| Literature DB >> 36132196 |
Chun-Yan Wang1, Yan Zhou1, Yu-Yuan Ren2, Yu-Shuang Luan3, Zhong-Cai Jiang2, Zhi-Xing Wang1.
Abstract
Objective: The objective of the study is to analyze the influencing factors on the results of thyroid fine-needle aspiration biopsy (FNAB). Method: A total of 339 patients who underwent FNAB in our hospital from December 2018 to July 2021 were retrospectively selected. The patients were chosen according to the gender ratio, age, and thyroid ultrasound characteristics and were divided into three groups: (1) a 22G needle vacuum aspiration group (Group 1, n = 85), (2) a 22G biopsy needle non-vacuum aspiration group (Group 2, n = 50), and (3) a 25G biopsy needle non-vacuum aspiration group (Group 3, n = 204). Patients in these groups were evaluated for determining the FNAB dissatisfaction rate of pathological samples. A bivariate regression analysis of independent risk factors related to the unsatisfactory pathological diagnosis of samples was performed.Entities:
Keywords: biopsy; capillary; cytology; needle; thyroid nodule; ultrasonography
Year: 2022 PMID: 36132196 PMCID: PMC9483012 DOI: 10.3389/fsurg.2022.907086
Source DB: PubMed Journal: Front Surg ISSN: 2296-875X
The Bethesda system for reporting thyroid cytopathology (TBSRTC).
| Category | Clinical significance | Risk of malignancy (%) |
|---|---|---|
| Category I, TBSRTC | Non-diagnosable or unsatisfactory specimens | 1–4 |
| Category II, TBSRTC | Benign follicular nodules | 0–3 |
| Category III, TBSRTC | Atypical cells of uncertain significance | 5–15 |
| Category IV, TBSRTC | Follicular tumor or suspected follicular tumor | 15–30 |
| Category V, TBSRTC | Suspected malignant tumor | 60–75 |
| Category VI, TBSRTC | Malignant tumor | 97–99 |
Comparison between the two groups in terms of general clinical conditions and thyroid ultrasound features (x ± s).
| Group | Group 1 | Group 2 | Group 3 | |
|---|---|---|---|---|
| 21/64 | 10/40 | 48/156 | 0.817 | |
| Age (Years) | 48.35 ± 13.48 | 50.80 ± 13.97 | 46.15 ± 13.27 | 0.067 |
| TSH (uiu/ml) | 1.94 ± 1.22 | 1.93 ± 1.39 | 2.08 ± 1.18 | 0.628 |
| Nodule size (cm) | 1.32 ± 0.87 | 1.01 ± 0.96 | 1.07 ± 0.79 | 0.049 |
| Nodule blood flow (no/little/abundant) | 18/43/24 | 18/23/9 | 63/106/35 | 0.139 |
| Nodule type (solid/solid-cystic) | 72/13 | 44/6 | 188/16 | 0.15 |
| Aspect ratio greater than 1 (case) | 18/85 | 22/50 | 73/204 | 0.012 |
| Calcification (case) (no/tiny/thick) | 42/26/17 | 19/22/9 | 94/84/26 | 0.253 |
Group 1: Vacuum aspiration with 22G injection needle; Group 2: Capillary siphoning with 22G biopsy needle; Group 3: Capillary siphoning with 25G biopsy needle.
Comparison between different capillary sampling needles and aspiration methods in terms of cytopathological satisfaction of thyroid fine-needle aspiration biopsy (FNAB).
| Pathological results | Group 1 | Group 2 | Group 3 | Chi-square value | |
|---|---|---|---|---|---|
| Satisfactory puncture results | 63 | 35 | 186 | 21.04 | <0.001 |
| Unsatisfactory puncture results | 22 | 15 | 18 |
Group 1: Vacuum aspiration with 22G injection needle; Group 2: Capillary sampling with 22G biopsy needle; Group 3: Capillary sampling with 25G biopsy needle.
Logistic regression analysis of independent risk factors for unsatisfactory thyroid FNAB pathological results.
| Index |
| SE( | Wald– |
| OR | 95% CI |
|---|---|---|---|---|---|---|
| Age | −0.55 | 0.013 | 16.64 | <0.001 | 0.95 | 0.92–0.97 |
| Gender | 0.431 | 0.405 | 1.132 | .287 | 1.54 | 0.70–3.41 |
| Nodule size | −0.086 | 0.225 | 0.144 | 0.704 | 0.918 | 0.590–1.428 |
| Nodule location | 0.373 | 0.350 | 1.137 | 0.286 | 1.452 | 0.731–2.884 |
| Nodule blood flow | 0.080 | 0.274 | 0.086 | 0.769 | 1.084 | 0.634–1.853 |
| Nodular aspect ratio | 0.086 | 0.406 | 0.045 | 0.833 | 1.090 | 0.492–2.415 |
| Nodule morphology | 0.667 | 0.451 | 2.187 | 0.139 | 1.948 | 0.805–4.713 |
| Nodule border | −0.663 | 0.401 | 2.731 | 0.098 | 0.515 | 0.235–1.131 |
| Nodule calcification | −0.245 | 0.264 | 0.861 | 0.354 | 0.783 | 0.466–1.314 |
| TSH level | −0.041 | 0.149 | 0.077 | 0.781 | 0.960 | 0.717–1.285 |
| Capillary sampling needles and aspiration methods | 0.699 | 0.196 | 12.74 | <0.001 | 2.03 | 1.37–2.99 |
OR, odds ratio.