Literature DB >> 36166431

A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: Evaluating feasibility in biomechanical simulation.

Hantao Ling1, Ravi Balasubramanian1.   

Abstract

Adult acquired flatfoot deformity becomes permanent with stage III posterior tibialis tendon dysfunction and results in foot pain and difficulty walking and balancing. To prevent progression to stage III posterior tibialis tendon dysfunction when conservative treatment fails, a flexor digitorum longus to posterior tibialis tendon transfer is often conducted. However, since the flexor digitorum longus only has one-third the force-capability of the posterior tibialis, an osteotomy is typically also required. We propose the use of a novel implantable mechanism to replace the direct attachment of the tendon transfer with a sliding pulley to amplify the force transferred from the donor flexor digitorum longus to the foot arch. In this work, we created four OpenSim models of an arched foot, a flatfoot, a flatfoot with traditional tendon transfer, and a flatfoot with implant-modified tendon transfer. Paired with these models, we developed a forward dynamic simulation of the stance phase of gait that reproduces the medial/lateral distribution of vertical ground reaction forces. The simulation couples the use of a fixed tibia, moving ground plane methodology with simultaneous activation of nine extrinsic lower limb muscles. The arched foot and flatfoot models produced vertical ground reaction forces with the characteristic double-peak profile of gait, and the medial/lateral distribution of these forces compared well with the literature. The flatfoot model with implant-modified tendon transfer produced a 94.2% restoration of the medial/lateral distribution of vertical ground reaction forces generated by our arched foot model, which also represents a 2.1X improvement upon our tendon transfer model. This result demonstrates the feasibility of a pulley-like implant to improve functional outcomes for surgical treatment of adult acquired flatfoot deformity with ideal biomechanics in simulation. The real-world efficacy and feasibility of such a device will require further exploration of factors such as surgical variability, soft tissue interactions and healing response.

Entities:  

Mesh:

Year:  2022        PMID: 36166431      PMCID: PMC9514661          DOI: 10.1371/journal.pone.0270638

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.752


Introduction

Traumatic injury or degeneration of the posterior tibialis (PT) tendon causes the foot arch to collapse and is one of the primary causes of adult acquired flatfoot deformity [1]. The PT tendon runs past the medial malleolus, inserts into the navicular tuberosity on the medial side of the foot, and acts as a key supporter of the medial longitudinal arch (see Fig 1A) [1, 2]. In stage III PT tendon dysfunction, as classified by Johnson and Strom [3], the flatfoot condition becomes permanent. This leads to foot pain, difficulty walking and balancing, and anatomical deformity. To avoid progression to stage III, conservative treatment, such as footwear and orthotics, are prescribed in stage II PT tendon dysfunction. However, in instances where conservative treatment is ineffective, surgical intervention is indicated.
Fig 1

Treatment options for adult acquired flatfoot deformity.

Drawings of (A) an arched foot, (B) a traditional FDL to PT tendon transfer surgery, and (C) our proposed implant-modified FDL to PT tendon transfer surgery.

Treatment options for adult acquired flatfoot deformity.

Drawings of (A) an arched foot, (B) a traditional FDL to PT tendon transfer surgery, and (C) our proposed implant-modified FDL to PT tendon transfer surgery. One of the common surgical procedures employed in the treatment of stage II PT dysfunction is a flexor digitorum longus (FDL) to PT tendon transfer surgery followed by a corrective osteotomy [1, 4–7]. In the tendon transfer surgery, the FDL tendon is separated from its natural insertion point on the lateral toes and directly attached to the navicular tuberosity to re-establish supporting forces to the medial longitudinal arch (see Fig 1B). Due to this direct coupling between the tendon and bone, the force transferred from the donor muscle to the host site is limited by the donor muscle’s force generating capacity; in this case, the FDL. Since the FDL generates less than one-third the force of the PT, the tendon transfer only partially restores the physiological supporting forces to the foot arch. Typically, the lack of strength of the transferred FDL is accepted because its primary function is to oppose foot eversion generated by the peroneus brevis muscle, which the FDL has two-thirds the strength of [8]. However, while the tendon transfer procedure alone leads to pain relief and improved inversion strength, the deformity often remains. This suggests that additional strength may be required in the transferred FDL to properly restore the foot arch and correct adult acquired flatfoot deformity. Due to the lack of candidate donor muscles and limitations in soft tissue surgery options, an additional osteotomy is currently required to fully correct the deformity and to optimize the biomechanics of the reconstructed PT tendon [1]. To address the limitations that arise in orthopedic surgery from using direct attachments, such as sutures, bone screws, and suture anchors, our group has previously developed a separate rod-shaped implantable mechanism that improves grasp function for patients with high median-ulnar nerve palsy [9, 10]. The device is implanted in the forearm between hand flexor tendons and redistributes the movement generated by a single muscle to multiple tendons by creating a “differential” tendon network. In this paper, we explore the feasibility of a different type of passive implantable mechanism in the early developmental stage that amplifies muscle force for the treatment of adult acquired flatfoot deformity. The novel implant will amplify the force transferred from the weaker FDL to the PT tendon by replacing the direct attachment between the tendons with a pulley-like device that provides mechanical advantage (see Fig 1C). Since the implant is passive, it eliminates the need for external power, electronics, motors, and control signals. Thus, the implant will enable the individual’s own muscle to generate the force and movement necessary to overcome the strength difference between the FDL and PT. If this device can be successfully developed and demonstrate efficacy in foot arch restoration, the force amplification provided by the implant has potential to restore supporting forces to the medial longitudinal arch beyond what is attainable with current surgical techniques. For the appropriate patients, the need for an additional osteotomy may be completely supplanted with the implant-based tendon transfer procedure. A preliminary human cadaver study conducted using this concept yielded promising results, with the implant-modified procedure leading to a significant medial shift of the center of pressure during the stance phase of gait [11]. However, evaluating the efficacy of surgical procedure and optimizing the design of surgical implants in cadaveric specimens is an extremely tedious process. Biomechanical simulations enable rapid design modification and provide immediate feedback regarding parameter sensitivity and post-operative outcomes. Since additional aspects of the implant design and surgical protocol need to be explored to fully evaluate the biomechanical feasibility of this implant-based procedure, this motivates the development of a biomechanical simulation capable of incorporating varying surgical protocols and foot pathologies while providing a measure of functional patient outcomes. We are especially interested in evaluating vertical ground reaction force distributions, which are a key parameter in both diagnosing foot pathologies [12-15] and retrospectively evaluating treatment efficacy [16, 17]. Surgical treatment of stage II adult acquired flatfoot deformity results in a quantifiable lateral shift of vertical ground reaction forces during the stance phase of gait [11, 18, 19]. However, there is currently a lack of lower extremity models that are capable of producing ground reaction force distributions during the stance phase of gait as outputs to simulation. Instead, ground reaction forces are primarily recorded experimentally and used as inputs in biomechanical simulations to estimate muscle forces and joint kinematics in inverse dynamic simulations [20, 21]. Thus, the models produced in this work seek to accurately generate vertical ground reaction forces of gait as an output variable to enable us to predict treatment outcomes under ideal circumstances defined in forward dynamic biomechanical simulation. Furthermore, a review of forty-one manuscripts showed that the current models did not emphasize the foot arch in dynamic gait simulation [22]. Specifically, current foot models have either three or four segments that include the hindfoot, midfoot, forefoot, and hallux, which only divide the foot into anterior and posterior sections. Without a degree of freedom between the medial and lateral sides of the foot, the height of the medial longitudinal arch cannot be easily adjusted between models, and the deformations of the arch cannot be properly accounted for in gait simulation. While models with a fully-defined medial longitudinal arch and passive ligaments do exist, these models are typically loaded statically and are not simulated in gait due to their complexity [23-25]. Modeling all the soft tissue and rigid body interactions in these complex models lead to heavy computational and time resource usage if applied to dynamic gait simulation. Conversely, simple models that are capable of accurately reproducing ground reaction forces during gait typically lack the detail to enable complex model modification to analyze various surgical treatment options or foot pathologies [26-30]. With reproduction of ground reactions forces as a main target for these models, anatomical definition is often abstracted away in favor of simplified mathematical models that reduce the computational strain and complexity in simulating dynamic gait. The aim of this paper is to create a forward dynamic biomechanical simulation of gait to determine the feasibility and efficacy of using a force-amplifying implantable mechanism in restoring the foot arch for individuals with adult acquired flatfoot deformity. The biomechanical models presented in this paper differ from previously developed gait models because they use forward dynamics to produce ground reaction forces throughout the stance phase of gait rather than use ground reaction force data as an input to inverse dynamic simulation. Our multi-segmented models also use a simplified medial longitudinal arch to enable arch height adjustment between models and arch deformation during gait simulation. This model feature is especially important since the severity of adult acquired flatfoot deformity correlates with a decrease in medial longitudinal arch height, which alters the medial/lateral distribution of vertical ground reaction forces over the plantar aspect of the foot throughout the stance phase of gait. In total, we have developed four foot models for simulation: (1) an arched foot, (2) a flatfoot with stage II adult acquired flatfoot deformity (henceforth called “flatfoot”), (3) a flatfoot with the traditional FDL to PT tendon transfer, and (4) a flatfoot with the implant-modified tendon transfer. These models were developed by modifying an existing lower limb model in OpenSim 3.3. OpenSim is a biomechanical simulation platform that has been used extensively to model lower extremity kinetics and kinematics [31-34]. The fidelity of the ground reaction force data generated by our simulations and models were compared with experimental results from prior work in the field. Specifically, we compare the overall ground reaction forces generated by the arched foot and flatfoot models to the literature, and we evaluate the differences in the medial/lateral distribution of vertical ground reaction forces created by our four foot models. The biomechanical efficacy of using a novel force-amplifying implant to treat adult-acquired flatfoot deformity was analyzed by comparing ground reaction force data generated by our implant-modified tendon transfer flatfoot model with data from the other three foot models.

