Literature DB >> 3700753

Artifacts from pulsatile flow in MR imaging.

W H Perman, P R Moran, R A Moran, M A Bernstein.   

Abstract

Previous investigators have examined the effect of blood flow on the apparent blood vessel signal intensity. These studies reported flow brightening and darkening effects within vessels. In this paper we have investigated another type of flow artifact, which originates from the pulsatile nature of blood flow. These flow artifacts have characteristic bright and dark "ghosting" patterns which appear close to small vessels, usually arteries, which are bright in slow flow. Similar to the amplitude-of-motion artifacts caused by patient motion (e.g., breathing and cardiac motion) the ghosting artifacts due to pulsatile flow are best characterized as frequency modulated spectral sidebands. The pulsatile artifacts can have both dark and bright structures and usually appear close to the "moving" vessel that generates the artifact. In this paper we present a study of the chief features of these pulsatile flow artifacts, and we develop a theoretical description of their origins in terms of "accidental" velocity-encodings that occur strongly in most magnetic resonance imaging sequences.

Entities:  

Mesh:

Year:  1986        PMID: 3700753

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  6 in total

1.  Transmission, attenuation and reflection of shear waves in the human brain.

Authors:  Erik H Clayton; Guy M Genin; Philip V Bayly
Journal:  J R Soc Interface       Date:  2012-06-06       Impact factor: 4.118

2.  Cardiac magnetic resonance imaging using radial k-space sampling and self-calibrated partial parallel reconstruction.

Authors:  Jingsi Xie; Peng Lai; Feng Huang; Yu Li; Debiao Li
Journal:  Magn Reson Imaging       Date:  2010-01-12       Impact factor: 2.546

3.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

4.  Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging.

Authors:  SoHyun Han; Congyu Liao; Mary Kate Manhard; Daniel Joseph Park; Berkin Bilgic; Merlin J Fair; Fuyixue Wang; Anna I Blazejewska; William A Grissom; Jonathan R Polimeni; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-12-16       Impact factor: 4.668

5.  Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases.

Authors:  Mie K Lam; Merel Huisman; Robbert J Nijenhuis; Maurice Aaj van den Bosch; Max A Viergever; Chrit Tw Moonen; Lambertus W Bartels
Journal:  J Ther Ultrasound       Date:  2015-03-24

Review 6.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

  6 in total