Pulse oximetry in preterm infants.

A Wasunna1, A G Whitelaw.   

Abstract

One hundred and twenty five measurements of arterial oxygen saturation (Stcao2) obtained with a transcutaneous pulse oximeter were compared with direct arterial oxygen tension (Pao2) in 13 preterm infants with predominantly fetal haemoglobin. Stcao2 of 86-92% corresponded to Pao2 of 5-13 kPa. Stcao2 above 92%, however, was sometimes associated with Pao2 above 13 kPa.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3674949      PMCID: PMC1778566          DOI: 10.1136/adc.62.9.957

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  5 in total

1.  Studies on erythro-kinetics in infancy. II. The relative rate of synthesis of haemoglobin F and haemoglobin A during the first months of life.

Authors:  L GARBY; S SJOLIN; J C VUILLE
Journal:  Acta Paediatr       Date:  1962-05       Impact factor: 2.299

2.  Directly measured arterial oxygen saturation in the newborn infant.

Authors:  C A Ryan; K J Barrington; D Vaughan; N N Finer
Journal:  J Pediatr       Date:  1986-09       Impact factor: 4.406

3.  Improved accuracy of continuous measurement of arterial oxygen tension in sick newborn infants. Criteria for reading and recalibrating the electrode.

Authors:  A R Wilkinson; R H Phibbs; G A Gregory
Journal:  Arch Dis Child       Date:  1979-04       Impact factor: 3.791

4.  Complications of umbilical oxygen electrodes.

Authors:  K R Kollmeyer; R C Tsang
Journal:  J Pediatr       Date:  1974-06       Impact factor: 4.406

5.  Noninvasive arterial hemoglobin oxygen saturation versus transcutaneous oxygen tension monitoring in the preterm infant.

Authors:  R Deckardt; D J Steward
Journal:  Crit Care Med       Date:  1984-11       Impact factor: 7.598

  5 in total
  9 in total

1.  High or low oxygen saturation for the preterm baby.

Authors:  N McIntosh
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-05       Impact factor: 5.747

2.  Pulse oximetry, severe retinopathy, and outcome at one year in babies of less than 28 weeks gestation.

Authors:  W Tin; D W Milligan; P Pennefather; E Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-03       Impact factor: 5.747

Review 3.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 4.  Home oxygen for children: who, how and when?

Authors:  I M Balfour-Lynn; R A Primhak; B N J Shaw
Journal:  Thorax       Date:  2005-01       Impact factor: 9.139

Review 5.  Uses and abuses of pulse oximetry.

Authors:  J T Moyle
Journal:  Arch Dis Child       Date:  1996-01       Impact factor: 3.791

6.  Monitoring oxygen in the newborn: saturation or partial pressure?

Authors:  P R Dear
Journal:  Arch Dis Child       Date:  1987-09       Impact factor: 3.791

7.  The pulse oximeter.

Authors:  M Sanklecha
Journal:  Indian J Pediatr       Date:  1993 May-Jun       Impact factor: 1.967

8.  The use of pulse oximetry in the prevention of hyperoxaemia in preterm infants.

Authors:  D P Cochran; N J Shaw
Journal:  Eur J Pediatr       Date:  1995-03       Impact factor: 3.183

Review 9.  Enhanced Monitoring of the Preterm Infant during Stabilization in the Delivery Room.

Authors:  Daragh Finn; Geraldine B Boylan; C Anthony Ryan; Eugene M Dempsey
Journal:  Front Pediatr       Date:  2016-03-31       Impact factor: 3.418

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.