Materials and methods

The lower-extremity models presented in this paper are based on cadaveric models from a collaborative study using a “Robotic Gait Simulator” to evaluate the feasibility and efficacy of a pulley-like device similar to the implant described in this paper [11]. The Robotic Gait Simulator is a six degree-of-freedom robot that reproduces the kinematics and kinetics of the stance phase of human gait in lower limb cadaver specimens [35]. The robot has been used previously to simulate both physiological and pathological gait [36, 37]. It replicates gait by actuating a ground plane with the inverse motion of gait relative to a lower-limb cadaveric specimen fixed at the tibia. The ground plane is instrumented with a force plate that records ground reaction forces through the simulated stance phase of gait. While the gait kinematics are reproduced through the ground plane, linear actuators simultaneously coordinate the “activation” of nine lower limb tendons: the PT, FDL, anterior tibialis, extensor digitorum longus, extensor hallicus longus, peroneus longus, peroneus brevis, flexor hallicus longus, and the Achilles. In the cadaver study, stage II adult acquired flatfoot deformity models were simulated by collapsing the medial longitudinal arch through ligament attenuation followed by cyclic weight-bearing loading. Three of the experimental groups developed from this cadaveric flatfoot model were an untreated flatfoot, a flatfoot treated with a FDL to PT tendon transfer surgery, and a flatfoot treated with an implant-modified tendon transfer surgery. The computational models described in this paper seek to replicate these three flatfoot models and provide an additional arched foot model for comparison. Like the Robotic Gait Simulator, the biomechanical simulation discussed in this paper uses a moving ground plane, lower limb models fixed at the tibia, and simultaneous activation of nine extrinsic lower limb muscles while recording ground reaction forces between the foot models and the ground plane. These modifications greatly simplify a full-body gait model down to a single limb actuated by nine muscles while retaining the complex kinematics and kinetics associated with ground reaction force generation during the stance phase of gait (see Fig 2). The two primary components of the biomechanical simulation are (1) the foot models and (2) the simulation of gait kinematics and kinetics. Further details on the development of these components are described in the following sections.
Fig 2

Foot model overview.

Modified lower limb model of an arched foot truncated at the femur with nine extrinsic muscles (blue) and five spheres (pink) for generating contact with a moving ground plane.

Foot model overview.

Modified lower limb model of an arched foot truncated at the femur with nine extrinsic muscles (blue) and five spheres (pink) for generating contact with a moving ground plane.

Foot models

The four foot models presented in this paper (arched foot, flatfoot, flatfoot with tendon transfer surgery, and flatfoot with implant-modified tendon transfer surgery) are modified versions of Stanford’s Gait2392 full-body model. The original OpenSim model represents a healthy adult subject with normal joint function and without adult acquired flatfoot deformity, so the foot models presented in this work are constrained by the base model they are developed from. Since the properties of the original model were not designed to replicate pathological function, the expected compensatory adaptions of tendons and muscles to adult acquired flatfoot deformity are not represented. However, this limitation does not prevent between-model comparisons from being drawn from the simulations. The Gait2392 model contains seventy-six muscles in the torso and lower extremities [31]. Inertial properties of the bones were inherited from the original model, which uses adapted experimental values from a previously developed computational model [38]. To minimize simulation complexity, our models are truncated at the knee joint and include bones from only the right lower limb. We can still fully simulate the stance phase of gait with this simplification because our methodology takes advantage of foot models fixed in space at the tibia while a moving ground plane tracks the inverse motion of gait. This modification reduces the seventy-six muscles in the original model to nine extrinsic muscles of the lower limb: the PT, FDL, anterior tibialis, extensor digitorum longus, extensor hallicus longus, flexor hallicus longus, peroneus longus, peroneus brevis, and soleus. Four joints are included in each of the foot models. The ankle, subtalar, and metatarsophalangeal joints are inherited from the original Gait2392 model while a simplified medial longitudinal arch joint was created as part of this work. The three joints included with the original model rotate about axes defined in the original model [31]. The foot arch joint is parallel to the sagittal plane in the midfoot and divides the first metatarsal and phalanx from the second to fifth metatarsals and phalanges. This additional arch joint combined with the model’s existing metatarsophalangeal joint results in four distinct sections of the foot (see Fig 3). The medial (first phalanx to navicular) and lateral (second through fifth phalanges to calcaneus) halves of the foot can rotate independently from each other about the foot arch joint. The first phalanx and second through fifth phalanges can flex independently of each other about the metatarsophalangeal joint, which was split at the intersection of the arch joint. Decreasing the angle of the arch joint raises the medial longitudinal arch while increasing the angle relaxes the medial longitudinal arch and flattens the foot.
Fig 3

Foot model segments and contact geometries.

Foot model developed for the gait simulations with four distinct segments: medial midfoot (red), medial forefoot (white), lateral midfoot (blue), and lateral forefoot (green). Five spheres used for generating contact forces between the foot and ground plane (pink) and the joints between foot segments (black lines) are also shown.

Foot model segments and contact geometries.

