Literature DB >> 3669093

Preoxygenation and pulse oximetry may delay detection of esophageal intubation.

A J McShane, J L Martin.   

Abstract

A case of delayed detection of esophageal intubation is described. Preoxygenation and pulse oximetry were used, and the first indication of tube misplacement was arterial desaturation indicated by the pulse oximeter. The combination of preoxygenation and pulse oximetry may contribute to delays in early detection of endotracheal tube misplacement for the following reasons: (1) preoxygenation results in a pulmonary reservoir of oxygen sufficient to maintain arterial hemoglobin saturation for an extended period of time; and (2) the maintenance of normal arterial saturations for an extended period after inadvertent esophageal tube placement may lead the practitioner to initially seek other causes of declining oxygen saturations. Although pulse oximetry is an acknowledged advance in patient monitoring, it must not be utilized as an early indication of correct endotracheal tube placement.

Entities:  

Mesh:

Year:  1987        PMID: 3669093      PMCID: PMC2625589     

Source DB:  PubMed          Journal:  J Natl Med Assoc        ISSN: 0027-9684            Impact factor:   1.798


  7 in total

1.  Endotracheal intubation: friend or foe.

Authors:  D B Scott
Journal:  Br Med J (Clin Res Ed)       Date:  1986-01-18

2.  Noninvasive detection of profound arterial desaturations using a pulse oximetry device.

Authors:  F G Mihm; B D Halperin
Journal:  Anesthesiology       Date:  1985-01       Impact factor: 7.892

3.  The Nellcor N-101 pulse oximeter. A clinical evaluation in anaesthesia and intensive care.

Authors:  J A Tytler; H F Seeley
Journal:  Anaesthesia       Date:  1986-03       Impact factor: 6.955

4.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

5.  Anesthesia in 1984: how safe is it?

Authors:  J M Davies; L Strunin
Journal:  Can Med Assoc J       Date:  1984-09-01       Impact factor: 8.262

6.  Pulse oximetry during one-lung ventilation.

Authors:  J B Brodsky; M S Shulman; M Swan; J B Mark
Journal:  Anesthesiology       Date:  1985-08       Impact factor: 7.892

7.  Signs of endotracheal intubation.

Authors:  T H Howells; R J Riethmuller
Journal:  Anaesthesia       Date:  1980-10       Impact factor: 6.955

  7 in total
  2 in total

1.  Alternative procedures for reducing allogeneic blood transfusion in elective orthopedic surgery.

Authors:  Kathrin Kleinert; Oliver M Theusinger; Johannes Nuernberg; Clément M L Werner
Journal:  HSS J       Date:  2010-01-28

Review 2.  Improving detection of patient deterioration in the general hospital ward environment.

Authors:  Jean-Louis Vincent; Sharon Einav; Rupert Pearse; Samir Jaber; Peter Kranke; Frank J Overdyk; David K Whitaker; Federico Gordo; Albert Dahan; Andreas Hoeft
Journal:  Eur J Anaesthesiol       Date:  2018-05       Impact factor: 4.330

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.