Reproducibility of goniometry of the wrist.

S Solgaard, A Carlsen, M Kramhøft, V S Petersen.   

Abstract

The wrist motion in 31 healthy probands was measured by four observers with a simple goniometer under standardized conditions. The INTRA-observer variation was calculated to 5 to 8 degrees and the INTER-observer variation to 6 to 10 degrees. No difference between experienced and non-experienced observers was found. The difference between the right and the left wrist was negligible, indicating that the opposite wrist can be used as reference when evaluating restrictions in motion.

Mesh:

Year:  1986        PMID: 3715428

Source DB:  PubMed          Journal:  Scand J Rehabil Med        ISSN: 0036-5505


  8 in total

1.  Assessment of four midcarpal radiologic determinations.

Authors:  Mickey S Cho; Vincent Battista; Norman H Dubin; Miguel Pirela-Cruz
Journal:  Surg Radiol Anat       Date:  2005-12-09       Impact factor: 1.246

2.  Relationship between patient satisfaction and objective functional outcome after surgical treatment for distal radius fractures.

Authors:  Kevin C Chung; Ann Haas
Journal:  J Hand Ther       Date:  2009-06-26       Impact factor: 1.950

3.  New method of measuring wrist joint position sense avoiding cutaneous and visual inputs.

Authors:  Andre Gay; Kimberly Harbst; Kenton R Kaufman; Diana K Hansen; Edward R Laskowski; Richard A Berger
Journal:  J Neuroeng Rehabil       Date:  2010-02-10       Impact factor: 4.262

4.  Distal radius fractures in older patients: is anatomic reduction necessary?

Authors:  Andrew J Synn; Eric C Makhni; Melvin C Makhni; Tamara D Rozental; Charles S Day
Journal:  Clin Orthop Relat Res       Date:  2008-12-12       Impact factor: 4.176

5.  Flexibility of the shoulder joint measured as range of abduction in a large representative sample of men and women over 65 years of age.

Authors:  E J Bassey; K Morgan; H M Dallosso; S B Ebrahim
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

6.  Long-term functional donor site morbidity of the free radial forearm flap in head and neck cancer survivors.

Authors:  Jason R Orlik; Peter Horwich; Clark Bartlett; Jonathan Trites; Robert Hart; S Mark Taylor
Journal:  J Otolaryngol Head Neck Surg       Date:  2014-01-13

7.  Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis.

Authors:  Lisa Reissner; Gabriella Fischer; Renate List; William R Taylor; Pietro Giovanoli; Maurizio Calcagni
Journal:  J Orthop Surg Res       Date:  2019-06-10       Impact factor: 2.359

8.  Comparison of a New Inertial Sensor Based System with an Optoelectronic Motion Capture System for Motion Analysis of Healthy Human Wrist Joints.

Authors:  Michael Alexander Wirth; Gabriella Fischer; Jorge Verdú; Lisa Reissner; Simone Balocco; Maurizio Calcagni
Journal:  Sensors (Basel)       Date:  2019-12-01       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.