Literature DB >> 36151400

Molecularly imprinted polymer specific to creatinine complex with copper(II) ions for voltammetric determination of creatinine.

Taher Alizadeh1, Zahrasadat Mousavi2.   

Abstract

Synthesis of creatinine-imprinted polymer is challenging because of its insolubility in aprotic solvents, traditionally utilized for synthesizing molecularly imprinted polymer (MIP). Moreover, creatinine is not electroactive at conventional electrodes, and thus, introducing an electrochemical sensing platform for its determination is a difficult target. This study addressed the above-cited issues to introduce a novel creatinine voltammetric sensor with high selectivity and sensitivity. Creatinine-copper complex was found to be soluble in acetonitrile and was utilized as a template for the MIP synthesis. Methacrylic acid, ethylene glycol dimethacrylate, and azobisisobutyronitrile were used as functional monomers, cross-linker, and initiator, respectively. The MIP holding creatinine sites were used to modify the carbon paste electrode. Since creatinine did not exhibit a significant voltammetric signal, an indirect sensing technique was employed. This was based on using Cu(II) ion as an electrochemical probe. The MIP-modified electrode signal for copper ion was significantly improved in the presence of creatinine. However, the introduction of creatinine in the Cu(II) solution did not affect the NIP-modified electrode response to copper ion. The proposed sensor indicated a linear current response in the range 1 × 10-7-1 × 10-5 mol L-1 with a detection limit of 5.9 × 10-8 mol L-1 (S/N = 3). Moreover, this method presents excellent performance in real sample analysis, with values of favorable creatinine recovery in plasma. The system exhibits acceptable precision (RSD = 4.04) and favorable selectivity toward creatinine.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.

Entities:  

Keywords:  Creatinine; Cu complex; Imprinted polymer; Nanosensor; Plasma analysis; Voltammetry

Mesh:

Substances:

Year:  2022        PMID: 36151400     DOI: 10.1007/s00604-022-05470-8

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   6.408


  22 in total

1.  A novel structural specific creatinine sensing scheme for the determination of the urine creatinine.

Authors:  Chi-Hao Chen; Meng Shan Lin
Journal:  Biosens Bioelectron       Date:  2011-10-06       Impact factor: 10.618

Review 2.  How to estimate GFR-serum creatinine, serum cystatin C or equations?

Authors:  Stefan Herget-Rosenthal; Arend Bökenkamp; Walter Hofmann
Journal:  Clin Biochem       Date:  2006-11-21       Impact factor: 3.281

Review 3.  Creatinine biosensors: principles and designs.

Authors:  A J Killard; M R Smyth
Journal:  Trends Biotechnol       Date:  2000-10       Impact factor: 19.536

4.  Estimation of creatinine by the Jaffe reaction. A comparison of three methods.

Authors:  H Husdan; A Rapoport
Journal:  Clin Chem       Date:  1968-03       Impact factor: 8.327

5.  Plasma creatinine determination. A new and specific Jaffe reaction method.

Authors:  C Slot
Journal:  Scand J Clin Lab Invest       Date:  1965       Impact factor: 1.713

6.  Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum.

Authors:  T Tsuchida; K Yoda
Journal:  Clin Chem       Date:  1983-01       Impact factor: 8.327

7.  Preparation of a novel molecularly imprinted polymer by the sol-gel process for sensing creatinine.

Authors:  Ta-Jen Li; Po-Yen Chen; Po-Chin Nien; Chia-Yu Lin; R Vittal; Tzong-Rong Ling; Kuo-Chuan Ho
Journal:  Anal Chim Acta       Date:  2011-11-03       Impact factor: 6.558

Review 8.  A review on creatinine measurement techniques.

Authors:  Elham Mohabbati-Kalejahi; Vahid Azimirad; Manouchehr Bahrami; Ahmad Ganbari
Journal:  Talanta       Date:  2012-04-25       Impact factor: 6.057

9.  Variation of serum creatinine, cystatin C, and creatinine clearance tests in persons with normal renal function.

Authors:  John G Toffaletti; Elizabeth H McDonnell
Journal:  Clin Chim Acta       Date:  2008-06-03       Impact factor: 3.786

Review 10.  Creatinine: a review.

Authors:  S Narayanan; H D Appleton
Journal:  Clin Chem       Date:  1980-07       Impact factor: 8.327

View more