| Literature DB >> 36184592 |
Xiaofeng Zhou1, Chunya Ji2, Lingling Sun2, Linliang Yin3, Xuedong Deng4, Qi Pan2, Jun Zhang2, Zhong Yang2, Chenhan Zheng2, Chen Ling2, Liping Shi1, Yanqing Wu1.
Abstract
OBJECTIVES: To study the correlations between facial profile markers and crown-lump length (CRL) in a Chinese population, and to evaluate the clinical value of these markers for abnormal fetuses during the first trimester (11 to 13+6 gestational weeks).Entities:
Keywords: Abnormal fetuses; Facial profile; First trimester; Markers
Mesh:
Year: 2022 PMID: 36184592 PMCID: PMC9526988 DOI: 10.1186/s12884-022-05028-9
Source DB: PubMed Journal: BMC Pregnancy Childbirth ISSN: 1471-2393 Impact factor: 3.105
Fig. 1The measurement of IFA (86.91°); 12w6d, normal Chinese fetus
Fig. 2The measurement of MNM angle (4.7°); 13w1d, normal Chinese fetus
Fig. 3The measurement of FMA (72.53°); 13w3d, normal Chinese fetus
Fig. 4The measurement of FS distance (1.6 mm); 13w1d, normal Chinese fetus
Fig. 5The measurement of PL distance (3.1 mm); 13w1d, normal Chinese fetus
Fig. 6The measurements of each facial marker of trisomy 21 fetus; 12w5d. a IFA 75.03°; b MNM angle 2.75°; c FMA 68.89°; d FS distance 2.0 mm; e PL distance 2.5 mm
Fig. 7The measurements of each facial marker of trisomy 18 fetus; 12w4d. a IFA 66.52°; b MNM angle 10.63°; c FMA 62.13°; d FS distance 1.3 mm; e PL distance 2.5 mm
Fig. 8The measurements of each facial marker of CLP fetus; 13w1d. a IFA 81.91°; b MNM angle 6.92°; c FMA 71.04°; d FS distance 0 mm; e PL distance 2.3 mm
The mean (SD)/median (IQR) value for IFA, MNM angle, FMA, FS distance and PL distance in the normal fetuses and abnormal group, respectively
| Normal | Abnormal | |||
|---|---|---|---|---|
| Trisomy 21 | Trisomy 18 | CLP | ||
| IFA | 78.25° (74.75–82.98) | 74.11° (7.48) | 69.88° (7.08) | 82.03° (11.52) |
| MNM angle | 4.07° (3.21–5.29) | 4.59° (1.71) | 6.98° (2.61) | 9.41° (2.57) |
| FMA | 73.02° (5.01) | 74.33° (6.25) | 63.95° (4.77) | 74.42° (7.62) |
| FS distance | 1.97 mm (1.53–2.37) | 2.26 mm (0.85) | 1.70 mm (1.81) | -0.22 mm (1.38) |
| PL distance | 2.81 mm (0.53) | 2.89 mm (0.41) | 2.91 mm (0.56) | 2.71 mm (0.37) |
| Cases | 1000 | 14 | 7 | 10 |
IFA inferior facial angle, MNM angle maxilla-nasion-mandible angle, FMA facial maxillary angle, FS distance frontal space distance, PL distance profile line distance
Fig. 9ROC curve of IFA for trisomy 21 fetuses (a); IFA, MNM angle and FMA for trisomy 18 fetuses (b); MNM angle and FS distance for CLP fetuses (c)
The diagnostic value and cut-off of IFA for trisomy 21 fetuses; IFA, MNM angle and FMA for trisomy 18 fetuses; MNM angle and FS distance for CLP fetuses
| Trimosy 21 | Trimosy 18 | CLP | ||||
|---|---|---|---|---|---|---|
| IFA | IFA | MNM angle | FMA | MNM angle | FS distance | |
| AUC | 0.694 | 0.831 | 0.81 | 0.914 | 0.964 | 0.89 |
| 95% CI | 0.536 ~ 0.852 | 0.668 ~ 0.993 | 0.659 ~ 0.961 | 0.827 ~ 1 | 0.926 ~ 1 | 0.794 ~ 0.987 |
| Sensitivity | 0.643 | 0.704 | 0.933 | 0.85 | 0.912 | 0.868 |
| Specificity | 0.714 | 0.857 | 0.571 | 0.857 | 0.9 | 0.8 |
| Cut-off | 76.34° | 75.37° | 7.24° | 67.96° | 6.83° | 0.35 mm |
| 0.013a | 0.003a | 0.005a | ||||
AUC area under curve, CI confidence interval, CLP cleft lip and palate, IFA inferior facial angle, MNM angle maxilla-nasion-mandible angle, FMA facial maxillary angle, FS distance frontal space distance
aDenotes significant values if p < 0.05