance case). General formulas are derived for the estimated noise levels in the PD and T2 estimates due to the propagation of uncertainties in the original measurements. It is shown that the T2 and PD estimates are anticorrelated. Additionally, an expression is derived for the variance in a synthetic spin-echo signal subsequently formed from the PD and T2 estimates. It is shown that under many circumstances a signal synthesized at some echo time can have a signal-to-noise ratio superior to that in a signal directly acquired at that time. Experimental measurements made on phantoms match the theoretical predictions to a high degree.

Entities:  

Mesh:

Year:  1986        PMID: 3724687     DOI: 10.1118/1.595956

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

Review 1.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

2.  Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory.

Authors:  Hsin-Jung Yang; Behzad Sharif; Jianing Pang; Avinash Kali; Xiaoming Bi; Ivan Cokic; Debiao Li; Rohan Dharmakumar
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

3.  Noise removal from multiple MRI images.

Authors:  S J Garnier; G L Bilbro; W E Snyder; J W Gault
Journal:  J Digit Imaging       Date:  1994-11       Impact factor: 4.056

4.  Neural network synthesis of spin echo multiecho sequences.

Authors:  S Cagnoni; D Caramella; R De Dominicis; G Valli
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

5.  Calculating T2 in images from a phased array receiver.

Authors:  Peter A Hardy; Anders H Andersen
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

6.  Radiofrequency (RF) coil impacts the value and reproducibility of cartilage spin-spin (T2) relaxation time measurements.

Authors:  B J Dardzinski; E Schneider
Journal:  Osteoarthritis Cartilage       Date:  2013-01-31       Impact factor: 6.576

7.  Bias of cartilage T2 values related to method of calculation.

Authors:  Matthew F Koff; Kimberly K Amrami; Joel P Felmlee; Kenton R Kaufman
Journal:  Magn Reson Imaging       Date:  2008-05-07       Impact factor: 2.546

8.  T2 quantification for improved detection of myocardial edema.

Authors:  Shivraman Giri; Yiu-Cho Chung; Ali Merchant; Georgeta Mihai; Sanjay Rajagopalan; Subha V Raman; Orlando P Simonetti
Journal:  J Cardiovasc Magn Reson       Date:  2009-12-30       Impact factor: 5.364

9.  T2 relaxation time of cartilage at MR imaging: comparison with severity of knee osteoarthritis.

Authors:  Timothy C Dunn; Ying Lu; Hua Jin; Michael D Ries; Sharmila Majumdar
Journal:  Radiology       Date:  2004-06-23       Impact factor: 11.105

10.  Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications.

Authors:  Florian von Knobelsdorff-Brenkenhoff; Marcel Prothmann; Matthias A Dieringer; Ralf Wassmuth; Andreas Greiser; Carsten Schwenke; Thoralf Niendorf; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2013-06-18       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.