| Literature DB >> 36258208 |
Xing Zheng1, Aixia Ma2, Jingai Huang2, Chunlan Liu3,4.
Abstract
BACKGROUND: The paper version of the training assessment was time-consuming and labor-consuming. It is an inevitable trend to change the appraisal method utilizing information technology. This study aimed to realize convenient and rapid management of the whole process of clinical nursing operation technology through information-based training and assessment platform.Entities:
Keywords: Assessment; Information system; Nursing; Operation technology; Training
Year: 2022 PMID: 36258208 PMCID: PMC9578263 DOI: 10.1186/s12912-022-01053-3
Source DB: PubMed Journal: BMC Nurs ISSN: 1472-6955
Summary of training and assessment attendance from 2018 to 2020 (n)
| Hierarchy | 2018 | 2019 | 2020 | |||
|---|---|---|---|---|---|---|
| training | assessment | training | assessment | training | assessment | |
| N1 | 292 | 287 | 260 | 254 | 238 | 238 |
| N2A | 238 | 233 | 279 | 272 | 242 | 242 |
| N2B | 402 | 390 | 242 | 236 | 260 | 260 |
| N2C | 656 | 300 | 396 | 386 | 221 | 221 |
| N3A | 440 | 440 | 314 | 304 | 652 | 652 |
| N3B | 374 | 244 | 272 | 272 | 604 | 604 |
| N3C | 420 | 384 | 492 | 492 | 172 | 172 |
| N3D | 480 | 430 | 382 | 382 | 679 | 679 |
| N3E | 492 | 492 | 344 | 344 | 247 | 247 |
| N4 | 982 | 982 | 1128 | 1128 | 419 | 419 |
| Total | 4776 | 4182 | 4109 | 4070 | 3734 | 3734 |
Summary of assessment attendance from 2016 to 2020
| Hierarchy | 2016 | 2017 | 2018 | 2019 | 2020 |
|---|---|---|---|---|---|
| N1 | 482 | 270 | 287 | 254 | 238 |
| N2 | 1480 | 1312 | 923 | 894 | 723 |
| N3 | 501 | 843 | 1990 | 1794 | 2354 |
| N4 | 490 | 632 | 982 | 1128 | 419 |
| Total | 2953 | 3057 | 4182 | 4070 | 3734 |
Comparative analysis of the same nurses’ performance in the same operation
| year | Nasal feeding | Blood transfusion | Micro pump | |||
|---|---|---|---|---|---|---|
|
| M( |
| M( |
| M( | |
| 2017 | 183 | 90.00(87.00,92.50) | 195 | 90.00(87.50,92.50) | 218 | 89.50(85.50,93.00) |
| 2018 | 142 | 91.00(88.00,93.00) | 118 | 92.75(90.50,94.50) | 185 | 93.00(90.50,94.88) |
|
| -1.733 | -5.264 | -7.456 | |||
|
| 0.083 | < 0.001 | < 0.001 | |||
Comparative analysis of operational errors of blood transfusion before and after using nursing Operation training information Platform
| Item | 2017( | 2018( | χ2 |
|
|---|---|---|---|---|
| Operation check is not standard | 407(52.17) | 92(19.49) | 131.075 | < 0.001 |
| Execution form signature and time are not standard | 323(55.21) | 36(10.17) | 189.487 | < 0.001 |
| Exhaust light check for bubbles | 236(60.51) | 55(23.30) | 81.824 | < 0.001 |
| Operation timeout | 157(80.51) | 113(95.76) | 14.427 | < 0.001 |
| The disinfection technique is not correct | 144(73.85) | 56(47.46) | 22.191 | < 0.001 |
Note: A total of 4 checks are required in this operation, so the total number of checks in 2017 is 195 * 4 = 780, and the total number of checks in 2018 is 118 * 4 = 472. Three checks are required to execute a single signature in the operation, thus, the total number of signatures in 2017 was 195 * 3 = 585, and the total number of signatures in 2018 was 118 * 3 = 354; the total number of exhaust-to-light inspections in 2017 was therefore 195 * 2 = 390, with 2 in-operation exhaust-to-light inspections; In 2018, the total number of exhaust light checks was 118 * 2 = 236
Comparative analysis of operational errors of micro pump before and after using nursing Operation training information Platform
| Item | 2017( | 2018( | χ2 |
|
|---|---|---|---|---|
| Operation check is not standard | 250(38.22) | 70(12.61) | 101.202 | < 0.001 |
| Incomplete explanation to patients | 113(51.83) | 32(17.30) | 51.279 | < 0.001 |
| The use of micro pump is not standard | 106(48.62) | 50(27.03) | 19.674 | < 0.001 |
| The extraction method is not standard | 84(38.53) | 52(28.11) | 4.864 | 0.027 |
| Operation timeout | 82(37.61) | 127(68.64) | 38.606 | < 0.001 |
Note: A total of 3 checks are required in this operation, so the total number of checks in 2017 is 218 * 3 = 654, and the total number of checks in 2018 is 185 * 3 = 555;
Summary and analysis of results of N1 nurses from 2016 to 2020
| year | Nasal feeding | CPR | breathing bag | Electrical shock | ||||
|---|---|---|---|---|---|---|---|---|
|
| M( |
| Mean(SD) |
| Mean(SD) |
| Mean(SD) | |
| 2016 | 205 | 91.00(88.00,94.50) | 64 | 91.71(1.82) | 69 | 92.30(2.70) | 74 | 90.63(2.35) |
| 2017 | 133 | 91.50(89.50,93.50) | 43 | 91.63(3.47) | 44 | 91.17(3.01) | 44 | 90.34(2.70) |
| 2018 | 145 | 93.00(90.00,95.00) | 49 | 91.67(2.71) | 47 | 93.57(2.84) | 51 | 90.76(3.46) |
| 2019 | 126 | 93.50(91.38,95.00) | 42 | 92.74(2.60) | 42 | 93.03(3.63) | 43 | 90.85(2.93) |
| 2020 | 119 | 93.50(92.00,95.00) | 61 | 94.17(2.02) | 38 | 93.59(3.42) | 42 | 91.67(2.60) |
|
| 72.948 | 11.379 | 4.867 | 1.329 | ||||
|
| 0.000 | < 0.001 | 0.001 | 0.260 | ||||