Subtle alterations in the high-frequency QRS potentials during myocardial ischemia in dogs.

S Abboud.   

Abstract

The high-frequency components in the QRS complex were examined before and during the occlusion of the left anterior descending coronary artery. ECG waveforms from different stages of the ischemia state were averaged using cross-correlation technique and fast Fourier transform algorithm. The average waveforms were the filtered with nonrecursive digital filters (150-250 Hz) to obtain the high-frequency QRS complex. We tested our nonrecursive digital filter for ringing and the trigger jitter during the averaging process. We demonstrated that the high-frequency signal left after filtering is the result of a subtle low-amplitude constituent of the QRS complex and that the morphological change during ischemia (as zone of reduced amplitude) is a result of changes in these components of the original ECG signal.

Entities:  

Mesh:

Year:  1987        PMID: 3621922     DOI: 10.1016/0010-4809(87)90052-8

Source DB:  PubMed          Journal:  Comput Biomed Res        ISSN: 0010-4809


  5 in total

1.  Intra-QRS spectral changes accompany ST segment changes during episodes of myocardial ischemia.

Authors:  Boris Gramatikov; Vivek Iyer
Journal:  J Electrocardiol       Date:  2014-09-16       Impact factor: 1.438

2.  Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG.

Authors:  O J Escalona; R H Mitchell; D E Balderson; D W Harron
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

3.  High-frequency QRS analysis in patients with acute myocardial infarction: a preliminary study.

Authors:  Guy Amit; Ori Galante; Linda R Davrath; Oded Luria; Shimon Abboud; Doron Zahger
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-11-22       Impact factor: 1.468

Review 4.  Frequency content and characteristics of ventricular conduction.

Authors:  Larisa G Tereshchenko; Mark E Josephson
Journal:  J Electrocardiol       Date:  2015-08-28       Impact factor: 1.438

5.  Improved detection of ischemic heart disease by combining high-frequency electrocardiogram analysis with exercise stress echocardiography.

Authors:  Jin-Oh Choi; Sung-A Chang; Sung Ji Park; Sang-Chol Lee; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.