Literature DB >> 3663425

Detection of arrhythmias: use of a patient-activated ambulatory electrocardiogram device with a solid-state memory loop.

A P Brown1, K D Dawkins, J G Davies.   

Abstract

A patient-activated ambulatory electrocardiogram device with a solid-state memory loop was used to investigate 100 unselected patients experiencing palpitation, dizziness, or syncope. Clinically useful information was obtained in 68% of patients. Frequently, sinus rhythm had been restored by the time the patient activated the device, but the arrhythmia had been stored in the pre-event segment of the memory--a distinct advantage over many other patient-activated devices. This recorder is complementary to conventional 24 hour electrocardiographic monitoring in the investigation of possible arrhythmias and is particularly suitable for patients with infrequent symptoms. Because the stored data can be rapidly analysed by any commercially available electrocardiograph the device is suitable for use in district general hospitals.

Entities:  

Mesh:

Year:  1987        PMID: 3663425      PMCID: PMC1216445          DOI: 10.1136/hrt.58.3.251

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  7 in total

1.  Evaluation of outpatient arrhythmias utilizing transtelephonic monitoring.

Authors:  P Judson; D R Holmes; W P Baker
Journal:  Am Heart J       Date:  1979-06       Impact factor: 4.749

Review 2.  Lessons from ambulatory electrocardiography.

Authors:  M C Petch
Journal:  Br Med J (Clin Res Ed)       Date:  1985-09-07

3.  Current status of ambulatory electrocardiography.

Authors:  R A Winkle
Journal:  Am Heart J       Date:  1981-10       Impact factor: 4.749

4.  Diagnostic and therapeutic assessment by telephone electrocardiographic monitoring of ambulatory patients.

Authors:  Y Hasin; D David; S Rogel
Journal:  Br Med J       Date:  1976-09-11

5.  Detection of arrhythmia: limited usefulness of patient activated recording devices.

Authors:  L E Thomas; L M Shapiro; E J Perrins; K M Fox
Journal:  Br Med J (Clin Res Ed)       Date:  1984-10-27

6.  Arrhythmias in ambulatory persons. A review and experience of 1,000 consecutive recordings.

Authors:  A J Camm; D E Ward; R A Spurrell
Journal:  Biotelem Patient Monit       Date:  1978

7.  Role of 24-hour ambulatory electrocardiographic monitoring in a general hospital.

Authors:  A A McLeod; D E Jewitt
Journal:  Br Med J       Date:  1978-05-06
  7 in total
  12 in total

1.  Implantable loop recorder: evaluation of unexplained syncope.

Authors:  R A Kenny; A D Krahn
Journal:  Heart       Date:  1999-04       Impact factor: 5.994

Review 2.  [Electrophysiologic diagnosis and therapy].

Authors:  Guido Ritscher; Helge Simon; Georg Nölker; Johannes Brachmann; Anil-Martin Sinha
Journal:  Med Klin (Munich)       Date:  2010-06

3.  Paroxysmal Complete Atrioventricular Block: A Rare Cause of Syncope in Children.

Authors:  H Olgun; N Ceviz; T Karagoz
Journal:  West Indian Med J       Date:  2015-03-12       Impact factor: 0.171

Review 4.  Symptom/Rhythm Correlation With Patient Owned Device: Insights Into Practice And Challenges.

Authors:  Mohammed Shurrab; Anatoly Langer; Eugene Crystal; David Newman
Journal:  J Atr Fibrillation       Date:  2016-06-30

5.  Efficacy of diagnostic tools for detecting cardiac arrhythmias: systematic literature search.

Authors:  E Hoefman; P J E Bindels; H C P M van Weert
Journal:  Neth Heart J       Date:  2010-11       Impact factor: 2.380

6.  Prospective comparison of the diagnostic utility of a standard event monitor versus a "leadless" portable ECG monitor in the evaluation of patients with palpitations.

Authors:  Daniel Scherr; Darshan Dalal; Charles A Henrikson; David D Spragg; Ronald D Berger; Hugh Calkins; Alan Cheng
Journal:  J Interv Card Electrophysiol       Date:  2008-04-03       Impact factor: 1.900

7.  Use of a Patient-Activated Event Recording System in Patients with Tachycardic Palpitations: How Long to Follow Up?

Authors:  Philipp Attanasio; Martin Huemer; Lena Loehr; Abdul Shokor Parwani; Leif-Hendrik Boldt; Wilhelm Haverkamp; Alexander Wutzler
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-08-05       Impact factor: 1.468

Review 8.  [Latest proceedings: remote medicine - ready for clinical practice?!].

Authors:  Jörg O Schwab; Axel Müller; Michael Oeff; Jörg Neuzner; Stefan Sack; Dietrich Pfeiffer; Christian Zugck
Journal:  Herz       Date:  2008-09       Impact factor: 1.443

9.  Development of a diagnostic protocol for dizziness in elderly patients in general practice: a Delphi procedure.

Authors:  Otto R Maarsingh; Jacquelien Dros; Henk C van Weert; François G Schellevis; Patrick J Bindels; Henriette E van der Horst
Journal:  BMC Fam Pract       Date:  2009-02-07       Impact factor: 2.497

10.  Syncope: review of monitoring modalities.

Authors:  Rajesh Subbiah; Lorne J Gula; George J Klein; Allan C Skanes; Raymond Yee; Andrew D Krahn
Journal:  Curr Cardiol Rev       Date:  2008-02
View more