Literature DB >> 3684230

Threshold Amsler grid testing in maculopathies.

M Wall1, D R May.   

Abstract

The Amsler grid is a suprathreshold target and thus may fail to detect relative scotomas. If the grid is viewed through two cross-polarizing filters creating low luminance conditions (threshold Amsler grid testing) the test is far more sensitive. Ten patients with disorders of the macula with normal standard white Amsler grid testing were studied with three other Amsler grid tests. Of the 15 involved eyes, 12 had visual field defects present with threshold Amsler grid testing. Tangent screen examination showed defects in 10 of these 12 eyes. The two red grids used were not as sensitive as the threshold grid. Three eyes had metamorphopsia with the white grid which became the site of a visual field defect with threshold testing. Threshold Amsler grid testing is a rapid and sensitive technique for the evaluation of the central 10 degrees of visual field in patients with maculopathies.

Entities:  

Mesh:

Year:  1987        PMID: 3684230     DOI: 10.1016/s0161-6420(87)33315-9

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Threshold Amsler grid testing in diabetic retinopathy.

Authors:  K A Wolfe; A A Sadun
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

2.  Quantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated threshold Amsler grid testing.

Authors:  Renu V Jivrajka; Janet K Kim; Wolfgang Fink; Alfredo A Sadun; J Sebag
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

3.  Orientation discrimination with macular changes associated with early AMD.

Authors:  Harold E Bedell; Jianliang Tong; Stanley Y Woo; Jon R House; Tammy Nguyen
Journal:  Optom Vis Sci       Date:  2009-05       Impact factor: 1.973

4.  Distinct patterns of spatial frequency response by normal, recovered optic neuritis, and normal fellow eyes to a new linearly variable neutral density device.

Authors:  E J Haupt; R Katz; P Chin; A A Cinotti; L Frohman
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993-02       Impact factor: 3.117

5.  Early detection of glaucoma by means of a novel 3D computer-automated visual field test.

Authors:  Paul P Nazemi; Wolfgang Fink; Alfredo A Sadun; Brian Francis; Donald Minckler
Journal:  Br J Ophthalmol       Date:  2007-05-15       Impact factor: 4.638

6.  A novel Bayesian adaptive method for mapping the visual field.

Authors:  Pengjing Xu; Luis Andres Lesmes; Deyue Yu; Zhong-Lin Lu
Journal:  J Vis       Date:  2019-12-02       Impact factor: 2.240

7.  Amsler grid test for detection of advanced glaucoma in Ethiopia.

Authors:  Girum W Gessesse; Lemlem Tamrat; Karim F Damji
Journal:  PLoS One       Date:  2020-03-10       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.