Foot model developed for the gait simulations with four distinct segments: medial midfoot (red), medial forefoot (white), lateral midfoot (blue), and lateral forefoot (green). Five spheres used for generating contact forces between the foot and ground plane (pink) and the joints between foot segments (black lines) are also shown. In the arched foot model, the arch joint angle was maintained from the original Gait2392 model. In the flatfoot models, the arch joint was flattened according to an 8 mm difference in first metatarsocuneiform height typically observed between arched feet and flatfeet [6, 39]. In addition to considering the skeletal geometry in our simplified foot arch model, we also included a simple model of the medial longitudinal arch’s elasticity, which is crucial for energy storage during gait [40]. The foot arch’s elasticity is typically provided by the passive deltoid and spring ligaments in the foot and the attachment of the posterior tibialis muscle onto the navicular bone [41]. In our foot models, we simplify the elasticity produced by the passive foot ligaments with a torsional stiffness of 1 Nm/° applied at the arch joint. For the four foot models, the paths of the nine extrinsic muscles remained consistent with the original Gait2392 model. Modifications to the PT and FDL muscles were made when appropriate to physiologically replicate each condition. In the arched foot model, no modifications were made to the routing of the muscles and tendons (see Fig 4A). In the flatfoot model, the PT muscle was disabled to simulate PT tendon dysfunction in stage II adult acquired flatfoot deformity, resulting in no PT muscle force being transferred to the navicular bone (see Fig 4B). In the flatfoot model with tendon transfer surgery, the FDL muscle was disabled to simulate removal of the FDL tendon from its original insertion. FDL forces were instead applied through the PT muscle, which maintained its original muscle path terminating on the navicular bone. Consequently, the original PT now acts as the transferred FDL in the tendon transfer model (see Fig 4C).
Fig 4

Overview of the four foot models.

The stance phase of gait was simulated with forward dynamics using (A) an arched foot model, (B) a flatfoot model, (C) a flatfoot with FDL tendon transfer model, and (D) a flatfoot with FDL tendon transfer and implant model. Only the routing of the flexor digitorum longus (FDL) and posterior tibialis (PT) are shown for clarity.

Overview of the four foot models.

The stance phase of gait was simulated with forward dynamics using (A) an arched foot model, (B) a flatfoot model, (C) a flatfoot with FDL tendon transfer model, and (D) a flatfoot with FDL tendon transfer and implant model. Only the routing of the flexor digitorum longus (FDL) and posterior tibialis (PT) are shown for clarity. In the flatfoot model with implant-modified tendon transfer surgery, the FDL muscle was again disabled to simulate its use as the donor tendon in tendon transfer surgery. The PT, which now acts the transferred FDL, was rerouted to represent the implant-modified tendon transfer. Rather than route the transferred FDL directly to the navicular bone, it is routed around the pulley implant, pulled back parallel with the proximal portion of the transferred FDL, and then anchored onto the tibia. The original tendon length of the transferred FDL was maintained during modification of the muscle path. An artificial tendon was then introduced into the model with one end fixed on the implant and the other end attached to the original insertion point of the PT tendon on the navicular bone (see Fig 4D). Due to the degradation of the original PT tendon, this artificial tendon in the foot models represents either grafted tendon or artificial tendon that will be required to make this attachment clinically. The movement of the implant within this model is constrained to the sagittal plane. This simplification was made because we assume the implant operates in its intended design without twisting or rotating and to reduce simulation complexity. After the transfer, FDL activation will cause its tendon to pull and slide on the implant, resulting in proximal translation of the implant. This artificially-created tendon network now acts like a pulley system and amplifies the force generated by the FDL, which is then transferred to the foot arch (see Fig 5). Fundamental physics dictates that the trade-off for the mechanical advantage provided by the implant is a proportional loss of excursion. Thus, 2X the excursion of the transferred FDL tendon is required to produce 2X the force at the insertion of the PT tendon and the same excursion as the original PT. In the ideal conditions created by this model, the implant creates a force amplification of 2X. In reality, the force amplification depends on several parameters, including FDL anchoring location, anchoring method, and tendon-implant friction. However, these parameters are beyond the scope of this paper, which aims to purely evaluate the initial feasibility and efficacy of such an implant under ideal circumstances in biomechanical simulation.
Fig 5

Diagram of the force amplification created by the implant-based tendon transfer surgery.

The tendon network created by the implant forms a pulley system that amplifies the force generated by the transferred flexor digitorum longus muscle as it is routed to the navicular bone.

Diagram of the force amplification created by the implant-based tendon transfer surgery.

The tendon network created by the implant forms a pulley system that amplifies the force generated by the transferred flexor digitorum longus muscle as it is routed to the navicular bone. The model parameters that were not mentioned as modifications of the original Gait2392 model, such as bone geometry and muscle force-length curves, were kept consistent across all four models described in this paper.

Gait simulation kinetics and kinematics

To generate vertical ground reaction force distributions for each of the four foot models, a simulation of the stance phase of gait was developed. The simulation consists of three primary components: coordinated muscle activations, ground plane kinematics, and contact dynamics between the ground plane and foot. During the simulated stance phase of gait, muscle forces are generated for the nine extrinsic muscles in our foot models (PT, FDL, anterior tibialis, extensor digitorum longus, extensor hallicus longus, flexor hallicus longus, peroneus longus, peroneus brevis, and soleus). The muscle forces are derived from electromyography-based estimates of muscle activation from a healthy population defined in previous studies using the Robotic Gait Simulator [35, 37, 42, 43]. The activation levels were defined at ten evenly distributed points throughout the stance phase of gait. The time histories of the muscle forces for the arched foot were generated in OpenSim for the entire stance phase of gait by linearly interpolating between these ten points and taking a product between each muscle’s activation curves and their maximum isometric force (see Fig 6). While the piecewise linear nature of these presented muscle forces do not mimic physiological muscle force patterns, we prefer to use this low resolution data because it is coupled with the kinematic data from the Robotic Gait Simulator studies we are mirroring with our simulations. We recognize that this is a limitation of our study. However, because all four of our foot models are actuated with the same methodology, we remain confident in our ability to make between-model comparisons.
Fig 6

Generated muscle forces.

Forces generated by nine extrinsic muscles of the lower limb during simulation of the stance phase of gait.

Generated muscle forces.

