| Literature DB >> 36187755 |
James T Isaacs1, Philip J Almeter1,2, Bradley S Henderson1, Aaron N Hunter1, Thomas L Platt1, Robert A Lodder3.
Abstract
ULTIVA® (remifentanil hydrochloride) is a sterile, nonpyrogenic, preservative-free, white to off-white lyophilized powder for intravenous (IV) administration after reconstitution and dilution. Each vial contains 1, 2, or 5 mg of remifentanil base; 15 mg glycine; and hydrochloric acid to buffer the solutions to a nominal pH of 3 after reconstitution. ULTIVA® is a μ-opioid agonist with rapid onset and peak effect, and short duration of action. Intra-lot and inter-lot variability in the spectra of ULTIVA® was measured in the Drug Quality Study (DQS) using Fourier transform near-infrared spectrometry (FTNIR). In 6 vials sampled, 1 came from lot 220453F while 5 came from lot 30020BF. The 1 vial sampled from lot 220453F appeared 122 multidimensional SDs from the other vials from lot 30020BF, suggesting that it represents a different formulation or material. Consequently, additional spectra from other lots were analyzed. Spectra of 90 vials from 9 lots in the spectral library contained vials that were outside the main group (50.3 SDs using a subcluster detection test), suggesting that the 35 library vials (39% of the total) contain different materials from the other 55 vials.Entities:
Year: 2022 PMID: 36187755 PMCID: PMC9520611 DOI: 10.6084/m9.figshare.21109093
Source DB: PubMed Journal: Contact Context ISSN: 1547-8890