Literature DB >> 3724419

Errors in the measurements of T2 using multiple-echo MRI techniques. I. Effects of radiofrequency pulse imperfections.

S Majumdar, S C Orphanoudakis, A Gmitro, M O'Donnell, J C Gore.   

Abstract

In principle, multiple-echo magnetic resonance imaging (MRI) can be used to estimate the spin-spin relaxation time, T2, which can then be used for quantitative tissue characterization. Although multiple echoes can be used to enhance the signal-to-noise ratio in an image, by echo addition, rf pulse imperfections modify the echo amplitudes resulting in significant errors in the estimate of T2. Imperfect 180 degree pulses do not completely invert the transverse magnetization so that the magnitude of the transverse component is reduced and a longitudinal component is generated. Successive application of such imperfect pulses generates many components that interact in a complex manner. The amplitudes of successive echoes are affected whenever the transverse components refocus, whereas the longitudinal components may be rotated into the transverse plane by subsequent pulses and may often add to the image signal or give rise to an image artifact. These effects have been analyzed theoretically and have been demonstrated for a wide range of rf pulse imperfections using both simple and composite pulses, through computer simulations based on the numerical solution of the Bloch equations. The theoretical and simulation results have been substantiated through experiments performed on a mineral oil phantom using a resistive prototype MR scanner operating at 6.35 MHz. In this paper we report the effects of improper pulse amplitude or duration for nonselective rf pulses on resonance. We separately describe the other types of imperfections caused by off-resonance effects and the use of selective pulses.

Entities:  

Mesh:

Year:  1986        PMID: 3724419     DOI: 10.1002/mrm.1910030305

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  36 in total

Review 1.  Magnetic resonance imaging of subchondral bone marrow lesions in association with osteoarthritis.

Authors:  Li Xu; Daichi Hayashi; Frank W Roemer; David T Felson; Ali Guermazi
Journal:  Semin Arthritis Rheum       Date:  2012-04-26       Impact factor: 5.532

2.  Whole brain quantitative T2 MRI across multiple scanners with dual echo FSE: applications to AD, MCI, and normal aging.

Authors:  Corinna M Bauer; Hernán Jara; Ron Killiany
Journal:  Neuroimage       Date:  2010-05-02       Impact factor: 6.556

3.  A simple method for mapping the B1 field distribution of linear RF coils.

Authors:  Jan Weis; Peter Andris; Ivan Frollo; Håkan Ahlström
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

4.  Recovery of Damped Exponentials Using Structured Low Rank Matrix Completion.

Authors:  Arvind Balachandrasekaran; Vincent Magnotta; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2017-07-14       Impact factor: 10.048

5.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

6.  A comparative study at 3 T of sequence dependence of T2 quantitation in the knee.

Authors:  Alex Pai; Xiaojuan Li; Sharmila Majumdar
Journal:  Magn Reson Imaging       Date:  2008-05-23       Impact factor: 2.546

Review 7.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

8.  Fast T2 mapping with improved accuracy using undersampled spin-echo MRI and model-based reconstructions with a generating function.

Authors:  Tilman J Sumpf; Andreas Petrovic; Martin Uecker; Florian Knoll; Jens Frahm
Journal:  IEEE Trans Med Imaging       Date:  2014-12       Impact factor: 10.048

9.  Simultaneous measurement of T2 and apparent diffusion coefficient (T2 +ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging.

Authors:  Eric Aliotta; Kévin Moulin; Zhaohuan Zhang; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2017-05-17       Impact factor: 4.668

10.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.