Forces generated by nine extrinsic muscles of the lower limb during simulation of the stance phase of gait. In the flatfoot model, the same muscle activations as the arched foot were used with the exception of the PT, which was not activated to simulate PT tendon dysfunction [11, 44]. While compensatory muscle activations are likely to develop in adult acquired flatfoot deformity, directly removing the PT forces in this manner enables us to isolate the effects that a dysfunctional PT tendon may have on shifting vertical ground reaction forces during gait compared to our arched foot model. In the two treatment models (flatfoot with tendon transfer and flatfoot with implant-modified tendon transfer), the FDL muscle forces shown in Fig 6 were applied to the original PT muscle path to represent the new transferred FDL tendon. In this scenario, we assume that there are no negative effects of tendon re-routing introduced during surgery for the flatfoot with traditional tendon transfer surgery model because the path of the transferred FDL exactly matches that of the original PT. This enables us to evaluate the efficacy of our implantable device compared to an ideal surgical scenario. The original FDL muscle was not activated, and all other muscles were actuated with the same activation curves as previously discussed for the arched foot and flatfoot models. By maintaining these muscle activation curves across the four models, we can more clearly evaluate how the FDL tendon transfer and implant-modified tendon transfer models shift vertical ground reaction force distributions during gait when compared to our base flatfoot and arched foot models. These simplifications in muscle activations and tendon routing in our models enable us to initially determine the feasibility and efficacy of a force-amplifying implant when compared to similar models under ideal circumstances. Since all the foot models are fixed in space at the tibia, gait kinematics are reproduced by applying the inverse motion of the stance phase of gait through a rectangular ground plane. This decision to generate gait kinematics through the ground plane greatly simplifies our simulation because we circumvent the need to control the complex dynamics of accelerating a full-body skeletal model. Instead, the simple ground plane drives gait kinematics, so we can reduce the full-body model to a single lower-limb skeletal model. Because of this methodology, full dorsiflexion to plantarflexion range of motion is achieved in simulation even with the excursion trade-off produced by the implant mechanics. While the active range of motion of the foot models is not explored in this study, a separate gait study using the Robotic Gait Simulator and human lower limb cadavers showed that the implant-based procedure did not cause the FDL muscle to exceed its physiological excursion limits [11]. The prescribed motion of the ground plane was generated by fitting polynomial curves to experimental data tracking three translational and three rotational coordinates from a previous cadaver study of adult acquired flatfoot deformity using the Robotic Gait Simulator [11, 35]. The ground plane began in contact with the heel (heel-strike) and ended in contact with the hallux (toe-off). The simulated stance phase kinematics are based off the cadaver study and lasts 4.09 s. This duration is about one-sixth the speed of physiologic gait and was originally used to protect the integrity of the cadaveric specimens [11]. The same kinematic trajectory of the ground plane was used in the simulation of all four foot models to remain consistent with the experimental methods used by the Robotic Gait Simulator and is shown in Fig 7. A visual progression of the arched foot model through the described kinematic trajectory of the ground plane is provided in Fig 8.
Fig 7

Ground plane kinematics.

Kinematic trajectory of the ground plane used as an input to gait simulation. (A) shows the local coordinate axes of the ground plane with respect to the orientation of a foot model. The input kinematic trajectory is split into (B) translational and (C) rotational components.

Fig 8

Simulation of stance phase of gait.

Gait simulation kinematics of the stance phase of gait through a healthy foot model. The tibia of the model is held fixed while a moving ground plane tracks the inverse motion of gait at heel strike, early midstance, late midstance, and toe off.

Ground plane kinematics.

Kinematic trajectory of the ground plane used as an input to gait simulation. (A) shows the local coordinate axes of the ground plane with respect to the orientation of a foot model. The input kinematic trajectory is split into (B) translational and (C) rotational components.

Simulation of stance phase of gait.

Gait simulation kinematics of the stance phase of gait through a healthy foot model. The tibia of the model is held fixed while a moving ground plane tracks the inverse motion of gait at heel strike, early midstance, late midstance, and toe off. The contact between the ground plane and the foot models was simulated using an elastic foundation force contact model [45]. This model uses a layer of triangular meshes covered with springs that independently interact with other objects in contact with the mesh, which enables application of both stiffness and friction characteristics. Stiffness values for the contact objects were adjusted until realistic deformations of the foot pads during gait were attained (peak of approximately 1 cm [46-48]). We assumed that the foot would not slip while in contact with the ground, so we used a very high friction coefficient to prevent slip between contact spheres on the foot models and the ground plane and to simplify computation during simulation. A viscous friction model is provided in OpenSim and is defined as F = F F v, where F is normal force, F is the coefficient of viscous friction, and v is the slip velocity. Contact forces were defined between designated contact objects placed on both the ground plane and the foot models. For the ground plane, a rectangular contact object with the same dimensions as the ground plane was defined as the contact object. For each foot model, five contact spheres were placed on the foot’s plantar aspect (see Fig 3). The sizing and placement of the contact spheres were approximated based on ellipsoidal contact volumes on the foot model developed by Brown and McPhee that reproduces ground-contact forces in forward dynamic simulation [48]. In their model, the size of the ellipsoids was determined based on a 70 kg subject. Since our model represents a larger, 82 kg subject, we increased the size of each of our spheres by 1 cm. We also split the metatarsal ellipsoid created in their work into two individual spheres and added an additional sphere at the fifth toe to enable evaluation of the medial/lateral distribution of vertical ground reaction forces. Specifically, we placed one 6 cm sphere at the heel while the four remaining spheres were placed to measure contact in each of the four foot segments at the first metatarsal head (4 cm), fifth metatarsal head (3 cm), hallux (3 cm), and fifth toe (2 cm). The placement of the spheres creates contact points around the foot perimeter and between each of the four segments of the foot model and the ground plane. A body weight loading of approximately 82 kg was applied to each of the foot models. This was accomplished by iteratively adjusting the initial distance between the foot models and the ground plane. At zero-percent stance phase, the heel contact sphere was set to intersect the ground plane such that the magnitude of the double-peak profile of vertical ground reaction forces represented that of an 82 kg individual’s gait. Contact between the foot models and the ground plane was maintained throughout stance phase via the ground plane kinematic trajectory, muscle activations, and friction between foot models and the ground plane. No other soft tissue interactions were included as part of the simulation. This contact model for the foot greatly simplifies the complex contact dynamics of gait while enabling the focus of this paper; namely, the evaluation of the medial-lateral distribution of vertical ground reaction forces throughout the stance phase of gait [49].

Results

The simulations presented in this paper produced two results: (Result 1) an analysis of our simulation methodology for generating vertical ground reaction forces during the stance phase of gait using our arched foot and flatfoot models; and (Result 2) a predictive comparison of treatment efficacy between a traditional tendon transfer procedure and our implant-based procedure for adult acquired flatfoot deformity. All ground reaction forces are normalized by body weight.

Vertical ground reaction force generation analysis

The arched foot and flatfoot model simulations for generating vertical ground reaction forces were evaluated using two parameters: the overall vertical ground reaction force curves that were produced and the difference in the distribution of vertical ground reaction forces between the medial and lateral sides of the foot. The overall vertical ground reaction forces generated by our simulations exhibit the characteristic double-peak profile of human gait (see Fig 9). They were plotted as the sum of vertical forces recorded by the five contact spheres on each foot model. In the arched foot simulation, the first peak in vertical ground reaction force occurs at 29.7% stance phase with a magnitude of 1.14 times body weight. In the flatfoot simulation, the first peak occurs at 30.8% stance phase with a magnitude of 1.09 times body weight. The second peak for the arched foot simulation appears with a magnitude of 1.07 times body weight at 73.0% stance phase, while the second peak in the flatfoot simulation appears with a magnitude of 1.16 times body weight at 72.3% stance phase. The minimum between the two peaks occurs at approximately 50% stance phase for both foot models at magnitudes of 0.900 times body weight for the arched foot and 0.905 times body weight for the flatfoot. These results are in close agreement with experimental studies from the literature [27, 49–55].
Fig 9

Vertical ground reaction forces.

The vertical ground reaction forces generated by simulations of the stance phase of gait with an arched foot (black) and a flatfoot (blue) model.

Vertical ground reaction forces.

The vertical ground reaction forces generated by simulations of the stance phase of gait with an arched foot (black) and a flatfoot (blue) model. The distribution of vertical ground reaction forces between the medial and lateral sides of the arched foot and flatfoot models are displayed in Fig 10. These force curves are separated into pairs of measurements: medial and lateral vertical ground reaction forces for each foot model. The medial split of vertical ground reaction forces was plotted as a sum of the vertical forces generated by the contact spheres on the head of the first metatarsal and the hallux. The lateral split of vertical ground reaction forces was plotted as a sum of the vertical forces generated by the contact spheres on the head of the fifth metatarsal and the fifth toe. The forces generated by the contact sphere on the heel were identical across the models and matched the magnitude and timing seen in a previous study [56].
Fig 10

Medial-lateral split of vertical ground reaction forces.

