| Literature DB >> 36196310 |
Hui Zhao1, Adam Paxton1, Vikren Sarkar1, Ryan G Price1, Jessica Huang1, Fan-Chi Frances Su1, Xing Li1, Prema Rassiah1, Martin Szegedi1, Bill Salter1.
Abstract
PURPOSE: In this study, patient setup accuracy was compared between surface guidance and tattoo markers for radiation therapy treatment sites of the thorax, abdomen and pelvis. METHODS AND MATERIALS: A total of 608 setups performed on 59 patients using both surface-guided and tattoo-based patient setups were analyzed. During treatment setup, patients were aligned to room lasers using their tattoos, and then the six-degree-of-freedom (6DOF) surface-guided offsets were calculated and recorded using AlignRT system. While the patient remained in the same post-tattoo setup position, target localization imaging (radiographic or ultrasound) was performed and these image-guided shifts were recorded. Finally, surface-guided vs tattoo-based offsets were compared to the final treatment position (based on radiographic or ultrasound imaging) to evaluate the accuracy of the two setup methods.Entities:
Keywords: radiation therapy; rotation; surface-guided patient setup; tattoo-less setup; translation
Year: 2022 PMID: 36196310 PMCID: PMC9525098 DOI: 10.7759/cureus.28644
Source DB: PubMed Journal: Cureus ISSN: 2168-8184
Number of patients and treatment fractions in each treatment site
| Treatment site | # of patients | # of fractions | Percentage |
| Thorax | 25 | 202 | 33.2% |
| Abdomen / Pelvis | 34 | 406 | 66.8% |
| Total | 59 | 608 | 100% |
The average difference from IGRT positioning to either tattoo or surface-guided patient setup along the three principal directions.
| Treatment site | Averaged offset of tattoo | Averaged offset of surface-guidance | ||||
| Vert (cm) | Long (cm) | Lat (cm) | Vert (cm) | Long (cm) | Lat (cm) | |
| Thorax | 0.32±0.31 | 0.34±0.39 | 0.29±0.28 | 0.31±0.24 | 0.46±0.44 | 0.26±0.25 |
| Abdomen/pelvis | 0.41±0.32 | 0.34±0.33 | 0.29±0.26 | 0.55±0.42 | 0.75±0.66 | 0.36±0.35 |
| Overall | 0.38±0.32 | 0.34±0.35 | 0.29±0.26 | 0.47±0.39 | 0.66±0.61 | 0.32±0.32 |
The maximum IGRT shifts from tattoo and surface-guided patient setup along three principal directions.
| Treatment site | Maximum shift from tattoo | Maximum shift from surface-guidance | ||||
| Vert (cm) | Long (cm) | Lat (cm) | Vert (cm) | Long (cm) | Lat (cm) | |
| Thorax | 1.4 | 2.2 | 1.8 | 1.4 | 2.3 | 1.5 |
| Abdomen/pelvis | 1.8 | 1.9 | 1.5 | 2.2 | 4.3 | 3.3 |
Number of rotations in any direction recorded by the surface-guided setup in each range for each treatment site
| Treatment site | 3° – 5° | 5° – 10° | Over 10° |
| Thorax | 46 | 8 | 1 |
| Abdomen / Pelvis | 183 | 87 | 14 |
| Total | 229 (12.6%) | 95 (5.2%) | 15 (0.8%) |
Number of yaw, roll and pitch for rotations over 3° in each range for each treatment site
| Treatment site | Thorax | Abdomen / Pelvis | ||||
| yaw | roll | pitch | yaw | roll | pitch | |
| 3° – 5° | 14 | 9 | 23 (50%) | 54 | 23 | 106 (57.9%) |
| 5° – 10° | 1 | 2 | 5 (62.5%) | 10 | 9 | 68 (78.2%) |
| Over 10° | 0 | 1 | 0 | 2 | 1 | 11 (78.6%) |