Literature DB >> 3688643

Diurnal variation of the diffusing capacity of the lung: is it real?

T M Frey1, R O Crapo, R L Jensen, C G Elliott.   

Abstract

The single-breath diffusing capacity of the lung (DLCO) has been reported to decrease at a rate of 1.2 to 2.2% per hour during usual daytime hours. In an attempt to confirm these findings, we measured DLCO using both single-breath (DLCOs) and rebreathing techniques (DLCOR) in healthy, nonsmoking volunteers over the course of a day and again at different times on different days. Serial testing over a day showed a consistent fall (0.39%/h for DLCOS and 0.56%/h for DLCOR) in DLCO that was explained by increasing carboxyhemoglobin levels (COHb) and decreasing hemoglobin concentrations (Hb). When subjects were tested at different times on different days and compared using a paired t test, there was no change in DLCO over the time of day using either technique. We conclude that there is no diurnal variation in DLCO when adjusted for changes in Hb and COHb. The measurement of COHb levels and Hb concentrations for adjustment of DLCO results is important for correct interpretation of both individual and group studies of DLCO and should be performed whenever possible.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3688643     DOI: 10.1164/ajrccm/136.6.1381

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  8 in total

1.  Calculating alveolar capillary conductance and pulmonary capillary blood volume: comparing the multiple- and single-inspired oxygen tension methods.

Authors:  Maile L Ceridon; Kenneth C Beck; Thomas P Olson; Jordan A Bilezikian; Bruce D Johnson
Journal:  J Appl Physiol (1985)       Date:  2010-06-10

2.  Acute effects of a single open sea air dive and post-dive posture on cardiac output and pulmonary gas exchange in recreational divers.

Authors:  Z Dujic; D Bakovic; I Marinovic-Terzic; D Eterovic
Journal:  Br J Sports Med       Date:  2005-05       Impact factor: 13.800

Review 3.  CO and NO pulmonary diffusing capacity during pregnancy: Safety and diagnostic potential.

Authors:  Gerald S Zavorsky; Arlin B Blood; Gordon G Power; Lawrence D Longo; Raul Artal; Emanuel J Vlastos
Journal:  Respir Physiol Neurobiol       Date:  2010-02-10       Impact factor: 1.931

4.  Diurnal variations in human pulmonary function.

Authors:  Boris I Medarov; Valentin A Pavlov; Leonard Rossoff
Journal:  Int J Clin Exp Med       Date:  2008-07-12

5.  Single breath transfer factor for carbon monoxide in an asymptomatic population of never smokers.

Authors:  A Gulsvik; P Bakke; S Humerfelt; E Omenaas; T Tosteson; S T Weiss; F E Speizer
Journal:  Thorax       Date:  1992-03       Impact factor: 9.139

Review 6.  Diffusing capacity.

Authors:  Matthew J Hegewald
Journal:  Clin Rev Allergy Immunol       Date:  2009-03-31       Impact factor: 8.667

7.  Comparison of Consistency, Feasibility, and Convenience of a Novel Compact System for Assessing Lung Volumes and Carbon Monoxide Diffusing Capacity versus Whole Body Plethysmography.

Authors:  Roberto W Dal Negro; Paola Turco; Massimiliano Povero
Journal:  Clinicoecon Outcomes Res       Date:  2021-07-07

8.  Intra-individual variation of particles in exhaled air and of the contents of Surfactant protein A and albumin.

Authors:  Spela Kokelj; Jeong-Lim Kim; Marianne Andersson; Gunilla Runström Eden; Björn Bake; Anna-Carin Olin
Journal:  PLoS One       Date:  2020-01-24       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.