The medial/lateral split of vertical ground reaction forces generated by gait simulations using an arched foot (arched; black), flatfoot (FF; red), flatfoot with tendon transfer (FF+TT; blue), and flatfoot with implant-modified tendon transfer (FF+TT+I; green) model. The results are normalized by body weight (BW).

Medial-lateral split of vertical ground reaction forces.

The medial/lateral split of vertical ground reaction forces generated by gait simulations using an arched foot (arched; black), flatfoot (FF; red), flatfoot with tendon transfer (FF+TT; blue), and flatfoot with implant-modified tendon transfer (FF+TT+I; green) model. The results are normalized by body weight (BW). In the arched foot simulation, the medial and lateral vertical ground reaction forces peaked at 0.397 and 0.603 times body weight, respectively, which results in a 39.7%/60.3% medial/lateral split in peak vertical ground reaction forces. The flatfoot model generated peak medial and lateral vertical ground reaction forces of 0.493 and 0.507 times body weight, respectively, resulting in a 49.3%/50.7% medial/lateral split in peak vertical ground reaction forces. These medial/lateral splits in vertical ground reaction forces for the arched foot and flatfoot models were similar to those found in previous work [56-59]. Furthermore, these results indicate a 9.6% medial shift in peak vertical ground reaction forces between the arched foot model and the flatfoot model during the stance phase of gait, which agrees well with the 9.1% medial shift reported in an experimental study by Neville et al. with similar methodology [60].

Treatment comparison

Fig 10 also displays the medial/lateral split of vertical ground reaction forces over the stance phase of gait for the flatfoot with tendon transfer surgery and the flatfoot with implant-modified tendon transfer surgery models. Medial and lateral forces for the two treatment models were calculated in the same manner as described for the arched foot and flatfoot models. In the simulation using the flatfoot model with tendon transfer surgery, a 44.4%/55.6% medial/lateral split in peak vertical ground reaction forces was observed over the stance phase of gait. This distribution of vertical ground reaction forces indicates that the traditional tendon transfer surgery shifts foot plantar forces laterally by 3.9% when compared to no treatment (48.3%/51.7% medial/lateral split). The extent of restoration was calculated by dividing the lateral shift of ground reaction force found in the treatment model (3.9%) by the total medial shift of ground reaction force between the arched foot model and the flatfoot model (8.6%). Equivalently, these results represent a 45.3% restoration of the physiological medial/lateral distribution of vertical ground reaction forces generated by our arched foot model (39.7%/60.3% medial/lateral split). In the gait simulation using the flatfoot model with implant-based tendon transfer surgery, a 40.2%/59.8% medial/lateral split in peak vertical ground reaction forces was recorded. This 8.1% lateral shift in the distribution of vertical ground reaction forces from the untreated flatfoot model represents a 94.2% restoration of the physiologic medial/lateral distribution of vertical ground reaction forces generated by our arched foot model. Compared to the traditional tendon transfer model, the implant-based model provided 2.1X the restoration of the physiological vertical ground reaction force distribution. In the previous human cadaver experiment with the Robotic Gait Simulator, the center of pressure at the same percent stance phase (75%) was shifted laterally by 5.3% in the implant-based tendon transfer condition when compared to the flatfoot condition [11]. The increased restoration of the medial/lateral distribution of vertical ground reaction forces observed in our simulations compared to the experimental results can be attributed to the lack of soft tissue interactions and tendon friction in our idealized foot models.

Discussion

In this study, we created simplified biomechanical models in OpenSim of an arched foot, a flatfoot, a flatfoot with tendon transfer surgery, and a flatfoot with implant-modified tendon transfer surgery. Using a fixed-tibia and moving ground-plane simulation methodology, we evaluated the vertical ground reaction forces produced by each model on five contact points of the foot. The arched foot and flatfoot models have demonstrated the capability of reproducing the characteristic double-peak profile of vertical ground reaction forces during the stance phase of gait and each exhibit an appropriate medial/lateral distribution of these forces. The implant-modified tendon transfer model produced an 8.1% lateral shift in peak vertical ground reaction forces, resulting in a 94.2% restoration of the physiological medial/lateral distribution of vertical ground reaction forces observed in the arched foot model. This represents a 2.1X greater lateral shift of vertical ground reaction forces when compared to the traditional tendon transfer model (3.9% lateral shift). Adult acquired flatfoot deformity currently requires both a tendon transfer surgery and osteotomy to be fully corrective, with the primary purpose of correcting anatomical deformity and returning supporting forces to the foot arch, thereby restoring a physiological distribution of vertical ground reaction forces [1, 5–7, 11]. The long-term objective of this study is to develop a force-amplifying implant that provides additional surgical treatment options for patients with stage II adult acquired flatfoot deformity while maintaining or improving upon current patient outcomes. The 8.1% lateral shift of vertical ground reaction forces predicted by our implant-modified flatfoot model is promising when compared with computational models developed by Spratley et al. of surgical treatment for adult acquired flatfoot deformity [59]. Using complex rigid body models that incorporate soft tissue interactions, FDL tendon transfer surgery with medializing calcaneal osteotomy was simulated in flatfoot models, which found that the combined treatment provided a 9.0% increase in lateral forefoot loading force when compared to the untreated flatfoot model. Based on these results, the pulley-like implant used in this work demonstrates potential for amplifying the force produced by the transferred FDL and significantly shifting the distribution of vertical ground reaction forces more laterally when compared to current FDL tendon transfer surgeries without requiring an additional bony procedure. Thus, if a pulley-like implant could be used to create a FDL tendon network to better replicate physiological PT tendon forces, an additional osteotomy procedure may not be required to appropriately restore the foot arch in all cases of adult acquired flatfoot deformity requiring surgical intervention. A simpler surgery that does not require an additional bony procedure may help to provide additional surgical treatment options for adult acquired flatfoot deformity with stage II PT tendon dysfunction where a standard has yet to be established [5, 6, 61, 62]. The models developed in this work are differentiated from previous gait models because they preserve enough biomechanical and anatomical complexity to study how surgical treatments and varying pathology affect the distribution of vertical ground reaction forces during the stance phase of gait. While other models of human gait have been developed, they typically use ground reaction forces as an input to inverse dynamic simulation rather than generate it as an output. Many models are either too complex to dynamically simulate gait or too simple to enable anatomical modifications. More complex models that incorporate soft tissue interactions and passive ligaments of the foot are typically simulated with a static load rather than in dynamic gait due to the computational and time expense of doing so [23–25, 59]. Conversely, simple models can accurately reproduce ground reaction forces are often abstracted to the point that they lose anatomical definition [26-30]. The same simulation methodology presented here for adult acquired flatfoot deformity could also be modified and applied to other models of foot pathology, such as clubfoot, plantar fasciitis, and planovalgus [12, 55, 63–65], to evaluate treatment effectiveness through the ground reaction forces produced during gait. When compared with cadaveric or clinical studies, the time and effort efficiencies of biomechanical simulation provide an attractive alternative for initially evaluating the biomechanics of novel treatment options.

