Literature DB >> 363740

Evaluation of routine subcultures of macroscopically negative blood cultures for detection of anaerobes.

P R Murray, J E Sondag.   

Abstract

Routine anaerobic subcultures of macroscopically negative blood culture bottles, performed within 1 day of receipt of the culture and after 5 days of incubation, were evaluated. Anaerobes were recovered from 207 (12.3%) of the total 1,688 positive cultures and, of these, 154 were only detected macroscopically, 11 only by subculture, and 42 by both procedures. In no instance was the anaerobe detected earlier with the subculture, and the time required for a definitive identification was reduced for only 10 isolates. Since the subcultures did not significantly improve the detection or early identification of anaerobes, routine anaerobic subcultures are not recommended.

Mesh:

Year:  1978        PMID: 363740      PMCID: PMC275265          DOI: 10.1128/jcm.8.4.427-430.1978

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Rapid detection of bacteremia by an early subculture technic.

Authors:  J K Todd; M H Roe
Journal:  Am J Clin Pathol       Date:  1975-11       Impact factor: 2.493

2.  Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles.

Authors:  J L Harkness; M Hall; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1975-10       Impact factor: 5.948

3.  Modification of the Minitek Miniaturized Differentiation System for characterization of anaerobic bacteria.

Authors:  D Stargel; F S Thompson; S E Phillips; G L Lombard; V R Dowell
Journal:  J Clin Microbiol       Date:  1976-03       Impact factor: 5.948

4.  Comparison of three blood culture media for recovery of anaerobic bacteria.

Authors:  J A Washington; W J Martin
Journal:  Appl Microbiol       Date:  1973-01

5.  Anaerobic bacteremia.

Authors:  W R Wilson; W J Martin; C J Wilkowske; J A Washington
Journal:  Mayo Clin Proc       Date:  1972-09       Impact factor: 7.616

6.  Presumptive diagnosis of anaerobic bacteremia by gas-liquid chromatography of blood cultures.

Authors:  J Wüst
Journal:  J Clin Microbiol       Date:  1977-12       Impact factor: 5.948

7.  Comparison of macroscopic examination, routine gram stains, and routine subcultures in the initial detection of positive blood cultures.

Authors:  D J Blazevic; J E Stemper; J M Matsen
Journal:  Appl Microbiol       Date:  1974-03

8.  Detection of bacteremia with liquid media containing sodium polyanetholsulfonate.

Authors:  M Hall; E Warren; J A Washington
Journal:  Appl Microbiol       Date:  1974-01

9.  Gram-negative rod bacteremia: microbiologic, immunologic, and therapeutic considerations.

Authors:  L S Young; W J Martin; R D Meyer; R J Weinstein; E T Anderson
Journal:  Ann Intern Med       Date:  1977-04       Impact factor: 25.391

  9 in total
  20 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures.

Authors:  D J Hardy; B B Hulbert; P C Migneault
Journal:  J Clin Microbiol       Date:  1992-10       Impact factor: 5.948

3.  Modification of the bile solubility test for rapid identification of Streptococcus pneumoniae.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1979-02       Impact factor: 5.948

Review 4.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

5.  Evaluation of a biphasic medium for blood cultures.

Authors:  M M Hall; C A Mueske; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1979-11       Impact factor: 5.948

6.  Relative recovery of anaerobes on different isolation media.

Authors:  J E Sondag; M Ali; P R Murray
Journal:  J Clin Microbiol       Date:  1979-11       Impact factor: 5.948

7.  Comparison of tryptic soy broth with tryptic soy broth supplemented with sucrose in the septi-chek blood culture system.

Authors:  M A Pfaller; L M Westfall; A C Niles; A Kinroth; P R Murray
Journal:  J Clin Microbiol       Date:  1983-02       Impact factor: 5.948

8.  Clinical laboratory comparison of a slide blood culture system with a conventional broth system.

Authors:  M A Pfaller; T K Sibley; L M Westfall; J E Hoppe-Bauer; M A Keating; P R Murray
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

9.  Lack of requirement for blind subcultures of BACTEC blood culture media.

Authors:  J C McLaughlin; J L Evers; J L Officer
Journal:  J Clin Microbiol       Date:  1981-11       Impact factor: 5.948

10.  Evaluation of two commercial blood culture media for the detection of blood-borne pathogens.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-01       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.