Literature DB >> 36271062

Intraoperative near-infrared lymphography with indocyanine green may aid lymph node dissection during robot-assisted resection of gastroesophageal junction cancer.

Jens Osterkamp1, Rune Strandby2, Nikolaj Nerup2, Morten-Bo Svendsen3, Lars-Bo Svendsen2, Michael Achiam2.   

Abstract

BACKGROUND: Adequate lymphadenectomy during gastroesophageal junction (GEJ) cancer resection is essential, because lymph node (LN) metastasis correlates with increased recurrence risk. Fluorescence lymphography with indocyanine green (ICG) has been used for LN mapping in several surgical specialties; however, reports on GEJ cancer are lacking. Therefore, we investigated whether intraoperative ICG lymphography could facilitate LN harvest during robot-assisted resection of GEJ cancer.
METHODS: Patients scheduled for robot-assisted resection of GEJ cancer were included, and outcomes were compared with historical controls. After intraoperative endoscopic submucosal ICG injection, standard D1 + LN dissection was performed under white light. Then, near-infrared (NIR) fluorescence imaging was activated, and each LN dissection area was re-examined. Any tissue within the D1 + field exhibiting distinctly increased ICG fluorescence compared with background tissue was dissected and sent for pathology review.
RESULTS: We included 70 patients between June 2020 and October 2021. Three cases were aborted due to disseminated disease, and two were converted to open resection and excluded from the analysis. Additional tissue was dissected after NIR review in 34 of 65 (52%) patients. We dissected 43 fluorescent tissue samples, and after pathology review, 30 were confirmed LNs; none were metastatic. The median number of LNs harvested per patient (34, interquartile range [IQR] = 26-44) was not significantly different from that harvested from historical controls (32, IQR = 24-45; p = 0.92), nor were there any differences between these two groups in the duration of surgery, intraoperative blood loss, or comprehensive complication scores (p = 0.12, p = 0.46, and p = 0.41, respectively).
CONCLUSIONS: Intraoperative NIR lymphography with ICG may aid LN detection during robot-assisted resection of GEJ cancer without increasing surgical risk. Although NIR lymphography may facilitate LN dissection, none of the LN removed after the NIR review was metastatic. Hence, it remains uncertain whether NIR lymphography will improve oncological outcomes.
© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Fluorescence; Fluorescence lymphography; Gastric cancer; Indocyanine green; Lymph node; Robotic surgery

Year:  2022        PMID: 36271062     DOI: 10.1007/s00464-022-09684-y

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   3.453


  2 in total

Review 1.  Surgical anatomy of gastric lymphatic drainage.

Authors:  Maria Carmen Lirosi; Alberto Biondi; Riccardo Ricci
Journal:  Transl Gastroenterol Hepatol       Date:  2017-03-01

2.  Prognostic predictors of patients with carcinoma of the gastric cardia.

Authors:  Ming Zhang; Zhigao Li; Yan Ma; Guanyu Zhu; Hongfeng Zhang; Yingwei Xue
Journal:  Hepatogastroenterology       Date:  2012-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.