Literature DB >> 3677351

Measurement of myocardial blood flow by ultrafast computed tomography.

C J Wolfkiel1, J L Ferguson, E V Chomka, W R Law, I N Labin, M L Tenzer, M Booker, B H Brundage.   

Abstract

Myocardial blood flow was analyzed by radioisotope-labeled microspheres and ultrafast computed tomography (CT) in 16 closed-chest, anesthetized dogs. The first set of 10 dogs had CT and microsphere measurements before and after chromonar-induced increases in myocardial blood flow. A second set of six dogs had flows measured at control and during temporary reductions in regional flow produced by balloon cuff occlusion of the left anterior descending coronary artery. All dogs had four-slice, 20-instance CT scans after injection of a medium bolus (0.35 ml/kg) of contrast medium into a femoral vein simultaneous with injection of microspheres into the left atrium. CT myocardial flow was calculated as the change in myocardial CT numbers divided by the area from a blood pool time-density curve. A wide range of myocardial blood flows was produced as determined by microspheres (0 to 6.7 ml/min/g). Global flow of the first set of dogs was shown to have excellent correlation (r = .95, n = 17) for a limited range (.4 less than X less than 1.4 ml/min/g) of flows. Regional flows of these measurements demonstrated less correlation (r = .63, n = 110) but extended the range of flow to 1.7 ml/min/g. At higher flows (greater than 2.5 ml/min/g) the correlation for global and regional flows was not significantly different than zero. Regional ischemic flow correlation extended the linear range of flow to 0 ml/min/g (r = .62, n = 17). These results show that CT can measure myocardial blood flow over a limited but clinically relevant range of flows defined as slightly above normal to ischemic. These results indicate that another preparation of CT flow measurement must be sought for quantification of myocardial perfusion values significantly above normal.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3677351     DOI: 10.1161/01.cir.76.6.1262

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  28 in total

Review 1.  Ultrafast CT and the cardiovascular system.

Authors:  M S Bleiweis; D Georgiou; B H Brundage
Journal:  Int J Card Imaging       Date:  1992

2.  Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography.

Authors:  J Tobias Kühl; Jesper J Linde; Andreas Fuchs; Thomas S Kristensen; Henning Kelbæk; Richard T George; Jens D Hove; Klaus Fuglsang Kofoed
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-06       Impact factor: 2.357

3.  In vitro measurements of flow using multislice computed tomography (MSCT).

Authors:  Klaus Lackner; Henning Bovenschulte; Hartmut Stützer; Thomas Just; Hassan Al-Hassani; Barbara Krug
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-24       Impact factor: 2.357

Review 4.  Assessment of coronary blood flow with computed tomography and magnetic resonance imaging.

Authors:  Karl H Schuleri; Richard T George; Albert C Lardo
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 5.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

Review 6.  Computed tomography studies of lung ventilation and perfusion.

Authors:  Eric A Hoffman; Deokiee Chon
Journal:  Proc Am Thorac Soc       Date:  2005

Review 7.  Measurement of myocardial blood flow by UFCT: towards clinical applicability.

Authors:  C J Wolfkiel; B H Brundage
Journal:  Int J Card Imaging       Date:  1991

8.  Development of a theory for generating regional cardiac perfusion images during coronary angiography in the coronary angiography lab.

Authors:  Takuya Sakaguchi; Takashi Ichihara; Jeffrey C Trost; Omair Yousuf; Joao A C Lima; Jingwu Yao; Richard T George
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-12       Impact factor: 2.357

9.  CT coronary angiography: quantitative assessment of myocardial perfusion using test bolus data-initial experience.

Authors:  Ashley M Groves; Vicky Goh; Sabarinath Rajasekharan; Irfan Kayani; Raymondo Endozo; John C Dickson; Leon J Menezes; Manu Shastry; Said B Habib; Peter J Ell; Brian F Hutton
Journal:  Eur Radiol       Date:  2008-05-09       Impact factor: 5.315

Review 10.  Applications of cardiac multidetector CT beyond coronary angiography.

Authors:  Karl H Schuleri; Richard T George; Albert C Lardo
Journal:  Nat Rev Cardiol       Date:  2009-11       Impact factor: 32.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.