Literature DB >> 3706854

New methods for whole blood oximetry.

J M Schmitt, F G Mihm, J D Meindl.   

Abstract

New techniques for determining the hematocrit (Hct) and oxygen saturation (SO2) of whole blood from backscattered light measurements are described. First, theoretical and experimental results are presented which show that the empirical linear relationship between SO2 and the infrared-red backscattered light intensity ratio on which previous instruments have been based is an inadequate description primarily because it does not account for the strong effects of Hct and transducer geometry. Then it is shown that the ratio of backscattered intensities from two appropriately positioned infrared sources can be plotted against the infrared-red intensity ratio to produce a family of calibration curves from which SO2 and Hct can be independently determined. Finally, a practical implementation of an oximetry system which employs a microelectronic catheter-tip optical sensor and a microprocessor-based signal processor is proposed.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3706854     DOI: 10.1007/bf02364647

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  8 in total

1.  Diffuse reflectance from a finite blood medium: applications to the modeling of fiber optic catheters.

Authors:  L Reynolds; C Johnson; A Ishimaru
Journal:  Appl Opt       Date:  1976-09-01       Impact factor: 1.980

2.  Continuous monitoring of mixed venous oxygen saturation in man.

Authors:  W E Martin; P W Cheung; C C Johnson; K C Wong
Journal:  Anesth Analg       Date:  1973 Sep-Oct       Impact factor: 5.108

3.  Fibre optic reflection photometry on blood.

Authors:  G A Mook; P Osypka; R E Sturm; E H Wood
Journal:  Cardiovasc Res       Date:  1968-04       Impact factor: 10.787

4.  In vitro evaluation of an in vivo fiber-optic oximeter.

Authors:  E A Woodroof; S Koorajian
Journal:  Med Instrum       Date:  1973 Nov-Dec

5.  Clinical studies with a solid state fiberoptic oximeter.

Authors:  J S Cole; W E Martin; P W Cheung; C C Johnson
Journal:  Am J Cardiol       Date:  1972-03       Impact factor: 2.778

6.  A solid state fiberoptics oximeter.

Authors:  C C Johnson; R D Palm; D C Stewart; W E Martin
Journal:  J Assoc Adv Med Instrum       Date:  1971 Mar-Apr

7.  A fiberoptic reflection oximeter.

Authors:  M L Landsman; N Knop; G Kwant; G A Mook; W G Zijlstra
Journal:  Pflugers Arch       Date:  1978-03-20       Impact factor: 3.657

8.  Fiber optics for continuous in vivo monitoring of oxygen saturation.

Authors:  D C Harrison; N S Kapany; H A Miller; N Silbertrust; W L Henry; R P Drake
Journal:  Am Heart J       Date:  1966-06       Impact factor: 4.749

  8 in total
  1 in total

1.  Simultaneous in vivo comparison of two-versus three-wavelength mixed venous (Svo2) oximetry catheters.

Authors:  F Bongard; T S Lee; T Leighton; S Y Liu
Journal:  J Clin Monit       Date:  1995-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.