Literature DB >> 3621961

Comparison of pulsed Doppler and thermodilution methods for measuring cardiac output in critically ill patients.

K D Donovan, G J Dobb, M A Newman, B E Hockings, M Ireland.   

Abstract

We obtained 145 consecutive cardiac output measurements in 38 critically ill patients, using the invasive thermodilution and the noninvasive pulsed Doppler methods. The mean thermodilution cardiac output (TDCO) was 5.7 +/- 1.87 L/min and the mean pulsed Doppler cardiac output (PDCO) was 5.16 +/- 1.66 L/min. The mean difference between the two measurements was 0.51 L/min with an SD greater than 1.6 L/min, reflecting the scattering of results. The overall correlation coefficient was .58. The intercepts were large and the regression equation some way from the line of equal values (TDCO = 2.28 + 0.66 PDCO). When the results were analyzed according to diagnosis or by group experience, there were some differences in the bias of the estimate; however, the SD of the difference between methods was greater than one liter/min in all groups. Thus, the pulsed Doppler method failed to estimate accurately TDCO in critically ill patients.

Entities:  

Mesh:

Year:  1987        PMID: 3621961     DOI: 10.1097/00003246-198709000-00011

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  9 in total

1.  Doppler-derived mean aortic flow velocity in children: an alternative to cardiac index.

Authors:  M D Seear; L D'Orsogna; G G Sandor; E de Souza; R Popov
Journal:  Pediatr Cardiol       Date:  1991-10       Impact factor: 1.655

2.  Pharmacodynamic monitoring during acute intervention in ischaemic heart disease using a new echo-Doppler device.

Authors:  B Silke; S P Verma; S H Taylor
Journal:  Br J Clin Pharmacol       Date:  1990-06       Impact factor: 4.335

3.  Evaluation of cardiac function by echo-Doppler studies in critically ill patients.

Authors:  M Goldstein; J L Vincent; R J Kahn
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

4.  Dose-dependent heart rate reducing effect of nizatidine, a histamine H2-receptor antagonist.

Authors:  H Hinrichsen; A Halabi; G Fuhrmann; W Kirch
Journal:  Br J Clin Pharmacol       Date:  1993-05       Impact factor: 4.335

5.  Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants.

Authors:  C F Wippermann; D Schranz; R Huth; F Zepp; H Oelert; B K Jüngst
Journal:  Br Heart J       Date:  1992-02

6.  Descending aortic blood flow velocity as a noninvasive measure of cardiac output in children.

Authors:  M Seear; S Webber; J Leblanc
Journal:  Pediatr Cardiol       Date:  1994 Jul-Aug       Impact factor: 1.655

7.  The interaction of the calcium antagonist RO 40-5967 with digoxin.

Authors:  M Siepmann; C Kleinbloesem; W Kirch
Journal:  Br J Clin Pharmacol       Date:  1995-05       Impact factor: 4.335

8.  Haemodynamic comparison of amlodipine and atenolol in essential hypertension using the quantascope.

Authors:  T C Tham; N Herity; S Guy; B Silke
Journal:  Br J Clin Pharmacol       Date:  1993-12       Impact factor: 4.335

Review 9.  Equipment review: the success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation.

Authors:  Scott R Gunn; Mitchell P Fink; Benjamin Wallace
Journal:  Crit Care       Date:  2005-05-27       Impact factor: 9.097

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.