Limitations

While computational simulations can provide valuable information for evaluating the biomechanical feasibility of surgical treatment options, they also have inherent limitations. Specifically in biomechanics-focused simulations, certain critical biological processes cannot be modeled and accounted for. For example, we are not able to evaluate how scar tissue formation and tendon abrasion affect the long-term success of a translating pulley-like implant in tendon transfer surgery. Furthermore, the compensatory adaptations of muscles, tendons, and other tissues to adult acquired flatfoot deformity are not easily analyzed in simulation and were not included in this study. The differences in muscle force generation and excursion may ultimately have substantial impact on the efficacy of our implant-based tendon transfer procedure. To properly address these concerns, human cadaver studies of soft tissue interaction and live animal implantation studies of healing effects, rehabilitation, and implant biocompatibility must be conducted. Biomechanical simulations are also limited by computational complexity. Simplifying assumptions and model modifications must be made to run time-efficient simulations. However, the trade-off is that portions of complex human anatomy are oversimplified in the models, which limits the scope to which simulation results can be extrapolated to clinical settings. In our simplified foot models, implant interaction with soft tissue was completely neglected. Thus, while we may be able to describe a theoretical maximum force-amplification efficacy for our proposed implant, the definitive functional improvement provided by the implant in a clinical setting is still unclear. The contact between our foot models and the ground plane was also greatly simplified to enable reasonable simulation times and model complexity. Our foot models only have five distinct spheres of contact with the ground plane when in actuality the foot is in continuous contact with the ground during gait with infinite points of contact. Furthermore, the contact spheres retained a constant size and location between all four foot models even though medio-lateral plantar pressure distributions are expected to change before and after surgical intervention and due to anatomical variations [16, 56]. We also use a simplified arch joint in our foot models that removes significant complexity from the ligaments, muscles, and bones that form the actual medial longitudinal arch. These simplifications result in low-resolution foot-ground pressure data and potentially unrealistic arch interactions that prevent immediate claims of surgical treatment effectiveness. However, when solely comparing between the four models developed in this study that all use the same methodology, we can still make reasonable estimations on trends of medial/lateral vertical ground reaction force shifts between the different foot conditions and surgical treatment options. Other aspects of the proposed implant-based surgery can be examined in biomechanical simulation but were not explored in this work. Since we simulated the transferred FDL muscle path using the original routing of the PT, we assumed perfect tendon routing in tendon transfer surgery, which in reality has varying effects on tendon tensioning, tendon routing, and the active portion of the muscle force-length curve. We also used low resolution muscle force data, which makes it more difficult to accurately evaluate the continuous impact of surgical treatment on shifting the distribution of vertical ground reaction forces between the provided data points. Finally, we only evaluated a single, optimal configuration of the implant-based procedure. In reality, surgical decisions for the proposed implant-based procedure, such as the FDL tendon anchoring location and anchoring angle, must be made to optimize the effectiveness of the proposed treatment. These additional parameters can be explored in more detail in future biomechanical simulations.

