Literature DB >> 3660305

Effect of particle size of bronchodilator aerosols on lung distribution and pulmonary function in patients with chronic asthma.

D M Mitchell1, M A Solomon, S E Tolfree, M Short, S G Spiro.   

Abstract

The particle size of bronchodilator aerosols may be important in determining the site of deposition in the lung and their therapeutic effect. The distribution of aerosols (labelled with technetium-99m diethylene triamine pentacetic acid) of two different particle sizes has been studied by gamma camera imaging. The particles had mass median aerodynamic diameters (geometric standard deviations) of 1.4 (1.4) and 5.5 (2.3) micron, and they were administered from a jet nebuliser to eight patients with chronic severe stable asthma. There was no significant difference in peripheral lung deposition with the two aerosols in any patient. The bronchodilator effect of the two aerosols was determined from cumulative dose-response studies. To avoid large doses that might mask possible differences in effect due to aerosol size, small, precisely determined incremental amounts of salbutamol (25-250 micrograms total lung dose) were used. The two doses were given via a nebuliser on separate occasions and the bronchodilator response was measured from FEV1, forced vital capacity, and peak expiratory flow 30 minutes after each dose. Bronchodilatation was similar with the two aerosols at each dose of salbutamol. There was therefore no difference in distribution within the lung or any difference in bronchodilator effect between an aerosol of small (1.4 micron) particle size and an aerosol of 5.5 microns in patients with severe but stable asthma.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3660305      PMCID: PMC460779          DOI: 10.1136/thx.42.6.457

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  9 in total

Review 1.  Deposition of aerosol in the respiratory tract.

Authors:  J D Brain; P A Valberg
Journal:  Am Rev Respir Dis       Date:  1979-12

2.  Is driving gas flow rate clinically important for nebulizer therapy?

Authors:  J W Hadfield; W J Windebank; J R Bateman
Journal:  Br J Dis Chest       Date:  1986-01

3.  Factors influencing the size distribution of aerosols from jet nebulisers.

Authors:  M M Clay; D Pavia; S P Newman; S W Clarke
Journal:  Thorax       Date:  1983-10       Impact factor: 9.139

4.  The physiology of leaky lungs.

Authors:  J G Jones; B D Minty; D Royston
Journal:  Br J Anaesth       Date:  1982-07       Impact factor: 9.166

5.  Aerosols and humidity therapy. Generation and respiratory deposition of therapeutic aerosols.

Authors:  D L Swift
Journal:  Am Rev Respir Dis       Date:  1980-11

6.  Experimental determination of the regional deposition of aerosol particles in the human respiratory tract.

Authors:  W Stahlhofen; J Gebhart; J Heyder
Journal:  Am Ind Hyg Assoc J       Date:  1980-06

7.  A comparative study of two doses of salbutamol nebulized at 4 and 8 litres per minute in patients with chronic asthma.

Authors:  J G Douglas; M J Leslie; G K Crompton; I W Grant
Journal:  Br J Dis Chest       Date:  1986-01

8.  Experimental measurements and empirical modelling of the regional deposition of inhaled particles in humans.

Authors:  T L Chan; M Lippmann
Journal:  Am Ind Hyg Assoc J       Date:  1980-06

9.  Effect of aerosol particle size on bronchodilatation with nebulised terbutaline in asthmatic subjects.

Authors:  M M Clay; D Pavia; S W Clarke
Journal:  Thorax       Date:  1986-05       Impact factor: 9.139

  9 in total
  7 in total

Review 1.  In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review.

Authors:  Jolyon Mitchell; Steve Newman; Hak-Kim Chan
Journal:  AAPS PharmSciTech       Date:  2007-12-21       Impact factor: 3.246

2.  Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols.

Authors:  N Y Chew; H K Chan
Journal:  Pharm Res       Date:  1999-07       Impact factor: 4.200

3.  Bioequivalence of generic aerosol bronchodilators: what are the issues?

Authors:  M Spino
Journal:  CMAJ       Date:  1989-11-01       Impact factor: 8.262

4.  Regional Ventilation Is the Main Determinant of Alveolar Deposition of Coarse Particles in the Supine Healthy Human Lung During Tidal Breathing.

Authors:  Rui Carlos Sá; Kirby L Zeman; William D Bennett; G Kim Prisk; Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2017-03-09       Impact factor: 2.849

5.  Deposition patterns of aerosolized drugs within human lungs: effects of ventilatory parameters.

Authors:  T B Martonen; I M Katz
Journal:  Pharm Res       Date:  1993-06       Impact factor: 4.200

6.  Diagnostic value of lung clearance of 99mTc DTPA compared with other non-invasive investigations in Pneumocystis carinii pneumonia in AIDS.

Authors:  D S Robinson; D A Cunningham; S Dave; J Fleming; D M Mitchell
Journal:  Thorax       Date:  1991-10       Impact factor: 9.139

Review 7.  Interactions of particulate matter and pulmonary surfactant: Implications for human health.

Authors:  Feifei Wang; Jifang Liu; Hongbo Zeng
Journal:  Adv Colloid Interface Sci       Date:  2020-08-19       Impact factor: 12.984

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.