Literature DB >> 3693806

[Fluorophotometry by instillation. I. Flow of the aqueous humor and corneal endothelial permeability].

L M Coulangeon1, J M Menerath, P Sole.   

Abstract

Among various fluorophotometric methods performed on the anterior segment, topical administration of fluorescein was developed. This local administration allows to measure the aqueous humor flow and the permeability of the corneal endothelial. The examinations are performed on a computerized fluorophotometer: the Fluorotron Master. This fluorophotometer has been designed to accurately measure fluorescein's concentrations into the eye and especially in aqueous humor and cornea. Anterior chamber adapter magnifies the scan for detailed work in the anterior chamber and lens. The Fluorotron is supplied with a cuvette holder and a cuvette which is adapted to the optical head for measuring the concentration of fluorescein in blood plasma or in buffered aqueous samples. A good linearity was obtained between the meter readings and the concentrations of fluorescein in phosphate buffer with pH 7.4, within the range between 1 ng and 1000 ng. Based upon the mathematical analysis of Yablonski the method by fluorescein instillation is simple and safe and gives the loss coefficient, ko, of the dye from the anterior chamber, the aqueous humor flow, F, and the endothelial transfer coefficient kc.ca. Calculations were carried out on twenty one normal eyes yielding average values for F 2.97 +/- 0.93 microliter.min-1 (Mean +/- S.D.) and for kc.ca 4.02 +/- 0.40. 10(-1) min-1. These values are comparable to those of other authors.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3693806

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  3 in total

1.  A fluorophotometric study on the aqueous humor dynamics in primary open angle glaucoma.

Authors:  P Beneyto Martin; P C Fernández Vila; T M Pérez Martinez; D Aliseda Peréz
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

2.  Comparative study of three methods of evaluation of the corneal endothelium in pseudophakic patients: fluorophotometry, specular microscopy and pachymetry.

Authors:  P Beneyto; R Gutierrez; T M Pérez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-10       Impact factor: 3.117

3.  Corneal endothelial permeability and aqueous humor flow using a standard protocol.

Authors:  J A van Best; M Diestelhorst; E Leite; S Fantaguzzi; R Schalnus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-09       Impact factor: 3.117