Conclusions

The implant-based tendon transfer model and simulation developed in this work have demonstrated the biomechanical feasibility of a pulley-like implant to amplify the force produced by the the FDL in tendon transfer surgery for treatment of stage II adult acquired flatfoot deformity. If successfully developed, such an implant could potentially be applied to many other tendon transfer surgeries where muscle weakness is an issue, such as spinal cord injury, volumetric muscle loss, and peripheral nerve injury [9, 10, 66–70]. This implant has the potential to not only improve post-surgical outcomes for patients with muscle weakness but also to increase the patient population eligible for tendon transfer surgery. Since a grade of muscle strength is typically lost in tendon transfer procedures [71], donor muscles must meet minimum strength grade requirements to be considered for transfer. By effectively amplifying the muscle strength grade of the donor muscle, the implant could be indicated for patients with weaker candidate donor muscles to qualify for tendon transfer surgery. While these preliminary findings and potential applications are encouraging, there are many aspects of the proposed surgical procedure that need to be explored further to determine clinical feasibility of such a device. The implant must undergo additional evaluation both in biomechanical simulation and experimentally. Computational simulation can be utilzied to examine the unexplored biomechanical effects of suboptimal tendon routing, higher resolution muscle activation data, and variability in surgical technique. Studies in human cadavers and live animals will also be required to fully explore the effects of scar tissue formation, soft tissue interaction, and tendon abrasion on efficacy of the implant. (JPG) Click here for additional data file. 11 Jan 2021 PONE-D-20-33947 A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: validation using biomechanical simulation PLOS ONE Dear Dr. Ling, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. The reviewers have asked several methodological questions including model detail and validity.  Additionally, what are the clinical contraindications to this approach?   The PTT is often of significantly compromised quality, not the muscle, as others have reported including Dr. Deland.  This means that the tissue is incapable of sustained loading and would likely fail with the device you are designing. Further does scarring around the implant and/or tendon prevent tendon excursion to fully realize the mechanical advantage potentially provided by the device? Please submit your revised manuscript by Feb 25 2021 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: http://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols We look forward to receiving your revised manuscript. Kind regards, Jennifer S. Wayne Academic Editor PLOS ONE Journal Requirements: When submitting your revision, we need you to address these additional requirements. 1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf 2. We note that Figure 1 in your submission contains copyrighted images. All PLOS content is published under the Creative Commons Attribution License (CC BY 4.0), which means that the manuscript, images, and Supporting Information files will be freely available online, and any third party is permitted to access, download, copy, distribute, and use these materials in any way, even commercially, with proper attribution. For more information, see our copyright guidelines: http://journals.plos.org/plosone/s/licenses-and-copyright. We require you to either (1) present written permission from the copyright holder to publish these figures specifically under the CC BY 4.0 license, or (2) remove the figures from your submission: (1) You may seek permission from the original copyright holder of Figure 1 to publish the content specifically under the CC BY 4.0 license. We recommend that you contact the original copyright holder with the Content Permission Form (http://journals.plos.org/plosone/s/file?id=7c09/content-permission-form.pdf) and the following text: “I request permission for the open-access journal PLOS ONE to publish XXX under the Creative Commons Attribution License (CCAL) CC BY 4.0 (http://creativecommons.org/licenses/by/4.0/). Please be aware that this license allows unrestricted use and distribution, even commercially, by third parties. Please reply and provide explicit written permission to publish XXX under a CC BY license and complete the attached form.” Please upload the completed Content Permission Form or other proof of granted permissions as an "Other" file with your submission. In the figure caption of the copyrighted figure, please include the following text: “Reprinted from [ref] under a CC BY license, with permission from [name of publisher], original copyright [original copyright year].” (2) If you are unable to obtain permission from the original copyright holder to publish these figures under the CC BY 4.0 license or if the copyright holder’s requirements are incompatible with the CC BY 4.0 license, please either i) remove the figure or ii) supply a replacement figure that complies with the CC BY 4.0 license. Please check copyright information on all replacement figures and update the figure caption with source information. If applicable, please specify in the figure caption text when a figure is similar but not identical to the original image and is therefore for illustrative purposes only. 3. We noted in your submission details that a portion of your manuscript may have been presented or published elsewhere. ("Portions of the models and results of this paper have been presented in short abstracts at the American Society of Biomechanics conferences in 2016 and 2017. ") Please clarify whether this conference proceeding was peer-reviewed and formally published. If this work was previously peer-reviewed and published, in the cover letter please provide the reason that this work does not constitute dual publication and should be included in the current manuscript. 4. We note that you have stated that you will provide repository information for your data at acceptance. Should your manuscript be accepted for publication, we will hold it until you provide the relevant accession numbers or DOIs necessary to access your data. If you wish to make changes to your Data Availability statement, please describe these changes in your cover letter and we will update your Data Availability statement to reflect the information you provide. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Partly Reviewer #2: Partly ********** 2. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: N/A Reviewer #2: N/A ********** 3. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: Yes ********** 4. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 5. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: This study developed musculoskeletal models of the foot and ankle with the overall aim of assessing a newly proposed surgical intervention. My main concerns about the manuscript relate to the modeling process, with much more detail required here. Lines 7-9: Assuming you are using Johnson and Strom classification, this should be cited. Also, it should be clarified that at stage 2 the deformity is still flexible enough to be corrected Line 19: My understanding is that the osteotomy may also be required depending on how much flexibility there is in the deformity, in some cases it may not be a matter of being able to generate enough force Line 22: This paragraph could be clearer about what stage of development the proposed implant is at, from the following paragraph and the discussion it appears that it’s only been tested in a cadaver arm? Line 33-35: Note here that the pulley also reduces the range of motion of the muscle, it's not simply doubling the force for free Line 61: I'm not familiar with the term "foot's frontal axis"; I assume this refers to the sagittal plane of the foot? Lines 138-141: Not clear what the degrees of freedom of the new joints are and how they interact with the other segments? More detail required here. Line 149: What properties were used for the deltoid and spring ligaments? Lines 184-186: Limitation is that there are likely compensatory changes in the activity of other muscles in FF conditions, these are not accounted for Line 200: Did you try non-linear interpolation for these? The true activation patterns are unlikely to be linear between points Line 214: The RGS is limited to this speed by physical constraints, did you consider increasing the speed of your simulation back to normal? Line 221: Most simulations of the foot now use more complex models that can account for the non-linear viscoelastic behavior of the foot tissue. Line 225: Deformations are likely very different between sites on the foot Line 225-226: More details on this needed about this process. Was this a static simulation? This one of the key parts for tuning the models and how it was performed makes the validation data more or less externally convincing Line 229: Vs symbol different in the equation and definitions? And what value was used for Fv? Line 247-248: How did the AP and ML reaction forces look? Lines 280-290: I’m not sure how directly comparable measurements of plantar pressure are to the discrete contact spheres used in these models Reviewer #2: PONE-D-20-33947 - Review Ling, Hantao; Balasubramanian, Ravi “A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: validation using biomechanical simulation" Summary: The authors present an adapted rigid body model (OpenSim) of the human lower extremity in states representative of normal, flatfoot, and two reconstructed flatfoot states. They further elaborate on how the medial/lateral load distribution is changed between the model states under conditions simulating dynamic single-leg stance gait. The manuscript addresses a question with scientific merit and is well written. However, much detail is necessary to understand how the model was constituted and what assumptions were made with regard to the mechanics simulated. Finally, the study is more appropriately presented as an exploration of a potential new device. It is not clear what if any quantification is made of model biofidelity relative to the in vivo case. General Comments: 1. Model simplicity a. The OpenSim model is very simple and while segment geometry is visualized, it has no effect on joint function. This does not diminish potential model utility, but the predictive quality of the model should be contextualized relative to these simplifications b. The referenced OpenSim model is built to mimic normal lower extremity normal joint function. The appropriateness of using ‘normal’ joint and muscle definitions when simulating gross deformity should be included and contextualized i. STRUCTURE 1. The model is modified to mimic a flat foot arch by manually displacing the medial column segment of the model. This displacement is maintained through a torsional spring. It is not clear how this affects foot mechanics and no comparison to in vivo response is given. 2. More detail would help understanding how the path of the transferred ‘FDL’ was achieved. It seems that by using the existing PTT model elements and simply assigning it the force trajectory of the FDL, you have neglected any effects of routing. Is this correct? Why is this justified? 3. Needs figure of model a. Why constrained to sagittal? ii. TENDON 1. the muscle curves are directly applied as force, which assumes that not only is the activation unchanged but that the structural deformity (with accompanying tendon rerouting & length changes) has no effect on the force generated at a given % of the stance phase. Is it reasonable / useful to use these ‘normal’ inputs for this deformed case? Please justify. iii. MUSCLE 1. The in vivo muscles have finite contraction lengths which are proportional to the number of sarcomeres in series in the muscle belly. While these can remodel to accommodate within limited ranges to effect new contractile lengths, the overall contraction length of the FDL is relatively constant. The pully mechanism incorporated does indeed have the effect of doubling force output… but it does so at the expense of halving the excursion of the tendon. 2. It is not clear that this limitation is reflected in the model 3. It is not clear that the full dorsiflexion �  plantar flexion ROM would be achievable if the effective excursion of the tendon were halved 2. Much more detail is needed on the model. While some details can be obtained through the provided OpenSim references, much more is needed to explain HOW the model is used: a. For example, the boundary conditions assigned to the model and which parameters were driven, which were reported, which if any were used in the control of the platform (this is done in the referenced robotic cadaver work… was it similarly implemented in the model?), which joint degrees of freedom were allowed and at what locations, what are the stiffnesses and permitted ranges of those joints, etc. b. How are the inertial properties of the limb implemented and at what rate are the motions simulated? i. In particular, it is not clear how the axial force of the model was implemented during the simulation. The initial position seemed to be tuned by incrementally lowering the vertical plantar surface of the foot toward loading platform until the reaction force generated by the sphere/platform penetration was approximately equal to BW. After initial positioning though it is not clear what was done. 1. Since it is referenced as a forward dynamics simulation, presumably there is a dynamic axial force and the vertical displacement is free to change in order to maintain equilibrium. Is this correct? ii. The characteristic bimodal shape of the GRF curve captured for living subjects is the result of deceleration of their body mass at heel strike and acceleration during toe off. Here the subject body mass doesn’t change in time during stance phase and rate of loading is critical. Due to the significant technical challenges with control and instability many (all?) forward dynamics experimental and model simulations that I’m aware of are typically executed much slower than what is reflected in the GRF curves in Fig 8. c. The above comments (a,b) are relevant because the GRF is reported as an output and used as demonstration of the models’ fidelity. However, it seems that this is perhaps a controlled input. *IF* that is the case, its agreement is simply verification of the inputs and should not be used as part of the objective scoring of the model. 3. Validation versus exploration a. The model provides useful insight into flatfoot function and the mechanics of how tendon transfer reconstructions may work b. However, it is not clear what reference human or cadaver data is presented and how the model biofidelity is scored relative to it. i. See above comments with regard to the use of GRF ii. Figure 9 shows the sensitivity of the model to incorporation of the TT and TT+I. However, the reference normal (Black & Black Dashed) lines are also from the simulation. It is not clear how claims of biofidelity are judged here since all comparisons are between states of the same model under review. 1. The magnitude of changes (medial load shifted to lateral) should be discussed relative to those reported in the literature for human or cadaveric experiments. References should be expanded to include such prior work. Specific Comments: 181-183 Exploring *all* the sensitivities of the model is perhaps out of scope. However, to say that *any* exploration of sensitivity is out of scope is not reasonable. The work may show the promise of the technique but claims that the model is ‘validated’ are overstated. 224-225 This is the first mention of the any soft-tissue element in the model. How was the footpad implemented? Were there any other soft tissues (e.g., skin, fat, muscle, etc.?) If the full mass of soft tissues were not incorporated, how were the limbs inertial properties approximated? 237-238 Additional detail regarding how contact sphere diameter was derived from studies of foot shape 344-345 See General Comment 2. Detail should be added to Methods to elaborate on this point. Figure Comments FIG3 Suggest elaborating/expanding this figure with detail about the segments, joints, and contact spheres. FIG4 This figure spot may be better used as a place to show the specifics of the device and resulting tendon routing in the various model states FIG5 Label the subplots B,C to reflect they are input kinematics FIG8 Caption Denote that the black line is experimental data(?) (cadaver or human subject) FIG# A simulation matrix would help in showing what was simulated and what model attributes were changed to represent a given state ********** 6. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. Submitted filename: PONE-D-20-33947 - Review.pdf Click here for additional data file. 3 Aug 2021 The Response to Reviewers is attached as a PDF in the submission. Submitted filename: Response to Reviewers.pdf Click here for additional data file. 3 Aug 2021 PONE-D-20-33947R1 A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: evaluating feasibility in biomechanical simulation Dear Dr. Ling, The above-mentioned manuscript has now been withdrawn from the review process at PLOS ONE. If this was a mistake, please do reach out to us at plosone@plos.org. Otherwise, no further action is needed from you at this point. Sincerely, PLOS ONE 13 Sep 2021 The response to the reviewers is attached in the 'Response to Reviewers.pdf' file included in this submission. Submitted filename: Response to Reviewers.pdf Click here for additional data file. 25 May 2022
PONE-D-20-33947R2
A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: evaluating feasibility in biomechanical simulation PLOS ONE Dear Dr. Ling, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Jul 09 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript: A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.
If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Amarjit Singh Virdi, PhD Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed Reviewer #3: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #3: Partly ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #3: N/A ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #3: Yes ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #3: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: The authors have addressed all of my comments in this much improved manuscript. Congratulations on an interesting study. Reviewer #3: The authors have addressed most of the comments in the previous round of review. Several minor revisions are necessary. Related to comments by previous reviewers: Both reviewers made comments that the intervention potentially reduces the range-of-motion (ROM) of the muscle (Reviewer 1) and the ankle joint (Reviewer 2). The authors revised and explained well why such an excursion trade-off is necessary to generate force that is 2X than what the FDL muscle is capable of. They also clarified that the full ROM from dorsiflexion to plantarflexion was simulated. The simulated ROM was passive (produced by the moving ground plate), while the previous reviewers’ comments seem to concern the active ROM. The authors are recommended to discuss the potential effect or limitation on ROM to directly address the reviewers’ comments. Reviewer 2 suggested to clarify inputs and outputs of the simulation and what reference human or cadaver data is presented. The authors revised by including additional references. Citation 35, 36, and 37 show that the RGS has been used to simulate physiological and pathological gait. By reviewing citation 11, the kinematics of the moving ground plate seems to come from the experimental data (output), which was generated by that tibia to ground kinematics of healthy participants and experimentally induced flat foot models (inputs). I understand it is difficult to classify whether the ground plate kinematics is physiological or pathological. What about the EMG estimates (line 252-254)? Do they come from healthy participants or not (line 252-254; citation 35, 42, 43)? If the data come from pathological population, what exactly are the pathologies? Additional comments by current reviewer: The same dimension of contact spheres were used for all four foot models. However, as suggested by citation 16 and 56, medio-lateral plantar pressure distribution can change before and after surgical intervention and between individuals presenting anatomical variations. This limitation is suggested to be discussed like the other model simplicity limitations (e.g., compensatory muscle activations). The medial and lateral vertical ground reaction force in lines 385-395 do not completely match what are shown on figure 10. For example, in text, the arched foot showed medial and lateral 0.454 and 0.691 N/BW, respectively. However, on the figure, the respective medial and lateral peaks are about 0.4 and 0.6. Line 46-50 regarding excursion trade-off may be moved and combined with lines 233-237. Line 40-42 “…amplify the force transferred from the weaker FDL to the PT [tendon]” Figure 8 in text shows gait events sequentially from left to right. It would be an improvement if a left lower leg is shown as compared to a right leg, allowing readers to visualize the foot proceeding the stance phase of gait from left to right. However, I understand that the authors might intend to show the medial side of the foot. In summary, the revision includes additional information, addressing most of the suggestions by the previous reviewers. With the suggested minor revisions, the manuscript would be a sound piece of scientific research and recommended to be accepted by the journal. ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #3: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.
8 Jun 2022 The reviewer response is provided in the 'Response to Reviewers.pdf' document. Submitted filename: Response to Reviewers.pdf Click here for additional data file. 15 Jun 2022 A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: evaluating feasibility in biomechanical simulation PONE-D-20-33947R3 Dear Dr. Ling, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Amarjit Singh Virdi, PhD Academic Editor PLOS ONE Additional Editor Comments (optional): Thank you for your prompt response to the reviewer's comments which improved (and corrected) the manuscript for the readers. Reviewers' comments: 17 Jun 2022 PONE-D-20-33947R3 A novel implantable mechanism-based tendon transfer surgery for adult acquired flatfoot deformity: evaluating feasibility in biomechanical simulation Dear Dr. Ling: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Amarjit Singh Virdi Academic Editor PLOS ONE
  63 in total

