| Literature DB >> 36188092 |
Richard Pham1, Alexander Sasha Ushinsky2, Naganathan Mani2, Pavan K Kavali2.
Abstract
The FlowTriever System (Inari Medical, Irvine, California) is the first FDA-approved mechanical thrombectomy device used for treatment of pulmonary embolism. This device enables nonsurgical removal of pulmonary blood clots without the use of thrombolytic medication and its associated risks. We report 2 cases of successful application of the Inari FlowTriever in treatment of pulmonary embolism and right atrial thrombus.Entities:
Keywords: FlowTriever; Inari; Mechanical thrombectomy; Pulmonary embolism
Year: 2022 PMID: 36188092 PMCID: PMC9520512 DOI: 10.1016/j.radcr.2022.08.081
Source DB: PubMed Journal: Radiol Case Rep ISSN: 1930-0433
Fig. 1(Case 1). CT imaging demonstrated bilateral segmental and subsegmental pulmonary emboli within the bilateral upper, middle, and lower lobe (arrows).
Fig. 2(Case 1). (A) Pre-PA Angio; (B) post-PA Angio.
Fig. 3(Case 2). Chest CT demonstrated acute pulmonary embolism with saddle embolus in the right pulmonary artery (arrow).
Fig. 4(Case 2). (A) Pre-PA Angio; (B) RPA post Angio; (C) LPA post Angio.