| Literature DB >> 36211304 |
Hiba Al-Imam1,2, Ana R Benetti2, Pete Tomlins3, Klaus Gotfredsen1.
Abstract
Purpose: To evaluate the marginal and internal fit of lithium disilicate and zirconia crowns using two optical coherence tomography (OCT) systems in order to estimate inter-system variations. Materials and methods: Ten lithium disilicate and 10 cubic stabilized zirconia crowns were placed on prepared artificial teeth without cement. Marginal discrepancy and internal cement gap of the crowns were assessed on images obtained using a swept source OCT (SS-OCT) and a spectral domain OCT (SD-OCT). Medians and interquartile ranges were calculated for both materials and OCT systems. Thereafter, Wilcoxon signed rank test was carried out.Entities:
Keywords: Optical coherence tomography; lithium disilicate; zirconia
Year: 2022 PMID: 36211304 PMCID: PMC9543067 DOI: 10.1080/26415275.2022.2122468
Source DB: PubMed Journal: Biomater Investig Dent ISSN: 2641-5275
Figure 1.Experimental set-up using (a) the commercial SS-OCT (Santec IVS-300, Japan) and (b) the non-commercial SD-OCT (Queen Mary University of London, London, UK).
Figure 2.Details of measurement method: black lines cervically on the ceramic crown placed on the abutment tooth indicate the area for OCT imaging (left). B-scans (center) were obtained from five sites at the facial surface, 250 µm apart. On the B-scans, measurement sites were defined. Lines delimiting the marginal horizontal (a) and vertical (b) discrepancies were used to calculate the absolute marginal discrepancy (c), and measurement areas were delimited for assessment of internal fit. The internal cement gap was defined as the distance between two peaks on the gray value intensity plot (right).
Figure 3.Box-plots representing (a) absolute marginal discrepancy (µm) and (b) internal cement gap (µm) of lithium disilicate crowns assessed by SD-OCT and SS-OCT.
Figure 4.Box-plots representing (a) absolute marginal discrepancy (µm) and (b) internal cement gap (µm) of zirconia crowns assessed by SD-OCT and SS-OCT.
Median and interquartile ranges (IQR) of height of marginal gap (i.e. straight vertical line from preparation margin towards crown margin) and overextended margins (i.e. straight horizontal line from preparation margin towards facial surface of the crown) of lithium disilicate and zirconia crowns using Swept Source OCT (SS-OCT) and Spectral Domain OCT (SD-OCT).
| Height of gap median (IQR) | Overextended margin median (IQR) | |
|---|---|---|
| Lithium disilicate SS-OCT | 42 (95) | 179 (188) |
| Lithium disilicate SD-OCT | 64 (92) | 193 (89) |
| Zirconia SS-OCT | NIa | 116 (29) |
| Zirconia SD-OCT | NIa | 119 (153) |
The values are given in micrometer.
aNI: not identified with OCT.
Figure 5.Percentage of measured and missing internal cement gap values for lithium disilicate and zirconia crowns according both OCT system.