1.  THE ROLE OF MUSCLES IN ARCH SUPPORT OF THE FOOT.

Authors:  J V BASMAJIAN; G STECKO
Journal:  J Bone Joint Surg Am       Date:  1963-09       Impact factor: 5.284

Review 2.  Tibialis posterior dysfunction: a common and treatable cause of adult acquired flatfoot.

Authors:  Julie Kohls-Gatzoulis; John C Angel; Dishan Singh; Fares Haddad; Julian Livingstone; Greg Berry
Journal:  BMJ       Date:  2004-12-04

3.  OpenSim: open-source software to create and analyze dynamic simulations of movement.

Authors:  Scott L Delp; Frank C Anderson; Allison S Arnold; Peter Loan; Ayman Habib; Chand T John; Eran Guendelman; Darryl G Thelen
Journal:  IEEE Trans Biomed Eng       Date:  2007-11       Impact factor: 4.538

4.  Contributions of the soleus and gastrocnemius muscles to the anterior cruciate ligament loading during single-leg landing.

Authors:  Hossein Mokhtarzadeh; Chen Hua Yeow; James Cho Hong Goh; Denny Oetomo; Fatemeh Malekipour; Peter Vee-Sin Lee
Journal:  J Biomech       Date:  2013-06-02       Impact factor: 2.712

Review 5.  Operative management options for symptomatic flexible adult acquired flatfoot deformity: a review.

Authors:  Htwe Zaw; James D F Calder
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02       Impact factor: 4.342

6.  Battlefield orthopaedic injuries cause the majority of long-term disabilities.

Authors:  Jessica D Cross; James R Ficke; Joseph R Hsu; Brendan D Masini; Joseph C Wenke
Journal:  J Am Acad Orthop Surg       Date:  2011       Impact factor: 3.020

7.  An actuated dissipative spring-mass walking model: Predicting human-like ground reaction forces and the effects of model parameters.

Authors:  Tong Li; Qingguo Li; Tao Liu
Journal:  J Biomech       Date:  2019-05-06       Impact factor: 2.712

8.  Force-deformation properties of the human heel pad during barefoot walking.

Authors:  Scott C Wearing; Sue L Hooper; Philip Dubois; James E Smeathers; Albrecht Dietze
Journal:  Med Sci Sports Exerc       Date:  2014-08       Impact factor: 5.411

9.  A Dynamic Optimization Solution for Vertical Jumping in Three Dimensions.

Authors:  FRANK C. Anderson; MARCUS G. Pandy
Journal:  Comput Methods Biomech Biomed Engin       Date:  1999       Impact factor: 1.763

10.  The Foot's Arch and the Energetics of Human Locomotion.

Authors:  Sarah M Stearne; Kirsty A McDonald; Jacqueline A Alderson; Ian North; Charles E Oxnard; Jonas Rubenson
Journal:  Sci Rep       Date:  2016-01-19       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.