Cardiac magnetic resonance imaging using radial k-space sampling and self-calibrated partial parallel reconstruction.

Jingsi Xie1, Peng Lai, Feng Huang, Yu Li, Debiao Li.   

Abstract

Radial sampling has been demonstrated to be potentially useful in cardiac magnetic resonance imaging because it is less susceptible to motion than Cartesian sampling. Nevertheless, its capability of imaging acceleration remains limited by undersampling-induced streaking artifacts. In this study, a self-calibrated reconstruction method was developed to suppress streaking artifacts for highly accelerated parallel radial acquisitions in cardiac magnetic resonance imaging. Two- (2D) and three-dimensional (3D) radial k-space data were collected from a phantom and healthy volunteers. Images reconstructed using the proposed method and the conventional regridding method were compared based on statistical analysis on a four-point scale imaging scoring. It was demonstrated that the proposed method can effectively remove undersampling streaking artifacts and significantly improve image quality (P<.05). With the use of the proposed method, image score (1-4, 1=poor, 2=good, 3=very good, 4=excellent) was improved from 2.14 to 3.34 with the use of an undersampling factor of 4 and from 1.09 to 2.5 with the use of an undersampling factor of 8. Our study demonstrates that the proposed reconstruction method is effective for highly accelerated cardiac imaging applications using parallel radial acquisitions without calibration data. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20061114      PMCID: PMC2860029          DOI: 10.1016/j.mri.2009.12.018

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Coronary MR angiography: selection of acquisition window of minimal cardiac motion with electrocardiography-triggered navigator cardiac motion prescanning--initial results.

Authors:  Y Wang; R Watts; I Mitchell; T D Nguyen; J W Bezanson; G W Bergman; M R Prince
Journal:  Radiology       Date:  2001-02       Impact factor: 11.105

2.  3D coronary MR angiography in multiple breath-holds using a respiratory feedback monitor.

Authors:  Y Wang; R C Grimm; P J Rossman; J P Debbins; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

3.  Artifacts from pulsatile flow in MR imaging.

Authors:  W H Perman; P R Moran; R A Moran; M A Bernstein
Journal:  J Comput Assist Tomogr       Date:  1986 May-Jun       Impact factor: 1.826

4.  Respiratory effects in two-dimensional Fourier transform MR imaging.

Authors:  L Axel; R M Summers; H Y Kressel; C Charles
Journal:  Radiology       Date:  1986-09       Impact factor: 11.105

5.  Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.

Authors:  Y Wang; P J Rossman; R C Grimm; S J Riederer; R L Ehman
Journal:  Radiology       Date:  1996-01       Impact factor: 11.105

  5 in total
  3 in total

Review 1.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

2.  Sliding motion compensated low-rank plus sparse (SMC-LS) reconstruction for high spatiotemporal free-breathing liver 4D DCE-MRI.

Authors:  Wenyuan Qiu; Dongxiao Li; Xinyu Jin; Fan Liu; Thanh D Nguyen; Martin R Prince; Yi Wang; Pascal Spincemaille
Journal:  Magn Reson Imaging       Date:  2019-01-15       Impact factor: 2.546

3.  The Influence of Radial Undersampling Schemes on Compressed Sensing in Cardiac DTI.

Authors:  Jianping Huang; Wenlong Song; Lihui Wang; Yuemin Zhu
Journal:  Sensors (Basel)       Date:  2018-07-23       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.