Literature DB >> 3677726

Comparative tonometric measurements of eye bank eyes.

A D Mendelsohn1, R K Forster, S L Mendelsohn, J J Dennis, D G Heidemann, I K Levine, J M Parel, J M Di Maio.   

Abstract

A comparison was made of the accuracy of the Tono-Pen, Pneumatonometer, and Perkins hand-held tonometers by measuring the hydrostatically controlled intracular pressure from 10 to 50 mm Hg in human eye bank eyes. The open stopcock method was used in which the cannulated eye, the hydrostatic pressure controlling column, and a manometer were continuously open to each other. The Pneumatonometer gave accurate results at 50 mm Hg but overestimated the lower intraocular pressures; whereas, the Perkins gave satifactory results at 10 and 20 mm Hg but underestimated higher intraocular pressures. The Tono-Pen displayed the least deviation from the controlled pressure over the entire range studied. Another aspect of this study involved determining that a therapeutic soft contact lens did not have any noticeably adverse effect on the accuracy of the Pneumatonometer and Tono-Pen tonometers.

Entities:  

Mesh:

Year:  1987        PMID: 3677726

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  6 in total

1.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

2.  Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level.

Authors:  Annette Troost; Kathrin Specht; Frank Krummenauer; Sung Hyun Yun; Oliver Schwenn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-15       Impact factor: 3.117

3.  Corneal hysteresis in patients with dry eye.

Authors:  P G Firat; S Doganay
Journal:  Eye (Lond)       Date:  2011-09-09       Impact factor: 3.775

4.  The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye.

Authors:  B K Pierscionek; M Asejczyk-Widlicka; R A Schachar
Journal:  Br J Ophthalmol       Date:  2006-12-06       Impact factor: 4.638

5.  The Magnitude of Hypotony and Time Course of Intraocular Pressure Recovery Following Anterior Chamber Cannulation in Nonhuman Primates.

Authors:  Jessica V Jasien; Carrie Huisingh; Christopher A Girkin; J Crawford Downs
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-06-01       Impact factor: 4.799

6.  Poor correlation between intracranial pressure and intraocular pressure by hand-held tonometry.

Authors:  Shani Golan; Shimon Kurtz; Daphna Mezad-Koursh; Michael Waisbourd; Anat Kesler; Pinchas Halpern
Journal:  Clin Ophthalmol       Date:  2013-06-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.